Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:36:45 on June 9, 2008

    Entry number 241658

    keyword=End_of_Run_2059
    ****************************
     Run Number: 2059
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 production
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=350   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5000955      [+]: 2462212      [-]: 2464695      
    TIME     : [0]: 38.464 mins  [+]: 18.994 mins  [-]: 18.992 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.73160 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  40.08%      [+]:  40.21%      [-]:  40.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.6/35185.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.7/5839.7 Hz   T4[0] : 4.6/13688.0 Hz   T5[0] :3579.7/3579.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.6/35178.8 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.7/5835.5 Hz   T4[+] : 4.6/13679.9 Hz   T5[+] :3577.1/3577.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.6/35204.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.7/5845.7 Hz   T4[-] : 4.6/13700.7 Hz   T5[-] :3583.3/3583.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  40601/81203786  T2[0] :      0/0        T3[0] :  38506/13477137  T4[0] :  10530/31590073  T5[0] :8261467/8261467  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  23632/2363248  
    T1[+] :  20045/40090847  T2[+] :      0/0        T3[+] :  19001/6650361  T4[+] :   5196/15590025  T5[+] :4076593/4076593  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11669/1166983  
    T1[-] :  20057/40115796  T2[-] :      0/0        T3[-] :  19031/6661152  T4[-] :   5203/15611799  T5[-] :4083189/4083189  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11668/1166841  
    
    AVERAGE CURRENT
    BCM x1 : 2.3282 uA  BCM x3 : 2.3317 uA  BCM x10: 1.1650 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -286.2 ppm     BCM u3 :   -166.6 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -322.2 ppm     BCM d3 :   -164.6 ppm     BCM d10:   -124.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005389       BCM u3 [0]:0.005393       BCM u10[0]:-4.299E-05     
    BCM u1 [+]:0.002661       BCM u3 [+]:0.002663       BCM u10[+]:-2.123E-05     
    BCM u1 [-]:0.002662       BCM u3 [-]:0.002664       BCM u10[-]:-2.123E-05     
    
    BCM d1 [0]:0.005357       BCM d3 [0]:0.005369       BCM d10[0]:0.00542        
    BCM d1 [+]:0.002645       BCM d3 [+]:0.002651       BCM d10[+]:0.002677       
    BCM d1 [-]:0.002647       BCM d3 [-]:0.002652       BCM d10[-]:0.002677       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2059 at Mon Jun 9 02:36:35 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.616191
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00435315
    Right Arm arm angle : 0.197
    HALLA:p : 1192.23
    HALLA:dpp : -0.000124939
    Tiefenbach Hall A energy : 1192.24
    Left Arm Top VDC Current : 4.15039
    Left Arm Bottom VDC Current : -2.05078
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.569
    Left Arm Q1 gauss meter : 0.03988
    Left Arm Q2 gauss meter : -0.14002
    Left Arm Q2 power supply current : 265.27
    Left Arm Q2 momentum : 0.616047
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.377
    Left Arm D1 momentum : 0.616191
    Left Arm D1 NMR : 0.259476
    Left Arm Q3 gauss meter : 0.125427
    Left Arm Q3 power supply current : 245.287
    Left Arm Q3 momentum : 0.616116
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00321315
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.12e-05
    Right Arm Q2 power supply current : -0.000292094
    Right Arm Q2 momentum : -6.78709e-07
    Right Arm Q2 gauss meter : -0.0002926
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0305741
    Right Arm D1 momentum : 0.00435478
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -3.7363e-06
    Right Arm Q3 momentum : -9.38985e-09
    Right Arm Q3 gauss meter : -0.0002701
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 2.5136
    Current on Unser monitor : 13.6466
    Current on Upstream bcm : 2.47877
    Current on Downstream bcm : 2.54842
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.6848
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.21
    Hall A momentum orbit correction (dpp) : -0.000147543
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.21
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.17507
    IPM1C12.XPOS : 0.593682
    IPM1H04A.XPOS : -1.14199
    IPM1H04A.YPOS : 1.23065
    IPM1H04B.XPOS : -1.8016
    IPM1H04B.YPOS : 1.91276
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.298828
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.314941
    -----
    Right Arm Collimator : -0.00888672
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.4121
    HacR_HPE1313A:0_Ch54 : -0.842285
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.56646
    SLI vert. size mm : 0
    SLI y position : 3.00469
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5.5
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.41
    temperature loop 1(2) : 105.06
    temperature loop 1(3) : 99.78
    temperature loop 3(1) : 19.39
    temperature loop 3(2) : 19.37
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.8
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068
    -----