NEXT
User name a-onl
Log entry time 19:48:18 on May 31, 2008
Entry number 240572
keyword=End_of_Run_1768
****************************
Run Number: 1768
End of Run Comment:
Run_type=Calibration,target_type=Al Dummy,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=AL Dummy Run
PRESCALE FACTORS:ps1=4000 ps2=16777215 ps3=200 ps4=2000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 58824 [+]: 28987 [-]: 28987
TIME : [0]: 19.147 mins [+]: 9.469 mins [-]: 9.469 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.59112 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: -2.15% [+]: -1.90% [-]: -1.48%
TRIGGER RATES: PRES/REAL
T1[0] : 5.7/22992.1 Hz T2[0] : 0.0/0.0 Hz T3[0] :10.6/2112.2 Hz T4[0] : 7.5/15061.9 Hz T5[0] :16.1/16.1 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 5.7/22968.5 Hz T2[+] : 0.0/0.0 Hz T3[+] :10.5/2108.8 Hz T4[+] : 7.5/15044.5 Hz T5[+] :16.1/16.1 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 5.8/23064.7 Hz T2[-] : 0.0/0.0 Hz T3[-] :10.6/2119.9 Hz T4[-] : 7.6/15103.5 Hz T5[-] :16.2/16.2 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 6603/26414178 T2[0] : 0/0 T3[0] : 12132/2426575 T4[0] : 8651/17303602 T5[0] : 18537/18537 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 11764/1176408
T1[+] : 3262/13048682 T2[+] : 0/0 T3[+] : 5990/1198038 T4[+] : 4273/8546975 T5[+] : 9156/9156 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 5817/581748
T1[-] : 3275/13103836 T2[-] : 0/0 T3[-] : 6021/1204371 T4[-] : 4290/8580830 T5[-] : 9212/9212 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 5817/581769
AVERAGE CURRENT
BCM x1 : 16.7621uA BCM x3 : 16.7620uA BCM x10: 8.4105 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1944 ppm BCM u3 : -1887 ppm BCM u10: 1E+39 ppm
BCM d1 : -1949 ppm BCM d3 : -1859 ppm BCM d10: -1875 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01933 BCM u3 [0]:0.01933 BCM u10[0]:-2.138E-05
BCM u1 [+]:0.009549 BCM u3 [+]:0.00955 BCM u10[+]:-1.057E-05
BCM u1 [-]:0.009586 BCM u3 [-]:0.009587 BCM u10[-]:-1.057E-05
BCM d1 [0]:0.01919 BCM d3 [0]:0.01918 BCM d10[0]:0.01935
BCM d1 [+]:0.00948 BCM d3 [+]:0.009479 BCM d10[+]:0.009559
BCM d1 [-]:0.009517 BCM d3 [-]:0.009515 BCM d10[-]:0.009595
****************************
End-of-run EPICS data for Run Number 1768 at Sat May 31 19:48:09 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.93133
Left Arm arm angle : 43.4997
Right Arm D1 momentum : 0.00436705
Right Arm arm angle : 0.197
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 0.78125
Left Arm Bottom VDC Current : 1.95312
-----
Left Arm Q1 momentum : 0.931435
Left Arm Q1 power supply : 700.694
Left Arm Q1 gauss meter : 0.0598
Left Arm Q2 gauss meter : -0.2111
Left Arm Q2 power supply current : 401.051
Left Arm Q2 momentum : 0.931378
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 310.712
Left Arm D1 momentum : 0.93133
Left Arm D1 NMR : 0.392308
Left Arm Q3 gauss meter : 0.188597
Left Arm Q3 power supply current : 370.699
Left Arm Q3 momentum : 0.931125
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00566808
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001269
Right Arm Q2 power supply current : -0.000214449
Right Arm Q2 momentum : -1.71825e-07
Right Arm Q2 gauss meter : -0.0002904
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0268464
Right Arm D1 momentum : 0.00435587
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -5.60446e-05
Right Arm Q3 momentum : -1.97187e-07
Right Arm Q3 gauss meter : -0.0002663
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.5637
-----
Average current of the two cavities : 0.0251386
Current on Unser monitor : 12.9257
Current on Upstream bcm : 0.0349472
Current on Downstream bcm : 0.0153299
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00929746
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5711.11
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.247559
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.252441
-----
Right Arm Collimator : -0.00820313
HacR_HPE1313A:0_Ch58 : -0.569336
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.84668
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 75
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.83354
SLI vert. size mm : 0
SLI y position : 2.37371
-----
Target : Dummy
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 1.32517e+07
Target type : 1.32517e+07
temperature loop 1(1) : 101.19
temperature loop 1(2) : 100.81
temperature loop 1(3) : 95.77
temperature loop 3(1) : 20
temperature loop 3(2) : 19.98
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.3
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0813417
HPH H2 loop 3 : 90.2899
-----