Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:06:18 on June 9, 2008

    Entry number 241678

    keyword=End_of_Run_2066
    ****************************
     Run Number: 2066
     End of Run Comment:
    Run_type=Production,target_type=Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 Carbon
     
    
    PRESCALE FACTORS:ps1=160   ps2=16777215   ps3=3   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 252243       [+]: 123779       [-]: 124708       
    TIME     : [0]: 1.143 mins  [+]: 0.597 mins  [-]: 0.597 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.26028 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  79.08%      [+]:  80.36%      [-]:  80.20%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.9/15663.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1133.1/3399.3 Hz   T4[0] :17454.2/17454.2 Hz   T5[0] :31.9/31.9 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :97.7/15633.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1134.2/3402.8 Hz   T4[+] :17453.9/17453.9 Hz   T5[+] :31.2/31.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :98.0/15682.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1134.6/3403.8 Hz   T4[-] :17444.8/17444.8 Hz   T5[-] :32.3/32.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   6713/1074117  T2[0] :      0/0        T3[0] :  77702/233107   T4[0] :1196907/1196907  T5[0] :   2189/2189     T6[0] :      0/0        T7[0] :      0/0        T8[0] :    702/70220    
    T1[+] :   3502/560440   T2[+] :      0/0        T3[+] :  40662/121988   T4[+] : 625715/625715   T5[+] :   1117/1117     T6[+] :      0/0        T7[+] :      0/0        T8[+] :    367/36710    
    T1[-] :   3512/562043   T2[-] :      0/0        T3[-] :  40661/121984   T4[-] : 625186/625186   T5[-] :   1157/1157     T6[-] :      0/0        T7[-] :      0/0        T8[-] :    366/36698    
    
    AVERAGE CURRENT
    BCM x1 : 20.6033uA  BCM x3 : 20.6041uA  BCM x10: 10.3465uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    72.41 ppm     BCM u3 :    91.55 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    74.53 ppm     BCM d3 :    98.72 ppm     BCM d10:    99.44 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001417       BCM u3 [0]:0.001417       BCM u10[0]:-1.277E-06     
    BCM u1 [+]:0.0007407      BCM u3 [+]:0.0007409      BCM u10[+]:-6.678E-07     
    BCM u1 [-]:0.0007403      BCM u3 [-]:0.0007406      BCM u10[-]:-6.668E-07     
    
    BCM d1 [0]:0.001409       BCM d3 [0]:0.001409       BCM d10[0]:0.00142        
    BCM d1 [+]:0.0007367      BCM d3 [+]:0.0007365      BCM d10[+]:0.0007426      
    BCM d1 [-]:0.0007363      BCM d3 [-]:0.0007361      BCM d10[-]:0.0007422      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2066 at Mon Jun 9 06:06:08 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.61619
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00435723
    Right Arm arm angle : 0.197
    HALLA:p : 1192.23
    HALLA:dpp : -0.000132617
    Tiefenbach Hall A energy : 1192.23
    Left Arm Top VDC Current : 2.83203
    Left Arm Bottom VDC Current : -1.95312
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.569
    Left Arm Q1 gauss meter : 0.03989
    Left Arm Q2 gauss meter : -0.14006
    Left Arm Q2 power supply current : 265.272
    Left Arm Q2 momentum : 0.616051
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.376
    Left Arm D1 momentum : 0.61619
    Left Arm D1 NMR : 0.259476
    Left Arm Q3 gauss meter : 0.125416
    Left Arm Q3 power supply current : 245.289
    Left Arm Q3 momentum : 0.616119
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00296925
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.41e-05
    Right Arm Q2 power supply current : -0.000173778
    Right Arm Q2 momentum : -2.57738e-07
    Right Arm Q2 gauss meter : -0.0002944
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0261333
    Right Arm D1 momentum : 0.00435723
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000134507
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002701
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 20.5804
    Current on Unser monitor : 31.6523
    Current on Upstream bcm : 20.3406
    Current on Downstream bcm : 20.8202
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 101.835
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.22
    Hall A momentum orbit correction (dpp) : -0.000134612
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.22
    Hall C energy (hallc_MeV) : 5710.97
    Delta(E)/E width (MV_AI_DXWID) : 1.17833
    IPM1C12.XPOS : 0.525809
    IPM1H04A.XPOS : -1.14994
    IPM1H04A.YPOS : 1.19714
    IPM1H04B.XPOS : -1.78916
    IPM1H04B.YPOS : 1.86221
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.297852
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.315918
    -----
    Right Arm Collimator : -0.00839844
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.5098
    HacR_HPE1313A:0_Ch54 : -0.841309
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 149
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.10932
    SLI vert. size mm : 0
    SLI y position : 1.9831
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 6.5
    Encoder position : 9.10321e+06
    Target type : 9.10321e+06
    temperature loop 1(1) : 105.62
    temperature loop 1(2) : 105.26
    temperature loop 1(3) : 99.7
    temperature loop 3(1) : 19.7
    temperature loop 3(2) : 19.68
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.011068
    -----