    keyword=End_of_Run_2061
    ****************************
     Run Number: 2061
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 production
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=350   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5007842      [+]: 2465807      [-]: 2467562      
    TIME     : [0]: 44.977 mins  [+]: 22.198 mins  [-]: 22.202 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.98668 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  39.81%      [+]:  39.94%      [-]:  39.96%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.0/29920.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :14.2/4984.0 Hz   T4[0] : 3.9/11846.3 Hz   T5[0] :3050.3/3050.3 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :15.0/29930.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :14.2/4983.2 Hz   T4[+] : 3.9/11849.4 Hz   T5[+] :3049.9/3049.9 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :15.0/29934.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :14.3/4988.0 Hz   T4[-] : 4.0/11850.8 Hz   T5[-] :3052.6/3052.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  40371/80743000  T2[0] :      0/0        T3[0] :  38428/13449907  T4[0] :  10656/31968579  T5[0] :8231479/8231479  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  27633/2763371  
    T1[+] :  19931/39863790  T2[+] :      0/0        T3[+] :  18962/6637008  T4[+] :   5260/15781894  T5[+] :4062060/4062060  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  13638/1363838  
    T1[-] :  19937/39875073  T2[-] :      0/0        T3[-] :  18984/6644439  T4[-] :   5262/15786447  T5[-] :4066399/4066399  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  13640/1364065  
    
    AVERAGE CURRENT
    BCM x1 : 1.9885 uA  BCM x3 : 1.9918 uA  BCM x10: 0.9938 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -194.8 ppm     BCM u3 :   -56.31 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -232.3 ppm     BCM d3 :   -54.27 ppm     BCM d10:   -7.299 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005382       BCM u3 [0]:0.005387       BCM u10[0]:-5.024E-05     
    BCM u1 [+]:0.002657       BCM u3 [+]:0.00266        BCM u10[+]:-2.48E-05      
    BCM u1 [-]:0.002658       BCM u3 [-]:0.00266        BCM u10[-]:-2.48E-05      
    
    BCM d1 [0]:0.00535        BCM d3 [0]:0.005363       BCM d10[0]:0.005414       
    BCM d1 [+]:0.002641       BCM d3 [+]:0.002648       BCM d10[+]:0.002673       
    BCM d1 [-]:0.002643       BCM d3 [-]:0.002649       BCM d10[-]:0.002674       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2061 at Mon Jun 9 04:04:14 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.616191
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00438258
    Right Arm arm angle : 0.197
    HALLA:p : 1192.2
    HALLA:dpp : -0.000152341
    Tiefenbach Hall A energy : 1192.2
    Left Arm Top VDC Current : 4.63867
    Left Arm Bottom VDC Current : -2.19727
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.569
    Left Arm Q1 gauss meter : 0.03988
    Left Arm Q2 gauss meter : -0.14006
    Left Arm Q2 power supply current : 265.27
    Left Arm Q2 momentum : 0.616047
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.379
    Left Arm D1 momentum : 0.616191
    Left Arm D1 NMR : 0.259476
    Left Arm Q3 gauss meter : 0.125402
    Left Arm Q3 power supply current : 245.287
    Left Arm Q3 momentum : 0.616115
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00187169
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.32e-05
    Right Arm Q2 power supply current : -0.000107224
    Right Arm Q2 momentum : -2.49146e-07
    Right Arm Q2 gauss meter : -0.0002958
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.026331
    Right Arm D1 momentum : 0.00438612
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -5.60446e-05
    Right Arm Q3 momentum : -1.40848e-07
    Right Arm Q3 gauss meter : -0.0002701
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.44712
    Current on Unser monitor : 13.6167
    Current on Upstream bcm : 2.4008
    Current on Downstream bcm : 2.49344
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.5501
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.21
    Hall A momentum orbit correction (dpp) : -0.000142646
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.21
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.17865
    IPM1C12.XPOS : 0.554173
    IPM1H04A.XPOS : -1.14679
    IPM1H04A.YPOS : 1.22882
    IPM1H04B.XPOS : -1.79606
    IPM1H04B.YPOS : 1.87906
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.297852
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.314941
    -----
    Right Arm Collimator : -0.00839844
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.4121
    HacR_HPE1313A:0_Ch54 : -0.841797
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.43106
    SLI vert. size mm : 0
    SLI y position : 0.443193
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 7.5
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.37
    temperature loop 1(2) : 105.02
    temperature loop 1(3) : 99.52
    temperature loop 3(1) : 19.79
    temperature loop 3(2) : 19.77
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.8
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00293052
    -----