Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:13:14 on June 9, 2008

    Entry number 241779

    keyword=End_of_Run_2091
    ****************************
     Run Number: 2091
     End of Run Comment:
    Run_type=Other,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Pedestal run (ps8=1), 1uA
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1000   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 271571       [+]: 133751       [-]: 133798       
    TIME     : [0]: 4.399 mins  [+]: 2.203 mins  [-]: 2.203 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.64483 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   0.26%      [+]:   1.97%      [-]:   1.90%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.4/6837.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 3.0/907.7 Hz   T4[0] : 1.2/3492.7 Hz   T5[0] : 0.1/102.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] : 3.7/7475.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 3.1/925.9 Hz   T4[+] : 1.2/3534.0 Hz   T5[+] : 0.1/112.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] : 3.7/7487.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 3.1/923.2 Hz   T4[-] : 1.2/3524.6 Hz   T5[-] : 0.1/111.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    902/1804826  T2[0] :      0/0        T3[0] :    798/239581   T4[0] :    307/921898   T5[0] :     26/26965    T6[0] :      0/0        T7[0] :      0/0        T8[0] : 270282/270282   
    T1[+] :    494/988255   T2[+] :      0/0        T3[+] :    408/122413   T4[+] :    155/467207   T5[+] :     14/14861    T6[+] :      0/0        T7[+] :      0/0        T8[+] : 135377/135377   
    T1[-] :    494/989483   T2[-] :      0/0        T3[-] :    406/122004   T4[-] :    155/465805   T5[-] :     14/14786    T6[-] :      0/0        T7[-] :      0/0        T8[-] : 135330/135330   
    
    AVERAGE CURRENT
    BCM x1 : 0.9713 uA  BCM x3 : 0.9759 uA  BCM x10: 0.4834 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     -610 ppm     BCM u3 :   -361.3 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -632.9 ppm     BCM d3 :   -337.8 ppm     BCM d10:     -259 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0002569      BCM u3 [0]:0.0002575      BCM u10[0]:-4.915E-06     
    BCM u1 [+]:0.0001311      BCM u3 [+]:0.0001315      BCM u10[+]:-2.462E-06     
    BCM u1 [-]:0.0001313      BCM u3 [-]:0.0001315      BCM u10[-]:-2.461E-06     
    
    BCM d1 [0]:0.0002558      BCM d3 [0]:0.0002577      BCM d10[0]:0.0002601      
    BCM d1 [+]:0.0001306      BCM d3 [+]:0.0001316      BCM d10[+]:0.0001328      
    BCM d1 [-]:0.0001307      BCM d3 [-]:0.0001316      BCM d10[-]:0.0001328      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2091 at Mon Jun 9 20:13:02 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695491
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00432698
    Right Arm arm angle : 0.197
    HALLA:p : 1192.14
    HALLA:dpp : -0.000201313
    Tiefenbach Hall A energy : 1192.14
    Left Arm Top VDC Current : 3.90625
    Left Arm Bottom VDC Current : 1.85547
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.158
    Left Arm Q2 power supply current : 299.545
    Left Arm Q2 momentum : 0.695644
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.263
    Left Arm D1 momentum : 0.695492
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141351
    Left Arm Q3 power supply current : 276.918
    Left Arm Q3 momentum : 0.695567
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00320255
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.47e-05
    Right Arm Q2 power supply current : -6.65531e-05
    Right Arm Q2 momentum : -1.54643e-07
    Right Arm Q2 gauss meter : -0.0002907
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0268146
    Right Arm D1 momentum : 0.00432998
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000104617
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002705
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.162
    Current on Unser monitor : 13.325
    Current on Upstream bcm : 2.13124
    Current on Downstream bcm : 2.19276
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 78.4868
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.15
    Hall A momentum orbit correction (dpp) : -0.000197812
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.15
    Hall C energy (hallc_MeV) : 5710.99
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.716795
    IPM1H04A.XPOS : -1.19802
    IPM1H04A.YPOS : 1.35492
    IPM1H04B.XPOS : -1.8385
    IPM1H04B.YPOS : 2.08519
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.305176
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.334473
    -----
    Right Arm Collimator : -0.00874023
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.5586
    HacR_HPE1313A:0_Ch54 : -0.839844
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.01988
    SLI vert. size mm : 0
    SLI y position : 1.54742
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 1.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.25
    temperature loop 1(2) : 104.89
    temperature loop 1(3) : 99.37
    temperature loop 3(1) : 19.25
    temperature loop 3(2) : 19.23
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.6
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00293052
    -----