     Run Number: 2093
     End of Run Comment:
    Run_type=Other,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Pedestal run (ps8=1), 2 uA, set v792 internal ped to min
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=300   ps4=3000   ps5=1000   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 58930        [+]: 29052        [-]: 29006        
    TIME     : [0]: 0.943 mins  [+]: 0.501 mins  [-]: 0.501 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.53960 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   1.01%      [+]:   8.40%      [-]:   8.50%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :20.4/40841.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 5.6/1690.5 Hz   T4[0] : 1.7/5155.7 Hz   T5[0] : 0.6/609.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] :22.3/44698.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 5.7/1695.4 Hz   T4[+] : 1.7/5173.3 Hz   T5[+] : 0.6/640.0 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] :22.3/44622.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 5.7/1697.8 Hz   T4[-] : 1.7/5180.8 Hz   T5[-] : 0.6/645.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1155/2310671  T2[0] :      0/0        T3[0] :    318/95641    T4[0] :     97/291689   T5[0] :     34/34456    T6[0] :      0/0        T7[0] :      0/0        T8[0] :  57934/57934    
    T1[+] :    672/1344661  T2[+] :      0/0        T3[+] :    170/51004    T4[+] :     51/155627   T5[+] :     19/19252    T6[+] :      0/0        T7[+] :      0/0        T8[+] :  30805/30805    
    T1[-] :    670/1341817  T2[-] :      0/0        T3[-] :    170/51052    T4[-] :     51/155788   T5[-] :     19/19413    T6[-] :      0/0        T7[-] :      0/0        T8[-] :  30792/30792    
    
    AVERAGE CURRENT
    BCM x1 : 1.8862 uA  BCM x3 : 1.8913 uA  BCM x10: 0.9449 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -102.5 ppm     BCM u3 :   -80.91 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -290.8 ppm     BCM d3 :   -45.25 ppm     BCM d10:    -26.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0001069      BCM u3 [0]:0.000107       BCM u10[0]:-1.053E-06     
    BCM u1 [+]:5.71E-05       BCM u3 [+]:5.718E-05      BCM u10[+]:-5.602E-07     
    BCM u1 [-]:5.709E-05      BCM u3 [-]:5.716E-05      BCM u10[-]:-5.6E-07       
    
    BCM d1 [0]:0.0001065      BCM d3 [0]:0.000107       BCM d10[0]:0.000108       
    BCM d1 [+]:5.689E-05      BCM d3 [+]:5.713E-05      BCM d10[+]:5.768E-05      
    BCM d1 [-]:5.69E-05       BCM d3 [-]:5.711E-05      BCM d10[-]:5.766E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2093 at Mon Jun 9 20:21:35 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695492
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00432998
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000189722
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : -0.0976562
    Left Arm Bottom VDC Current : -1.17188
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15802
    Left Arm Q2 power supply current : 299.545
    Left Arm Q2 momentum : 0.695645
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.267
    Left Arm D1 momentum : 0.695492
    Left Arm D1 NMR : 0.292901
    Left Arm Q3 gauss meter : 0.141348
    Left Arm Q3 power supply current : 276.919
    Left Arm Q3 momentum : 0.695568
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00406151
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001049
    Right Arm Q2 power supply current : -5.17635e-05
    Right Arm Q2 momentum : -1.20278e-07
    Right Arm Q2 gauss meter : -0.00029
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.025985
    Right Arm D1 momentum : 0.00432126
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002703
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.04421
    Current on Unser monitor : 12.8626
    Current on Upstream bcm : 1.99811
    Current on Downstream bcm : 2.04851
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 77.7046
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.17
    Hall A momentum orbit correction (dpp) : -0.000182557
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.17
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.719754
    IPM1H04A.XPOS : -1.15781
    IPM1H04A.YPOS : 1.24397
    IPM1H04B.XPOS : -1.79686
    IPM1H04B.YPOS : 1.91814
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.334473
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.563477
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 79
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.57888
    SLI vert. size mm : 0
    SLI y position : 2.99718
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.26
    temperature loop 1(2) : 104.9
    temperature loop 1(3) : 99.43
    temperature loop 3(1) : 19.14
    temperature loop 3(2) : 19.13
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.4
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----