Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:03:07 on June 9, 2008

    Entry number 241768

    keyword=End_of_Run_2088
    ****************************
     Run Number: 2088
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine3 delta=2
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5003815      [+]: 2464001      [-]: 2465922      
    TIME     : [0]: 41.027 mins  [+]: 20.247 mins  [-]: 20.245 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.75411 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  37.24%      [+]:  37.35%      [-]:  37.34%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :19.8/39657.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :20.8/6251.2 Hz   T4[0] : 5.2/15626.6 Hz   T5[0] :3195.3/3195.3 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :19.8/39648.5 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :20.8/6248.1 Hz   T4[+] : 5.2/15624.0 Hz   T5[+] :3194.2/3194.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :19.8/39664.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :20.8/6254.6 Hz   T4[-] : 5.2/15629.3 Hz   T5[-] :3196.0/3196.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  48810/97621217  T2[0] :      0/0        T3[0] :  51294/15388277  T4[0] :  12822/38467056  T5[0] :7865620/7865620  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  25207/2520717  
    T1[+] :  24082/48164613  T2[+] :      0/0        T3[+] :  25300/7590118  T4[+] :   6326/18979932  T5[+] :3880282/3880282  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12439/1243945  
    T1[-] :  24090/48181553  T2[-] :      0/0        T3[-] :  25325/7597610  T4[-] :   6328/18985391  T5[-] :3882322/3882322  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12438/1243883  
    
    AVERAGE CURRENT
    BCM x1 : 7.4823 uA  BCM x3 : 7.4875 uA  BCM x10: 3.7668 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -240.8 ppm     BCM u3 :   -200.5 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -251.6 ppm     BCM d3 :   -200.3 ppm     BCM d10:   -189.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01844        BCM u3 [0]:0.01845        BCM u10[0]:-4.581E-05     
    BCM u1 [+]:0.009096       BCM u3 [+]:0.009102       BCM u10[+]:-2.261E-05     
    BCM u1 [-]:0.0091         BCM u3 [-]:0.009105       BCM u10[-]:-2.26E-05      
    
    BCM d1 [0]:0.0184         BCM d3 [0]:0.01842        BCM d10[0]:0.01859        
    BCM d1 [+]:0.009078       BCM d3 [+]:0.009086       BCM d10[+]:0.009173       
    BCM d1 [-]:0.009083       BCM d3 [-]:0.009089       BCM d10[-]:0.009176       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2088 at Mon Jun 9 19:02:56 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695493
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00433489
    Right Arm arm angle : 0.197
    HALLA:p : 1192.17
    HALLA:dpp : -0.000178199
    Tiefenbach Hall A energy : 1192.17
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : 3.61328
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15796
    Left Arm Q2 power supply current : 299.542
    Left Arm Q2 momentum : 0.69564
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695493
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.14133
    Left Arm Q3 power supply current : 276.917
    Left Arm Q3 momentum : 0.695564
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00426829
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001005
    Right Arm Q2 power supply current : -0.000373437
    Right Arm Q2 momentum : -8.67716e-07
    Right Arm Q2 gauss meter : -0.0002857
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.027157
    Right Arm D1 momentum : 0.00432889
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -5.23083e-05
    Right Arm Q3 momentum : 0.000166797
    Right Arm Q3 gauss meter : -0.0002702
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 7.84204
    Current on Unser monitor : 20.3166
    Current on Upstream bcm : 7.72655
    Current on Downstream bcm : 7.95752
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 82.3373
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.000186059
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.15373
    IPM1C12.XPOS : 0.71047
    IPM1H04A.XPOS : -1.14554
    IPM1H04A.YPOS : 1.1931
    IPM1H04B.XPOS : -1.79349
    IPM1H04B.YPOS : 1.84193
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.333496
    -----
    Right Arm Collimator : -0.00820313
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.839844
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 109
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.901863
    SLI vert. size mm : 0
    SLI y position : 1.10423
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 4.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.24
    temperature loop 1(2) : 104.88
    temperature loop 1(3) : 99.08
    temperature loop 3(1) : 19.44
    temperature loop 3(2) : 19.42
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00634721
    -----