    Log entry time 12:36:08 on June 9, 2008

    Entry number 241720

    keyword=End_of_Run_2078
    End-of-run EPICS data for Run Number 2078 at Mon Jun 9 12:35:57 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.603884
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00434552
    Right Arm arm angle : 0.197
    HALLA:p : 1192.2
    HALLA:dpp : -0.000152705
    Tiefenbach Hall A energy : 1192.2
    Left Arm Top VDC Current : -2.83203
    Left Arm Bottom VDC Current : 0.830078
    -----
    Left Arm Q1 momentum : 0.603825
    Left Arm Q1 power supply : 454.276
    Left Arm Q1 gauss meter : 0.03911
    Left Arm Q2 gauss meter : -0.13722
    Left Arm Q2 power supply current : 260.014
    Left Arm Q2 momentum : 0.603842
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 200.136
    Left Arm D1 momentum : 0.603884
    Left Arm D1 NMR : 0.254289
    Left Arm Q3 gauss meter : 0.122959
    Left Arm Q3 power supply current : 240.402
    Left Arm Q3 momentum : 0.603844
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00259279
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.86e-05
    Right Arm Q2 power supply current : -0.000203357
    Right Arm Q2 momentum : -4.72519e-07
    Right Arm Q2 gauss meter : -0.0003003
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0279901
    Right Arm D1 momentum : 0.00434552
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0
    Right Arm Q3 momentum : 0.000166797
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 2.42037
    Current on Unser monitor : 14.5455
    Current on Upstream bcm : 2.39609
    Current on Downstream bcm : 2.44466
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.1087
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.19
    Hall A momentum orbit correction (dpp) : -0.000159499
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.19
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.19408
    IPM1C12.XPOS : 0.617394
    IPM1H04A.XPOS : -1.16148
    IPM1H04A.YPOS : 1.22996
    IPM1H04B.XPOS : -1.79292
    IPM1H04B.YPOS : 1.88302
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.296875
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.31543
    -----
    Right Arm Collimator : -0.00825195
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.56646
    SLI vert. size mm : 0
    SLI y position : 1.68263
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 6.5
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.37
    temperature loop 1(2) : 105.01
    temperature loop 1(3) : 99.62
    temperature loop 3(1) : 19.37
    temperature loop 3(2) : 19.35
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.6
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----