Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:03:30 on June 9, 2008

    Entry number 241676

    keyword=End_of_Run_2065
    ****************************
     Run Number: 2065
     End of Run Comment:
    Run_type=Production,target_type=Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 Carbon
     
    
    PRESCALE FACTORS:ps1=160   ps2=16777215   ps3=1   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 600756       [+]: 296086       [-]: 295892       
    TIME     : [0]: 3.979 mins  [+]: 2.005 mins  [-]: 2.006 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.80836 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  74.07%      [+]:  74.18%      [-]:  74.15%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :49.1/7856.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1747.7/1747.7 Hz   T4[0] :9644.2/9644.2 Hz   T5[0] :22.0/22.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :47.9/7669.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1709.9/1709.9 Hz   T4[+] :9474.7/9474.7 Hz   T5[+] :21.5/21.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :48.0/7687.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1708.2/1708.2 Hz   T4[-] :9451.0/9451.0 Hz   T5[-] :22.2/22.2 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  11723/1875771  T2[0] :      0/0        T3[0] : 417260/417260   T4[0] :2302573/2302573  T5[0] :   5255/5255     T6[0] :      0/0        T7[0] :      0/0        T8[0] :   2444/244481   
    T1[+] :   5768/922895   T2[+] :      0/0        T3[+] : 205746/205746   T4[+] :1140058/1140058  T5[+] :   2581/2581     T6[+] :      0/0        T7[+] :      0/0        T8[+] :   1232/123214   
    T1[-] :   5783/925388   T2[-] :      0/0        T3[-] : 205639/205639   T4[-] :1137731/1137731  T5[-] :   2670/2670     T6[-] :      0/0        T7[-] :      0/0        T8[-] :   1232/123271   
    
    AVERAGE CURRENT
    BCM x1 : 10.3764uA  BCM x3 : 10.3782uA  BCM x10: 5.2078 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    220.6 ppm     BCM u3 :      246 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :      211 ppm     BCM d3 :    243.9 ppm     BCM d10:    255.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002484       BCM u3 [0]:0.002485       BCM u10[0]:-4.447E-06     
    BCM u1 [+]:0.001224       BCM u3 [+]:0.001224       BCM u10[+]:-2.242E-06     
    BCM u1 [-]:0.001224       BCM u3 [-]:0.001224       BCM u10[-]:-2.242E-06     
    
    BCM d1 [0]:0.002471       BCM d3 [0]:0.002471       BCM d10[0]:0.002491       
    BCM d1 [+]:0.001217       BCM d3 [+]:0.001217       BCM d10[+]:0.001227       
    BCM d1 [-]:0.001217       BCM d3 [-]:0.001217       BCM d10[-]:0.001227       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2065 at Mon Jun 9 06:03:20 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.61619
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00432617
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -1.95312
    Left Arm Bottom VDC Current : 3.17383
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.569
    Left Arm Q1 gauss meter : 0.03989
    Left Arm Q2 gauss meter : -0.14006
    Left Arm Q2 power supply current : 265.271
    Left Arm Q2 momentum : 0.61605
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.377
    Left Arm D1 momentum : 0.61619
    Left Arm D1 NMR : 0.259476
    Left Arm Q3 gauss meter : 0.125413
    Left Arm Q3 power supply current : 245.289
    Left Arm Q3 momentum : 0.616119
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00408802
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.8e-05
    Right Arm Q2 power supply current : -0.000155291
    Right Arm Q2 momentum : -3.17876e-07
    Right Arm Q2 gauss meter : -0.0002929
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0274853
    Right Arm D1 momentum : 0.00433216
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -1.49452e-05
    Right Arm Q3 momentum : -9.38985e-09
    Right Arm Q3 gauss meter : -0.0002702
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11255
    -----
    Average current of the two cavities : 0.0249152
    Current on Unser monitor : 12.0904
    Current on Upstream bcm : 0.0346483
    Current on Downstream bcm : 0.015182
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00582726
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.29834
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.315918
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.4609
    HacR_HPE1313A:0_Ch54 : -0.84082
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.0882
    SLI vert. size mm : 0
    SLI y position : 0.488263
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5.5
    Encoder position : 9.10321e+06
    Target type : 9.10321e+06
    temperature loop 1(1) : 105.58
    temperature loop 1(2) : 105.22
    temperature loop 1(3) : 99.78
    temperature loop 3(1) : 19.83
    temperature loop 3(2) : 19.8
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00293052
    -----