     Run Number: 2095
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 2uA , BB_mag=700amps
     
    
    PRESCALE FACTORS:ps1=200   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 286701       [+]: 141395       [-]: 141117       
    TIME     : [0]: 3.913 mins  [+]: 1.962 mins  [-]: 1.962 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.49122 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  21.14%      [+]:  22.62%      [-]:  22.69%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :445.4/89082.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/1630.8 Hz   T4[0] : 0.0/5004.5 Hz   T5[0] :1006.1/1006.1 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :445.9/89172.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/1635.0 Hz   T4[+] : 0.0/5013.2 Hz   T5[+] :1008.8/1008.8 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :446.5/89307.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/1631.2 Hz   T4[-] : 0.0/5006.8 Hz   T5[-] :1006.7/1006.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 104561/20912241  T2[0] :      0/0        T3[0] :      0/382836   T4[0] :      0/1174800  T5[0] : 236175/236175   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24038/240385   
    T1[+] :  52498/10499653  T2[+] :      0/0        T3[+] :      0/192512   T4[+] :      0/590281   T5[+] : 118786/118786   T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12057/120572   
    T1[-] :  52570/10514049  T2[-] :      0/0        T3[-] :      0/192033   T4[-] :      0/589444   T5[-] : 118517/118517   T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12055/120554   
    
    AVERAGE CURRENT
    BCM x1 : 1.8287 uA  BCM x3 : 1.8333 uA  BCM x10: 0.9155 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -694.3 ppm     BCM u3 :   -462.1 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -649.3 ppm     BCM d3 :   -469.5 ppm     BCM d10:   -411.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0004301      BCM u3 [0]:0.0004306      BCM u10[0]:-4.372E-06     
    BCM u1 [+]:0.000216       BCM u3 [+]:0.0002163      BCM u10[+]:-2.193E-06     
    BCM u1 [-]:0.0002162      BCM u3 [-]:0.0002165      BCM u10[-]:-2.193E-06     
    
    BCM d1 [0]:0.0004285      BCM d3 [0]:0.0004301      BCM d10[0]:0.0004342      
    BCM d1 [+]:0.0002152      BCM d3 [+]:0.000216       BCM d10[+]:0.0002181      
    BCM d1 [-]:0.0002154      BCM d3 [-]:0.0002162      BCM d10[-]:0.0002182      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2095 at Mon Jun 9 20:33:39 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695491
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00438421
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000186739
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : 2.49023
    Left Arm Bottom VDC Current : 4.10156
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15802
    Left Arm Q2 power supply current : 299.543
    Left Arm Q2 momentum : 0.695642
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695491
    Left Arm D1 NMR : 0.292901
    Left Arm Q3 gauss meter : 0.141349
    Left Arm Q3 power supply current : 276.917
    Left Arm Q3 momentum : 0.695565
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00312831
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.29e-05
    Right Arm Q2 power supply current : -0.00026991
    Right Arm Q2 momentum : -6.27161e-07
    Right Arm Q2 gauss meter : -0.0002947
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0279936
    Right Arm D1 momentum : 0.00437549
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.00010088
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002706
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.0565
    Current on Unser monitor : 14.2216
    Current on Upstream bcm : 2.03413
    Current on Downstream bcm : 2.07887
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.4414
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.000186993
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5710.99
    Delta(E)/E width (MV_AI_DXWID) : 0.52223
    IPM1C12.XPOS : 0.752481
    IPM1H04A.XPOS : -1.16583
    IPM1H04A.YPOS : 1.25018
    IPM1H04B.XPOS : -1.81045
    IPM1H04B.YPOS : 1.93007
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.306152
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.333984
    -----
    Right Arm Collimator : -0.00820313
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.6562
    HacR_HPE1313A:0_Ch54 : -0.84082
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 79
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.27453
    SLI vert. size mm : 0
    SLI y position : 0.495775
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 3
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.24
    temperature loop 1(2) : 104.87
    temperature loop 1(3) : 99.34
    temperature loop 3(1) : 19.61
    temperature loop 3(2) : 19.59
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.9
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 0.00293052
    -----