    keyword=End_of_Run_2080
    ****************************
     Run Number: 2080
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine3 delta=2 trigger test
     
    
    PRESCALE FACTORS:ps1=30000   ps2=16777215   ps3=150   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 778878       [+]: 383802       [-]: 383650       
    TIME     : [0]: 7.785 mins  [+]: 3.871 mins  [-]: 3.870 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.79807 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  30.17%      [+]:  30.85%      [-]:  30.74%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :19.9/597612.4 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :23.6/3542.6 Hz   T4[0] : 4.7/9328.7 Hz   T5[0] :2345.2/2345.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :19.9/597549.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :23.6/3544.7 Hz   T4[+] : 4.7/9338.1 Hz   T5[+] :2347.1/2347.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :19.9/597476.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :23.6/3540.1 Hz   T4[-] : 4.7/9318.0 Hz   T5[-] :2342.8/2342.8 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   9305/279159718  T2[0] :      0/0        T3[0] :  11032/1654821  T4[0] :   2178/4357664  T5[0] :1095499/1095499  T6[0] :      0/0        T7[0] :      0/0        T8[0] :   4783/478336   
    T1[+] :   4626/138793802  T2[+] :      0/0        T3[+] :   5488/823343   T4[+] :   1084/2168963  T5[+] : 545166/545166   T6[+] :      0/0        T7[+] :      0/0        T8[+] :   2378/237846   
    T1[-] :   4624/138745881  T2[-] :      0/0        T3[-] :   5480/822076   T4[-] :   1081/2163820  T5[-] : 544044/544044   T6[-] :      0/0        T7[-] :      0/0        T8[-] :   2377/237793   
    
    AVERAGE CURRENT
    BCM x1 : 4.1150 uA  BCM x3 : 4.1190 uA  BCM x10: 2.0653 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -32.6 ppm     BCM u3 :    29.01 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -65.66 ppm     BCM d3 :    29.75 ppm     BCM d10:     54.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001927       BCM u3 [0]:0.001928       BCM u10[0]:-8.694E-06     
    BCM u1 [+]:0.000958       BCM u3 [+]:0.0009587      BCM u10[+]:-4.324E-06     
    BCM u1 [-]:0.0009579      BCM u3 [-]:0.0009584      BCM u10[-]:-4.321E-06     
    
    BCM d1 [0]:0.001917       BCM d3 [0]:0.00192        BCM d10[0]:0.001938       
    BCM d1 [+]:0.0009531      BCM d3 [+]:0.0009544      BCM d10[+]:0.0009636      
    BCM d1 [-]:0.000953       BCM d3 [-]:0.0009542      BCM d10[-]:0.0009633      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2080 at Mon Jun 9 14:36:54 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695493
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00433625
    Right Arm arm angle : 0.197
    HALLA:p : 1192.15
    HALLA:dpp : -0.000193726
    Tiefenbach Hall A energy : 1192.15
    Left Arm Top VDC Current : 0.683594
    Left Arm Bottom VDC Current : 3.125
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15798
    Left Arm Q2 power supply current : 299.544
    Left Arm Q2 momentum : 0.695644
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.251
    Left Arm D1 momentum : 0.695493
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141344
    Left Arm Q3 power supply current : 276.917
    Left Arm Q3 momentum : 0.695565
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00312831
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.27e-05
    Right Arm Q2 power supply current : 8.13427e-05
    Right Arm Q2 momentum : 0.00122116
    Right Arm Q2 gauss meter : -0.0002874
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.023874
    Right Arm D1 momentum : 0.00433625
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000119562
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002704
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 4.01911
    Current on Unser monitor : 15.8406
    Current on Upstream bcm : 3.96455
    Current on Downstream bcm : 4.07368
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.6979
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.13
    Hall A momentum orbit correction (dpp) : -0.000209037
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.13
    Hall C energy (hallc_MeV) : 5711
    Delta(E)/E width (MV_AI_DXWID) : 1.15079
    IPM1C12.XPOS : 0.785088
    IPM1H04A.XPOS : -1.14217
    IPM1H04A.YPOS : 1.2621
    IPM1H04B.XPOS : -1.79258
    IPM1H04B.YPOS : 1.93328
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.306641
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.327148
    -----
    Right Arm Collimator : -0.00859375
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.5586
    HacR_HPE1313A:0_Ch54 : -0.839844
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 92
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.02857
    SLI vert. size mm : 0
    SLI y position : 2.59906
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.42
    temperature loop 1(2) : 105.06
    temperature loop 1(3) : 99.39
    temperature loop 3(1) : 19.57
    temperature loop 3(2) : 19.55
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.9
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----