Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:16:16 on June 9, 2008

    Entry number 241683

    keyword=End_of_Run_2068
    ****************************
     Run Number: 2068
     End of Run Comment:
    Run_type=Production,target_type=Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6162,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1D0 Carbon Raster On
     
    
    PRESCALE FACTORS:ps1=160   ps2=16777215   ps3=3   ps4=170   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 255247       [+]: 125829       [-]: 125658       
    TIME     : [0]: 4.129 mins  [+]: 2.069 mins  [-]: 2.070 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.53358 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  13.74%      [+]:  15.35%      [-]:  15.41%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :85.6/13692.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :994.5/2983.4 Hz   T4[0] :90.7/15419.0 Hz   T5[0] :29.0/29.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :85.8/13727.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :997.4/2992.2 Hz   T4[+] :91.0/15463.5 Hz   T5[+] :29.1/29.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :85.7/13715.2 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :996.0/2988.1 Hz   T4[-] :90.8/15432.0 Hz   T5[-] :29.1/29.1 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  21202/3392409  T2[0] :      0/0        T3[0] : 246384/739153   T4[0] :  22471/3820107  T5[0] :   7195/7195     T6[0] :      0/0        T7[0] :      0/0        T8[0] :   2537/253700   
    T1[+] :  10648/1703770  T2[+] :      0/0        T3[+] : 123792/371378   T4[+] :  11289/1919246  T5[+] :   3612/3612     T6[+] :      0/0        T7[+] :      0/0        T8[+] :   1270/127093   
    T1[-] :  10646/1703430  T2[-] :      0/0        T3[-] : 123707/371121   T4[-] :  11274/1916655  T5[-] :   3615/3615     T6[-] :      0/0        T7[-] :      0/0        T8[-] :   1271/127181   
    
    AVERAGE CURRENT
    BCM x1 : 18.0145uA  BCM x3 : 18.0155uA  BCM x10: 9.0463 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -25.75 ppm     BCM u3 :   -14.06 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -39.2 ppm     BCM d3 :    -12.8 ppm     BCM d10:   -9.779 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.004475       BCM u3 [0]:0.004476       BCM u10[0]:-4.611E-06     
    BCM u1 [+]:0.002246       BCM u3 [+]:0.002247       BCM u10[+]:-2.31E-06      
    BCM u1 [-]:0.002248       BCM u3 [-]:0.002249       BCM u10[-]:-2.312E-06     
    
    BCM d1 [0]:0.004452       BCM d3 [0]:0.004451       BCM d10[0]:0.004487       
    BCM d1 [+]:0.002235       BCM d3 [+]:0.002235       BCM d10[+]:0.002253       
    BCM d1 [-]:0.002237       BCM d3 [-]:0.002236       BCM d10[-]:0.002254       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2068 at Mon Jun 9 06:16:06 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.616196
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.0043477
    Right Arm arm angle : 0.197
    HALLA:p : 1192.22
    HALLA:dpp : -0.000136364
    Tiefenbach Hall A energy : 1192.22
    Left Arm Top VDC Current : -1.12305
    Left Arm Bottom VDC Current : 3.32031
    -----
    Left Arm Q1 momentum : 0.616177
    Left Arm Q1 power supply : 463.569
    Left Arm Q1 gauss meter : 0.03989
    Left Arm Q2 gauss meter : -0.14007
    Left Arm Q2 power supply current : 265.272
    Left Arm Q2 momentum : 0.616053
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 204.376
    Left Arm D1 momentum : 0.616196
    Left Arm D1 NMR : 0.259478
    Left Arm Q3 gauss meter : 0.125403
    Left Arm Q3 power supply current : 245.289
    Left Arm Q3 momentum : 0.61612
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00279958
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -7.28e-05
    Right Arm Q2 power supply current : -9.98296e-05
    Right Arm Q2 momentum : 0.00120216
    Right Arm Q2 gauss meter : -0.000292
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0257167
    Right Arm D1 momentum : 0.00436078
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 1.86815e-05
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 20.7844
    Current on Unser monitor : 31.6044
    Current on Upstream bcm : 20.4628
    Current on Downstream bcm : 21.106
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 101.519
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.22
    Hall A momentum orbit correction (dpp) : -0.0001357
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.23
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.17956
    IPM1C12.XPOS : 0.53342
    IPM1H04A.XPOS : -1.16158
    IPM1H04A.YPOS : 1.24885
    IPM1H04B.XPOS : -1.80832
    IPM1H04B.YPOS : 1.91488
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.29834
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.315918
    -----
    Right Arm Collimator : -0.00839844
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.4609
    HacR_HPE1313A:0_Ch54 : -0.841309
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 150
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.16894
    SLI vert. size mm : 0
    SLI y position : 1.32207
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 2
    Encoder position : 9.10321e+06
    Target type : 9.10321e+06
    temperature loop 1(1) : 105.73
    temperature loop 1(2) : 105.37
    temperature loop 1(3) : 99.63
    temperature loop 3(1) : 19.4
    temperature loop 3(2) : 19.38
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.6
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00634721
    -----