Run Number: 1764
End of Run Comment:
Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=kin 8 delta -2
PRESCALE FACTORS:ps1=4000 ps2=16777215 ps3=200 ps4=2000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 5004761 [+]: 2460693 [-]: 2470299
TIME : [0]: 57.536 mins [+]: 28.378 mins [-]: 28.374 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -7.45939 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 27.34% [+]: 27.38% [-]: 27.48%
TRIGGER RATES: PRES/REAL
T1[0] :18.7/74651.7 Hz T2[0] : 0.0/0.0 Hz T3[0] :19.0/3805.7 Hz T4[0] : 8.8/17520.4 Hz T5[0] :1949.0/1949.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :18.6/74517.6 Hz T2[+] : 0.0/0.0 Hz T3[+] :19.0/3797.6 Hz T4[+] : 8.7/17491.9 Hz T5[+] :1943.9/1943.9 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] :18.7/74802.5 Hz T2[-] : 0.0/0.0 Hz T3[-] :19.1/3814.6 Hz T4[-] : 8.8/17553.3 Hz T5[-] :1954.7/1954.7 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 64427/257708239 T2[0] : 0/0 T3[0] : 65688/13137717 T4[0] : 30241/60482911 T5[0] :6728376/6728376 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 35349/3534992
T1[+] : 31719/126879818 T2[+] : 0/0 T3[+] : 32330/6466182 T4[+] : 14891/29783080 T5[+] :3309913/3309913 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 17435/1743546
T1[-] : 31836/127346484 T2[-] : 0/0 T3[-] : 32470/6494119 T4[-] : 14941/29883408 T5[-] :3327736/3327736 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 17432/1743295
AVERAGE CURRENT
BCM x1 : 18.9183uA BCM x3 : 18.9172uA BCM x10: 9.4930 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1972 ppm BCM u3 : -1918 ppm BCM u10: 1E+39 ppm
BCM d1 : -1978 ppm BCM d3 : -1892 ppm BCM d10: -1907 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.06554 BCM u3 [0]:0.06555 BCM u10[0]:-6.422E-05
BCM u1 [+]:0.03227 BCM u3 [+]:0.03227 BCM u10[+]:-3.168E-05
BCM u1 [-]:0.03239 BCM u3 [-]:0.03239 BCM u10[-]:-3.167E-05
BCM d1 [0]:0.06507 BCM d3 [0]:0.06506 BCM d10[0]:0.06561
BCM d1 [+]:0.03204 BCM d3 [+]:0.03203 BCM d10[+]:0.0323
BCM d1 [-]:0.03216 BCM d3 [-]:0.03215 BCM d10[-]:0.03242
****************************
End-of-run EPICS data for Run Number 1764 at Sat May 31 16:58:25 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.931328
Left Arm arm angle : 43.4997
Right Arm D1 momentum : 0.0044022
Right Arm arm angle : 0.197
HALLA:p : 1192.12
HALLA:dpp : -0.000217653
Tiefenbach Hall A energy : 1192.12
Left Arm Top VDC Current : 4.24805
Left Arm Bottom VDC Current : 4.00391
-----
Left Arm Q1 momentum : 0.931435
Left Arm Q1 power supply : 700.694
Left Arm Q1 gauss meter : 0.05981
Left Arm Q2 gauss meter : -0.2111
Left Arm Q2 power supply current : 401.055
Left Arm Q2 momentum : 0.931386
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 310.709
Left Arm D1 momentum : 0.931328
Left Arm D1 NMR : 0.392307
Left Arm Q3 gauss meter : 0.188659
Left Arm Q3 power supply current : 370.702
Left Arm Q3 momentum : 0.931133
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00394486
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -9.44e-05
Right Arm Q2 power supply current : -0.000251423
Right Arm Q2 momentum : -4.98293e-07
Right Arm Q2 gauss meter : -0.0002997
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0289856
Right Arm D1 momentum : 0.00439866
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -4.10994e-05
Right Arm Q3 momentum : 0.000189186
Right Arm Q3 gauss meter : -0.0002662
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.5634
-----
Average current of the two cavities : 20.8564
Current on Unser monitor : 31.8531
Current on Upstream bcm : 20.4192
Current on Downstream bcm : 21.2936
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 92.1185
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.12
Hall A momentum orbit correction (dpp) : -0.000223618
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.12
Hall C energy (hallc_MeV) : 5710.94
Delta(E)/E width (MV_AI_DXWID) : 1.2225
IPM1C12.XPOS : 0.85588
IPM1H04A.XPOS : -1.12992
IPM1H04A.YPOS : 1.1051
IPM1H04B.XPOS : -1.79955
IPM1H04B.YPOS : 1.86002
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.248535
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.251465
-----
Right Arm Collimator : -0.00805664
HacR_HPE1313A:0_Ch58 : -0.568848
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.847656
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 183
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.65466
SLI vert. size mm : 0
SLI y position : 0.901408
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 100.91
temperature loop 1(2) : 100.53
temperature loop 1(3) : 95.61
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.2
Heat exchange LH2 : 20.1
HPH H2 loop 1 : 0.0970926
HPH H2 loop 3 : 63.5209
-----