     Run Number: 2073
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6039,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1 delta=2 production
     
    
    PRESCALE FACTORS:ps1=1500   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5008449      [+]: 2467113      [-]: 2467364      
    TIME     : [0]: 39.398 mins  [+]: 19.443 mins  [-]: 19.444 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.72745 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  38.85%      [+]:  38.97%      [-]:  38.97%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :22.0/32992.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :20.8/6231.8 Hz   T4[0] : 4.9/14716.9 Hz   T5[0] :3420.9/3420.9 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :22.0/32991.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :20.8/6231.9 Hz   T4[+] : 4.9/14718.0 Hz   T5[+] :3421.5/3421.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :22.0/32998.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :20.8/6233.5 Hz   T4[-] : 4.9/14718.9 Hz   T5[-] :3421.3/3421.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  51993/77989806  T2[0] :      0/0        T3[0] :  49103/14731046  T4[0] :  11596/34788618  T5[0] :8086406/8086406  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24205/2420584  
    T1[+] :  25658/38487297  T2[+] :      0/0        T3[+] :  24233/7270178  T4[+] :   5723/17170017  T5[+] :3991523/3991523  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11945/1194596  
    T1[-] :  25665/38497574  T2[-] :      0/0        T3[-] :  24240/7272251  T4[-] :   5723/17171838  T5[-] :3991416/3991416  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11946/1194649  
    
    AVERAGE CURRENT
    BCM x1 : 2.3557 uA  BCM x3 : 2.3593 uA  BCM x10: 1.1790 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -248.8 ppm     BCM u3 :   -125.5 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :     -287 ppm     BCM d3 :   -119.2 ppm     BCM d10:    -87.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005585       BCM u3 [0]:0.005589       BCM u10[0]:-4.402E-05     
    BCM u1 [+]:0.002756       BCM u3 [+]:0.002758       BCM u10[+]:-2.172E-05     
    BCM u1 [-]:0.002757       BCM u3 [-]:0.002759       BCM u10[-]:-2.172E-05     
    
    BCM d1 [0]:0.005552       BCM d3 [0]:0.005565       BCM d10[0]:0.005618       
    BCM d1 [+]:0.00274        BCM d3 [+]:0.002746       BCM d10[+]:0.002773       
    BCM d1 [-]:0.002741       BCM d3 [-]:0.002747       BCM d10[-]:0.002773       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2073 at Mon Jun 9 09:29:24 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.603886
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00434879
    Right Arm arm angle : 0.197
    HALLA:p : 1192.19
    HALLA:dpp : -0.000164358
    Tiefenbach Hall A energy : 1192.19
    Left Arm Top VDC Current : 2.92969
    Left Arm Bottom VDC Current : 0.341797
    -----
    Left Arm Q1 momentum : 0.603896
    Left Arm Q1 power supply : 454.33
    Left Arm Q1 gauss meter : 0.0391
    Left Arm Q2 gauss meter : -0.13725
    Left Arm Q2 power supply current : 260.015
    Left Arm Q2 momentum : 0.603843
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 200.137
    Left Arm D1 momentum : 0.603886
    Left Arm D1 NMR : 0.254289
    Left Arm Q3 gauss meter : 0.122945
    Left Arm Q3 power supply current : 240.402
    Left Arm Q3 momentum : 0.603847
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00269883
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -7.09e-05
    Right Arm Q2 power supply current : -0.000103527
    Right Arm Q2 momentum : -1.71825e-07
    Right Arm Q2 gauss meter : -0.0002894
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0265004
    Right Arm D1 momentum : 0.00434088
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 7.84624e-05
    Right Arm Q3 momentum : -2.06577e-07
    Right Arm Q3 gauss meter : -0.0002702
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.45818
    Current on Unser monitor : 15.3021
    Current on Upstream bcm : 2.42238
    Current on Downstream bcm : 2.49399
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 85.1818
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.19
    Hall A momentum orbit correction (dpp) : -0.000166206
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.19
    Hall C energy (hallc_MeV) : 5710.99
    Delta(E)/E width (MV_AI_DXWID) : 1.1834
    IPM1C12.XPOS : 0.638159
    IPM1H04A.XPOS : -1.14609
    IPM1H04A.YPOS : 1.24349
    IPM1H04B.XPOS : -1.79935
    IPM1H04B.YPOS : 1.91632
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.29834
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.315918
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.5586
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.57267
    SLI vert. size mm : 0
    SLI y position : 0.991549
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.34
    temperature loop 1(2) : 104.97
    temperature loop 1(3) : 99.72
    temperature loop 3(1) : 19.43
    temperature loop 3(2) : 19.41
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068
    -----