Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:01:23 on June 9, 2008

    Entry number 241775

    keyword=End_of_Run_2090
    ****************************
     Run Number: 2090
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Kine3 delta=2
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 1511046      [+]: 744467       [-]: 744328       
    TIME     : [0]: 14.324 mins  [+]: 7.092 mins  [-]: 7.091 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.12732 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  37.21%      [+]:  37.54%      [-]:  37.64%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.1/34215.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :18.0/5410.1 Hz   T4[0] : 4.6/13765.0 Hz   T5[0] :2761.0/2761.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.1/34245.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :18.1/5417.9 Hz   T4[+] : 4.6/13779.4 Hz   T5[+] :2762.2/2762.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.1/34265.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :18.0/5414.9 Hz   T4[-] : 4.6/13781.4 Hz   T5[-] :2766.5/2766.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14703/29406747  T2[0] :      0/0        T3[0] :  15499/4649751  T4[0] :   3943/11830494  T5[0] :2372943/2372943  T6[0] :      0/0        T7[0] :      0/0        T8[0] :   8800/880091   
    T1[+] :   7285/14571540  T2[+] :      0/0        T3[+] :   7684/2305348  T4[+] :   1954/5863263  T5[+] :1175347/1175347  T6[+] :      0/0        T7[+] :      0/0        T8[+] :   4357/435720   
    T1[-] :   7289/14578879  T2[-] :      0/0        T3[-] :   7679/2303855  T4[-] :   1954/5863527  T5[-] :1177041/1177041  T6[-] :      0/0        T7[-] :      0/0        T8[-] :   4356/435679   
    
    AVERAGE CURRENT
    BCM x1 : 6.4955 uA  BCM x3 : 6.5006 uA  BCM x10: 3.2690 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -272.4 ppm     BCM u3 :   -221.6 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -283.6 ppm     BCM d3 :   -222.8 ppm     BCM d10:   -209.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005588       BCM u3 [0]:0.005592       BCM u10[0]:-1.601E-05     
    BCM u1 [+]:0.002769       BCM u3 [+]:0.002771       BCM u10[+]:-7.928E-06     
    BCM u1 [-]:0.00277        BCM u3 [-]:0.002772       BCM u10[-]:-7.927E-06     
    
    BCM d1 [0]:0.005578       BCM d3 [0]:0.005582       BCM d10[0]:0.005635       
    BCM d1 [+]:0.002764       BCM d3 [+]:0.002766       BCM d10[+]:0.002793       
    BCM d1 [-]:0.002765       BCM d3 [-]:0.002767       BCM d10[-]:0.002794       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2090 at Mon Jun 9 20:01:12 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695492
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00435751
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000190529
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : 1.2207
    Left Arm Bottom VDC Current : -2.09961
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15802
    Left Arm Q2 power supply current : 299.544
    Left Arm Q2 momentum : 0.695643
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695492
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141351
    Left Arm Q3 power supply current : 276.918
    Left Arm Q3 momentum : 0.695566
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00364263
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.87e-05
    Right Arm Q2 power supply current : -0.000195962
    Right Arm Q2 momentum : -2.0619e-07
    Right Arm Q2 gauss meter : -0.0002937
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.02757
    Right Arm D1 momentum : 0.00435751
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 2.98904e-05
    Right Arm Q3 momentum : 0.000164558
    Right Arm Q3 gauss meter : -0.0002706
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 8.03839
    Current on Unser monitor : 19.0598
    Current on Upstream bcm : 7.91588
    Current on Downstream bcm : 8.1609
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.2332
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.00019024
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.776675
    IPM1H04A.XPOS : -1.15352
    IPM1H04A.YPOS : 1.22222
    IPM1H04B.XPOS : -1.79979
    IPM1H04B.YPOS : 1.88942
    -----
    Left Arm Collimator : 0.871143
    HacL_HPE1313A:0_Ch58 : -0.306152
    HacL_HPE1313A:0_Ch55 : 23.9746
    HacL_HPE1313A:0_Ch54 : -0.334961
    -----
    Right Arm Collimator : -0.00883789
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 109
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.83354
    SLI vert. size mm : 0
    SLI y position : 3.48545
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.24
    temperature loop 1(2) : 104.87
    temperature loop 1(3) : 99.3
    temperature loop 3(1) : 19.85
    temperature loop 3(2) : 19.83
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----