Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:59:18 on May 31, 2008

    Entry number 240551

    keyword=End_of_Run_1762
    ****************************
     Run Number: 1762
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=kin 8 delta -2
     
    
    PRESCALE FACTORS:ps1=4000   ps2=16777215   ps3=200   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5002096      [+]: 2460392      [-]: 2467932      
    TIME     : [0]: 61.542 mins  [+]: 30.352 mins  [-]: 30.347 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.73546 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  27.18%      [+]:  27.24%      [-]:  27.33%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.3/69310.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :17.8/3551.9 Hz   T4[0] : 8.2/16398.2 Hz   T5[0] :1816.6/1816.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.3/69195.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :17.7/3544.9 Hz   T4[+] : 8.2/16373.1 Hz   T5[+] :1813.0/1813.0 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.4/69449.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :17.8/3560.1 Hz   T4[-] : 8.2/16428.7 Hz   T5[-] :1821.2/1821.2 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  63982/255929496  T2[0] :      0/0        T3[0] :  65576/13115274  T4[0] :  30275/60550318  T5[0] :6707816/6707816  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  37811/3781129  
    T1[+] :  31503/126015573  T2[+] :      0/0        T3[+] :  32278/6455766  T4[+] :  14908/29817805  T5[+] :3301646/3301646  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  18648/1864850  
    T1[-] :  31613/126455730  T2[-] :      0/0        T3[-] :  32412/6482411  T4[-] :  14956/29913956  T5[-] :3316065/3316065  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  18645/1864530  
    
    AVERAGE CURRENT
    BCM x1 : 17.6140uA  BCM x3 : 17.6130uA  BCM x10: 8.8377 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1925 ppm     BCM u3 :    -1872 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1932 ppm     BCM d3 :    -1847 ppm     BCM d10:    -1861 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06528        BCM u3 [0]:0.06529        BCM u10[0]:-6.868E-05     
    BCM u1 [+]:0.03214        BCM u3 [+]:0.03215        BCM u10[+]:-3.387E-05     
    BCM u1 [-]:0.03226        BCM u3 [-]:0.03226        BCM u10[-]:-3.387E-05     
    
    BCM d1 [0]:0.0648         BCM d3 [0]:0.06478        BCM d10[0]:0.06534        
    BCM d1 [+]:0.0319         BCM d3 [+]:0.0319         BCM d10[+]:0.03217        
    BCM d1 [-]:0.03202        BCM d3 [-]:0.03201        BCM d10[-]:0.03228        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1762 at Sat May 31 14:59:09 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.931328
    Left Arm arm angle : 43.4997
    Right Arm D1 momentum : 0.00438994
    Right Arm arm angle : 0.197
    HALLA:p : 1192.11
    HALLA:dpp : -0.000230672
    Tiefenbach Hall A energy : 1192.11
    Left Arm Top VDC Current : -0.585938
    Left Arm Bottom VDC Current : -0.976562
    -----
    Left Arm Q1 momentum : 0.931435
    Left Arm Q1 power supply : 700.694
    Left Arm Q1 gauss meter : 0.0598
    Left Arm Q2 gauss meter : -0.2111
    Left Arm Q2 power supply current : 401.055
    Left Arm Q2 momentum : 0.931387
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 310.713
    Left Arm D1 momentum : 0.931328
    Left Arm D1 NMR : 0.392307
    Left Arm Q3 gauss meter : 0.188672
    Left Arm Q3 power supply current : 370.701
    Left Arm Q3 momentum : 0.931131
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00397137
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.49e-05
    Right Arm Q2 power supply current : -0.000210751
    Right Arm Q2 momentum : -4.89701e-07
    Right Arm Q2 gauss meter : -0.0002998
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0272064
    Right Arm D1 momentum : 0.00440138
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000160661
    Right Arm Q3 momentum : 0.000189746
    Right Arm Q3 gauss meter : -0.000266
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5638
    -----
    Average current of the two cavities : 21.0214
    Current on Unser monitor : 32.507
    Current on Upstream bcm : 20.7893
    Current on Downstream bcm : 21.2534
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 92.4478
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.12
    Hall A momentum orbit correction (dpp) : -0.000220917
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.12
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.22674
    IPM1C12.XPOS : 0.877672
    IPM1H04A.XPOS : -1.13443
    IPM1H04A.YPOS : 1.16119
    IPM1H04B.XPOS : -1.80356
    IPM1H04B.YPOS : 1.92999
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.249512
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.251465
    -----
    Right Arm Collimator : -0.0081543
    HacR_HPE1313A:0_Ch58 : -0.568848
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.84668
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 182
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.447205
    SLI vert. size mm : 0
    SLI y position : 0.495775
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.8
    temperature loop 1(2) : 100.43
    temperature loop 1(3) : 95.47
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.1
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.114237
    HPH H2 loop 3 : 63.5209
    -----