Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:13:50 on May 31, 2008

    Entry number 240564

    keyword=End_of_Run_1766
    ****************************
     Run Number: 1766
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=kin 8 delta -2
     
    
    PRESCALE FACTORS:ps1=4000   ps2=16777215   ps3=200   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5001631      [+]: 2460232      [-]: 2467287      
    TIME     : [0]: 65.075 mins  [+]: 32.090 mins  [-]: 32.092 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.99685 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  26.77%      [+]:  26.83%      [-]:  26.91%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.3/65297.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.7/3338.1 Hz   T4[0] : 7.8/15599.8 Hz   T5[0] :1707.5/1707.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :16.3/65188.5 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.7/3333.1 Hz   T4[+] : 7.8/15577.6 Hz   T5[+] :1704.5/1704.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :16.4/65442.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.7/3344.7 Hz   T4[-] : 7.8/15629.2 Hz   T5[-] :1711.1/1711.1 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  63738/254954576  T2[0] :      0/0        T3[0] :  65168/13033612  T4[0] :  30454/60909372  T5[0] :6666810/6666810  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  39982/3998203  
    T1[+] :  31378/125512604  T2[+] :      0/0        T3[+] :  32087/6417504  T4[+] :  14996/29992820  T5[+] :3281864/3281864  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  19715/1971589  
    T1[-] :  31502/126008695  T2[-] :      0/0        T3[-] :  32201/6440272  T4[-] :  15047/30094069  T5[-] :3294761/3294761  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  19717/1971710  
    
    AVERAGE CURRENT
    BCM x1 : 16.6252uA  BCM x3 : 16.6245uA  BCM x10: 8.3429 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1867 ppm     BCM u3 :    -1812 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1872 ppm     BCM d3 :    -1788 ppm     BCM d10:    -1800 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06513        BCM u3 [0]:0.06514        BCM u10[0]:-7.262E-05     
    BCM u1 [+]:0.03207        BCM u3 [+]:0.03207        BCM u10[+]:-3.581E-05     
    BCM u1 [-]:0.03219        BCM u3 [-]:0.03219        BCM u10[-]:-3.581E-05     
    
    BCM d1 [0]:0.06469        BCM d3 [0]:0.06468        BCM d10[0]:0.06522        
    BCM d1 [+]:0.03185        BCM d3 [+]:0.03185        BCM d10[+]:0.03211        
    BCM d1 [-]:0.03197        BCM d3 [-]:0.03196        BCM d10[-]:0.03223        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1766 at Sat May 31 18:13:40 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.931329
    Left Arm arm angle : 43.4997
    Right Arm D1 momentum : 0.00435315
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 3.17383
    Left Arm Bottom VDC Current : 3.32031
    -----
    Left Arm Q1 momentum : 0.931435
    Left Arm Q1 power supply : 700.748
    Left Arm Q1 gauss meter : 0.0598
    Left Arm Q2 gauss meter : -0.2111
    Left Arm Q2 power supply current : 401.055
    Left Arm Q2 momentum : 0.931386
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 310.709
    Left Arm D1 momentum : 0.931329
    Left Arm D1 NMR : 0.392307
    Left Arm Q3 gauss meter : 0.188613
    Left Arm Q3 power supply current : 370.702
    Left Arm Q3 momentum : 0.931135
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00503712
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001229
    Right Arm Q2 power supply current : -0.000207054
    Right Arm Q2 momentum : -4.8111e-07
    Right Arm Q2 gauss meter : -0.0002933
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0268605
    Right Arm D1 momentum : 0.00435315
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 3.36267e-05
    Right Arm Q3 momentum : 0.000189186
    Right Arm Q3 gauss meter : -0.0002661
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5637
    -----
    Average current of the two cavities : 0.0252385
    Current on Unser monitor : 12.7169
    Current on Upstream bcm : 0.0350416
    Current on Downstream bcm : 0.0154353
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00924622
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.248535
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : -0.251465
    -----
    Right Arm Collimator : -0.00810547
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.846191
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 75
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.25963
    SLI vert. size mm : 0
    SLI y position : 1.41972
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.95
    temperature loop 1(2) : 100.57
    temperature loop 1(3) : 95.89
    temperature loop 3(1) : 19.97
    temperature loop 3(2) : 19.96
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.2
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 87.4018
    -----