Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:57:38 on June 9, 2008

    Entry number 241654

    keyword=End_of_Run_2058
    ****************************
     Run Number: 2058
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 production
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=350   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5007912      [+]: 2467692      [-]: 2466200      
    TIME     : [0]: 40.181 mins  [+]: 19.828 mins  [-]: 19.829 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.69753 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  39.88%      [+]:  40.00%      [-]:  40.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.8/33595.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :15.9/5578.0 Hz   T4[0] : 4.4/13124.6 Hz   T5[0] :3419.6/3419.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :16.8/33603.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :15.9/5580.5 Hz   T4[+] : 4.4/13133.3 Hz   T5[+] :3421.6/3421.6 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :16.8/33602.3 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :15.9/5577.7 Hz   T4[-] : 4.4/13121.6 Hz   T5[-] :3419.3/3419.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  40496/80993474  T2[0] :      0/0        T3[0] :  38422/13447808  T4[0] :  10547/31641380  T5[0] :8244030/8244030  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24687/2468705  
    T1[+] :  19988/39977970  T2[+] :      0/0        T3[+] :  18968/6639124  T4[+] :   5208/15624748  T5[+] :4070706/4070706  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12182/1218260  
    T1[-] :  19989/39978839  T2[-] :      0/0        T3[-] :  18960/6636178  T4[-] :   5203/15611580  T5[-] :4068121/4068121  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12183/1218318  
    
    AVERAGE CURRENT
    BCM x1 : 2.2115 uA  BCM x3 : 2.2150 uA  BCM x10: 1.1066 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -187.1 ppm     BCM u3 :   -67.71 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -223.1 ppm     BCM d3 :   -76.88 ppm     BCM d10:   -29.03 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005346       BCM u3 [0]:0.00535        BCM u10[0]:-4.492E-05     
    BCM u1 [+]:0.002638       BCM u3 [+]:0.002641       BCM u10[+]:-2.217E-05     
    BCM u1 [-]:0.002639       BCM u3 [-]:0.002641       BCM u10[-]:-2.217E-05     
    
    BCM d1 [0]:0.005318       BCM d3 [0]:0.00533        BCM d10[0]:0.005381       
    BCM d1 [+]:0.002624       BCM d3 [+]:0.002631       BCM d10[+]:0.002656       
    BCM d1 [-]:0.002625       BCM d3 [-]:0.002631       BCM d10[-]:0.002656       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2058 at Mon Jun 9 01:57:28 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.616191
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00436323
    Right Arm arm angle : 0.197
    HALLA:p : 1192.22
    HALLA:dpp : -0.000136621
    Tiefenbach Hall A energy : 1192.22
    Left Arm Top VDC Current : 4.15039
    Left Arm Bottom VDC Current : -1.80664
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.622
    Left Arm Q1 gauss meter : 0.03988
    Left Arm Q2 gauss meter : -0.13998
    Left Arm Q2 power supply current : 265.27
    Left Arm Q2 momentum : 0.616047
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.374
    Left Arm D1 momentum : 0.616191
    Left Arm D1 NMR : 0.259476
    Left Arm Q3 gauss meter : 0.125418
    Left Arm Q3 power supply current : 245.287
    Left Arm Q3 momentum : 0.616116
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00220042
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.15e-05
    Right Arm Q2 power supply current : -0.000133106
    Right Arm Q2 momentum : -3.09285e-07
    Right Arm Q2 gauss meter : -0.0002992
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0272206
    Right Arm D1 momentum : 0.00436814
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000257805
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 2.51717
    Current on Unser monitor : 13.4355
    Current on Upstream bcm : 2.50353
    Current on Downstream bcm : 2.53082
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 84.937
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.2
    Hall A momentum orbit correction (dpp) : -0.000151991
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.22
    Hall C energy (hallc_MeV) : 5711
    Delta(E)/E width (MV_AI_DXWID) : 1.18813
    IPM1C12.XPOS : 0.56017
    IPM1H04A.XPOS : -1.15218
    IPM1H04A.YPOS : 1.22681
    IPM1H04B.XPOS : -1.81217
    IPM1H04B.YPOS : 1.89003
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.298828
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.314941
    -----
    Right Arm Collimator : -0.00825195
    HacR_HPE1313A:0_Ch58 : -0.56543
    HacR_HPE1313A:0_Ch55 : 22.4609
    HacR_HPE1313A:0_Ch54 : -0.842285
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.00621
    SLI vert. size mm : 0
    SLI y position : 0.458216
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 12
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.42
    temperature loop 1(2) : 105.06
    temperature loop 1(3) : 99.95
    temperature loop 3(1) : 19.47
    temperature loop 3(2) : 19.45
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.8
    Heat exchange LH2 : 19.8
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.0170928
    -----