    Log entry time 16:11:30 on June 9, 2008

    Entry number 241755

    keyword=End_of_Run_2084
    ****************************
     Run Number: 2084
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine3 delta=2
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5003110      [+]: 2463461      [-]: 2465585      
    TIME     : [0]: 39.687 mins  [+]: 19.594 mins  [-]: 19.592 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.50985 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  37.57%      [+]:  37.71%      [-]:  37.72%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :20.6/41214.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :21.7/6497.4 Hz   T4[0] : 5.5/16357.1 Hz   T5[0] :3320.6/3320.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :20.6/41219.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :21.7/6497.5 Hz   T4[+] : 5.5/16356.3 Hz   T5[+] :3319.3/3319.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :20.6/41219.8 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :21.7/6499.3 Hz   T4[-] : 5.5/16362.0 Hz   T5[-] :3322.6/3322.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  49070/98141964  T2[0] :      0/0        T3[0] :  51573/15471906  T4[0] :  12983/38950329  T5[0] :7907204/7907204  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24383/2438399  
    T1[+] :  24229/48459021  T2[+] :      0/0        T3[+] :  25461/7638558  T4[+] :   6409/19228807  T5[+] :3902228/3902228  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12038/1203836  
    T1[-] :  24227/48454679  T2[-] :      0/0        T3[-] :  25466/7640088  T4[-] :   6411/19233906  T5[-] :3905832/3905832  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12037/1203732  
    
    AVERAGE CURRENT
    BCM x1 : 7.7926 uA  BCM x3 : 7.7966 uA  BCM x10: 3.9171 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -221.2 ppm     BCM u3 :   -187.6 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -234.1 ppm     BCM d3 :   -185.2 ppm     BCM d10:   -173.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0186         BCM u3 [0]:0.01861        BCM u10[0]:-4.435E-05     
    BCM u1 [+]:0.009181       BCM u3 [+]:0.009186       BCM u10[+]:-2.19E-05      
    BCM u1 [-]:0.009184       BCM u3 [-]:0.009188       BCM u10[-]:-2.189E-05     
    
    BCM d1 [0]:0.01851        BCM d3 [0]:0.01852        BCM d10[0]:0.0187         
    BCM d1 [+]:0.009139       BCM d3 [+]:0.009145       BCM d10[+]:0.009232       
    BCM d1 [-]:0.009143       BCM d3 [-]:0.009147       BCM d10[-]:0.009234       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2084 at Mon Jun 9 16:11:17 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695492
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.0043864
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000191502
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : -2.7832
    Left Arm Bottom VDC Current : -0.976562
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15798
    Left Arm Q2 power supply current : 299.544
    Left Arm Q2 momentum : 0.695644
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695492
    Left Arm D1 NMR : 0.292901
    Left Arm Q3 gauss meter : 0.141333
    Left Arm Q3 power supply current : 276.918
    Left Arm Q3 momentum : 0.695566
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00354719
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.69e-05
    Right Arm Q2 power supply current : -0.000336463
    Right Arm Q2 momentum : -7.81804e-07
    Right Arm Q2 gauss meter : -0.000294
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0279125
    Right Arm D1 momentum : 0.00438067
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.00010088
    Right Arm Q3 momentum : 0.000170156
    Right Arm Q3 gauss meter : -0.0002703
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 8.32941
    Current on Unser monitor : 20.6218
    Current on Upstream bcm : 8.17041
    Current on Downstream bcm : 8.46069
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.8102
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.000189265
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5711
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.760596
    IPM1H04A.XPOS : -1.14252
    IPM1H04A.YPOS : 1.24298
    IPM1H04B.XPOS : -1.80987
    IPM1H04B.YPOS : 1.90697
    -----
    Left Arm Collimator : 0.871143
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.332031
    -----
    Right Arm Collimator : -0.00883789
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.5098
    HacR_HPE1313A:0_Ch54 : -0.841309
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 111
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.37143
    SLI vert. size mm : 0
    SLI y position : 1.05164
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 6
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.37
    temperature loop 1(2) : 105.01
    temperature loop 1(3) : 99.63
    temperature loop 3(1) : 19.42
    temperature loop 3(2) : 19.4
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.0170928
    -----