    keyword=End_of_Run_1770
    ****************************
     Run Number: 1770
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine 8, Delta=-2
     
    
    PRESCALE FACTORS:ps1=4000   ps2=16777215   ps3=200   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5005478      [+]: 2462365      [-]: 2468863      
    TIME     : [0]: 61.135 mins  [+]: 30.150 mins  [-]: 30.147 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.60308 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  27.28%      [+]:  27.34%      [-]:  27.42%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.5/69905.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :17.9/3581.8 Hz   T4[0] : 8.2/16497.2 Hz   T5[0] :1832.6/1832.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.4/69780.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :17.9/3574.6 Hz   T4[+] : 8.2/16476.2 Hz   T5[+] :1829.3/1829.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.5/70057.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :17.9/3589.7 Hz   T4[-] : 8.3/16523.5 Hz   T5[-] :1836.3/1836.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  64105/256421185  T2[0] :      0/0        T3[0] :  65691/13138262  T4[0] :  30256/60513646  T5[0] :6722062/6722062  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  37561/3756147  
    T1[+] :  31557/126231738  T2[+] :      0/0        T3[+] :  32332/6466469  T4[+] :  14902/29805238  T5[+] :3309119/3309119  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  18524/1852403  
    T1[-] :  31680/126723000  T2[-] :      0/0        T3[-] :  32465/6493157  T4[-] :  14944/29888374  T5[-] :3321517/3321517  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  18522/1852255  
    
    AVERAGE CURRENT
    BCM x1 : 17.8722uA  BCM x3 : 17.8711uA  BCM x10: 8.9658 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -2073 ppm     BCM u3 :    -2017 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -2079 ppm     BCM d3 :    -1990 ppm     BCM d10:    -2003 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0658         BCM u3 [0]:0.06581        BCM u10[0]:-6.822E-05     
    BCM u1 [+]:0.03239        BCM u3 [+]:0.0324         BCM u10[+]:-3.364E-05     
    BCM u1 [-]:0.03252        BCM u3 [-]:0.03253        BCM u10[-]:-3.364E-05     
    
    BCM d1 [0]:0.06531        BCM d3 [0]:0.06529        BCM d10[0]:0.06584        
    BCM d1 [+]:0.03215        BCM d3 [+]:0.03214        BCM d10[+]:0.03241        
    BCM d1 [-]:0.03228        BCM d3 [-]:0.03227        BCM d10[-]:0.03254        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1770 at Sat May 31 21:57:49 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.931328
    Left Arm arm angle : 43.4997
    Right Arm D1 momentum : 0.00436214
    Right Arm arm angle : 0.197
    HALLA:p : 1192.12
    HALLA:dpp : -0.000219579
    Tiefenbach Hall A energy : 1192.12
    Left Arm Top VDC Current : 4.88281
    Left Arm Bottom VDC Current : 3.32031
    -----
    Left Arm Q1 momentum : 0.931364
    Left Arm Q1 power supply : 700.748
    Left Arm Q1 gauss meter : 0.05981
    Left Arm Q2 gauss meter : -0.2111
    Left Arm Q2 power supply current : 401.051
    Left Arm Q2 momentum : 0.931377
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 310.713
    Left Arm D1 momentum : 0.931328
    Left Arm D1 NMR : 0.392307
    Left Arm Q3 gauss meter : 0.188602
    Left Arm Q3 power supply current : 370.697
    Left Arm Q3 momentum : 0.931122
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00441676
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.000113
    Right Arm Q2 power supply current : -4.43687e-05
    Right Arm Q2 momentum : -1.11686e-07
    Right Arm Q2 gauss meter : -0.0002975
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0254767
    Right Arm D1 momentum : 0.00436214
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 7.09898e-05
    Right Arm Q3 momentum : -2.91085e-07
    Right Arm Q3 gauss meter : -0.0002664
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 21.2914
    Current on Unser monitor : 32.1057
    Current on Upstream bcm : 21.0332
    Current on Downstream bcm : 21.6339
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 95.9504
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.12
    Hall A momentum orbit correction (dpp) : -0.000219038
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.12
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.21834
    IPM1C12.XPOS : 0.904135
    IPM1H04A.XPOS : -1.13154
    IPM1H04A.YPOS : 1.16049
    IPM1H04B.XPOS : -1.79983
    IPM1H04B.YPOS : 1.93634
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.248535
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.251953
    -----
    Right Arm Collimator : -0.00864258
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.846191
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 195
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.29689
    SLI vert. size mm : 0
    SLI y position : 0.435681
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 101.17
    temperature loop 1(2) : 100.79
    temperature loop 1(3) : 95.82
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.3
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0322691
    HPH H2 loop 3 : 61.502
    -----