keyword=changes to kine 3
At 14:00 we finished kinematics #1 at delta = +2 %.
We obtained 50 M events.
14:00 We asked for access to change the bigbite angle to 35 degrees
in preparation for next kinematics.
We did the following to prepare for kinematics #3, delta = +2%.
(A main goal here is to recover some Alum. dummy running that
was not done before.)
Change Left HRS P0 to 0.6955. Cycled Quads Q2 and Q3.
Put L-HRS angle to 53 degrees.
Took out 1.5" FPP door and put in 3" door. (The 3/4" door remains
as is. Note, there is no readback of the 3/4" door so we take it
on faith that it's in).
Guy and Brad went into the hall to change bigbite to 35 degrees.