Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:38:30 on June 9, 2008

    Entry number 241763

    keyword=End_of_Run_2086
    ****************************
     Run Number: 2086
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine3 delta=2
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5006574      [+]: 2466029      [-]: 2466353      
    TIME     : [0]: 42.164 mins  [+]: 20.806 mins  [-]: 20.805 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.79644 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  37.01%      [+]:  37.15%      [-]:  37.10%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :19.2/38464.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :20.2/6065.4 Hz   T4[0] : 5.1/15295.7 Hz   T5[0] :3099.1/3099.1 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :19.2/38471.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :20.2/6067.2 Hz   T4[+] : 5.1/15296.0 Hz   T5[+] :3100.4/3100.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :19.2/38469.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :20.2/6065.3 Hz   T4[-] : 5.1/15298.6 Hz   T5[-] :3098.4/3098.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  48653/97307326  T2[0] :      0/0        T3[0] :  51148/15344528  T4[0] :  12898/38695396  T5[0] :7840072/7840072  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  25905/2590544  
    T1[+] :  24013/48026474  T2[+] :      0/0        T3[+] :  25246/7573965  T4[+] :   6364/19094846  T5[+] :3870410/3870410  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12783/1278313  
    T1[-] :  24011/48022697  T2[-] :      0/0        T3[-] :  25238/7571518  T4[-] :   6365/19097587  T5[-] :3867749/3867749  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12782/1278285  
    
    AVERAGE CURRENT
    BCM x1 : 7.2623 uA  BCM x3 : 7.2668 uA  BCM x10: 3.6500 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -96.16 ppm     BCM u3 :   -57.14 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -108.4 ppm     BCM d3 :   -57.51 ppm     BCM d10:   -46.19 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01842        BCM u3 [0]:0.01843        BCM u10[0]:-4.71E-05      
    BCM u1 [+]:0.009089       BCM u3 [+]:0.009094       BCM u10[+]:-2.324E-05     
    BCM u1 [-]:0.00909        BCM u3 [-]:0.009095       BCM u10[-]:-2.324E-05     
    
    BCM d1 [0]:0.01833        BCM d3 [0]:0.01834        BCM d10[0]:0.01851        
    BCM d1 [+]:0.009045       BCM d3 [+]:0.009052       BCM d10[+]:0.009138       
    BCM d1 [-]:0.009046       BCM d3 [-]:0.009052       BCM d10[-]:0.009138       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2086 at Mon Jun 9 17:38:19 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00437686
    Right Arm arm angle : 0.197
    HALLA:p : 1192.17
    HALLA:dpp : -0.00018011
    Tiefenbach Hall A energy : 1192.17
    Left Arm Top VDC Current : 3.56445
    Left Arm Bottom VDC Current : -1.51367
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15799
    Left Arm Q2 power supply current : 299.543
    Left Arm Q2 momentum : 0.695642
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.267
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141347
    Left Arm Q3 power supply current : 276.917
    Left Arm Q3 momentum : 0.695563
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00311241
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.44e-05
    Right Arm Q2 power supply current : -0.000140501
    Right Arm Q2 momentum : -3.26468e-07
    Right Arm Q2 gauss meter : -0.0002884
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0273582
    Right Arm D1 momentum : 0.00438776
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 2.24178e-05
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 8.07756
    Current on Unser monitor : 19.1606
    Current on Upstream bcm : 7.97462
    Current on Downstream bcm : 8.1805
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.2045
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.18
    Hall A momentum orbit correction (dpp) : -0.000174889
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.18
    Hall C energy (hallc_MeV) : 5710.99
    Delta(E)/E width (MV_AI_DXWID) : 1.18438
    IPM1C12.XPOS : 0.706823
    IPM1H04A.XPOS : -1.15569
    IPM1H04A.YPOS : 1.259
    IPM1H04B.XPOS : -1.79873
    IPM1H04B.YPOS : 1.93488
    -----
    Left Arm Collimator : 0.871143
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9746
    HacL_HPE1313A:0_Ch54 : -0.333008
    -----
    Right Arm Collimator : -0.00878906
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 111
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.968944
    SLI vert. size mm : 0
    SLI y position : 3.59061
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 1
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.25
    temperature loop 1(2) : 104.89
    temperature loop 1(3) : 99.24
    temperature loop 3(1) : 19.42
    temperature loop 3(2) : 19.41
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00293052
    -----