Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:15:31 on June 9, 2008

    Entry number 241730

    keyword=End_of_Run_2079
    ****************************
     Run Number: 2079
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6039,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.4,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=closed,fppdoor_3=open,fppdoor_6=open,fppdoor_9=open,comment_text=K1 delta=2 production
     
    
    PRESCALE FACTORS:ps1=1500   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5006813      [+]: 2466326      [-]: 2466242      
    TIME     : [0]: 38.654 mins  [+]: 19.077 mins  [-]: 19.079 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.71835 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  39.84%      [+]:  39.96%      [-]:  39.97%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :22.8/34166.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :21.5/6452.9 Hz   T4[0] : 5.0/15106.1 Hz   T5[0] :3543.3/3543.3 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :22.8/34186.8 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :21.5/6453.6 Hz   T4[+] : 5.0/15108.4 Hz   T5[+] :3543.8/3543.8 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :22.8/34162.2 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :21.5/6453.7 Hz   T4[-] : 5.0/15108.5 Hz   T5[-] :3543.9/3543.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  52827/79241570  T2[0] :      0/0        T3[0] :  49886/14965909  T4[0] :  11678/35035025  T5[0] :8217930/8217930  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  23749/2374920  
    T1[+] :  26087/39131046  T2[+] :      0/0        T3[+] :  24623/7386982  T4[+] :   5764/17293378  T5[+] :4056301/4056301  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11720/1172094  
    T1[-] :  26070/39106327  T2[-] :      0/0        T3[-] :  24625/7387729  T4[-] :   5765/17295040  T5[-] :4056827/4056827  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11721/1172197  
    
    AVERAGE CURRENT
    BCM x1 : 2.4469 uA  BCM x3 : 2.4506 uA  BCM x10: 1.2253 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -42.15 ppm     BCM u3 :    55.31 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -76.57 ppm     BCM d3 :    57.29 ppm     BCM d10:    97.23 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.00569        BCM u3 [0]:0.005695       BCM u10[0]:-4.32E-05      
    BCM u1 [+]:0.002809       BCM u3 [+]:0.002811       BCM u10[+]:-2.132E-05     
    BCM u1 [-]:0.002809       BCM u3 [-]:0.002811       BCM u10[-]:-2.132E-05     
    
    BCM d1 [0]:0.00566        BCM d3 [0]:0.005673       BCM d10[0]:0.005727       
    BCM d1 [+]:0.002794       BCM d3 [+]:0.0028         BCM d10[+]:0.002827       
    BCM d1 [-]:0.002794       BCM d3 [-]:0.0028         BCM d10[-]:0.002827       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2079 at Mon Jun 9 14:15:20 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695499
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00438585
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -1.12305
    Left Arm Bottom VDC Current : 4.00391
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15795
    Left Arm Q2 power supply current : 299.542
    Left Arm Q2 momentum : 0.695639
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.237
    Left Arm D1 momentum : 0.695499
    Left Arm D1 NMR : 0.292905
    Left Arm Q3 gauss meter : 0.141366
    Left Arm Q3 power supply current : 276.915
    Left Arm Q3 momentum : 0.695561
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00267232
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.22e-05
    Right Arm Q2 power supply current : -0.000251423
    Right Arm Q2 momentum : -5.84205e-07
    Right Arm Q2 gauss meter : -0.0002914
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0254096
    Right Arm D1 momentum : 0.00438776
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000179343
    Right Arm Q3 momentum : 0.000167357
    Right Arm Q3 gauss meter : -0.0002707
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 0.0249081
    Current on Unser monitor : 11.7197
    Current on Upstream bcm : 0.0346036
    Current on Downstream bcm : 0.0152125
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 58.1563
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.17845
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.306641
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.324707
    -----
    Right Arm Collimator : -0.00864258
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.5586
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.0795
    SLI vert. size mm : 0
    SLI y position : 0.923944
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 2.5
    Encoder position : 1.70827e+07
    Target type : 1.70827e+07
    temperature loop 1(1) : 105.44
    temperature loop 1(2) : 105.08
    temperature loop 1(3) : 99.41
    temperature loop 3(1) : 19.16
    temperature loop 3(2) : 19.14
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.4
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----