Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:42:55 on June 9, 2008

    Entry number 241799

    keyword=End_of_Run_2097
    ****************************
     Run Number: 2097
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=500,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 2uA , BB_mag=500amps
     
    
    PRESCALE FACTORS:ps1=200   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 392752       [+]: 193130       [-]: 193758       
    TIME     : [0]: 4.712 mins  [+]: 2.357 mins  [-]: 2.356 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.56062 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  21.85%      [+]:  22.99%      [-]:  23.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :548.4/109675.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/1790.6 Hz   T4[0] : 0.0/4798.9 Hz   T5[0] :1132.4/1132.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :548.2/109642.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/1787.4 Hz   T4[+] : 0.0/4797.6 Hz   T5[+] :1128.8/1128.8 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :548.5/109700.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/1793.9 Hz   T4[-] : 0.0/4800.4 Hz   T5[-] :1135.7/1135.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 155050/31010025  T2[0] :      0/0        T3[0] :      0/506280   T4[0] :      0/1356871  T5[0] : 320189/320189   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  28953/289530   
    T1[+] :  77520/15504189  T2[+] :      0/0        T3[+] :      0/252750   T4[+] :      0/678418   T5[+] : 159614/159614   T6[+] :      0/0        T7[+] :      0/0        T8[+] :  14480/144801   
    T1[-] :  77543/15508627  T2[-] :      0/0        T3[-] :      0/253613   T4[-] :      0/678645   T5[-] : 160556/160556   T6[-] :      0/0        T7[-] :      0/0        T8[-] :  14476/144766   
    
    AVERAGE CURRENT
    BCM x1 : 2.0178 uA  BCM x3 : 2.0229 uA  BCM x10: 1.0111 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     -453 ppm     BCM u3 :     -294 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -483.5 ppm     BCM d3 :   -291.1 ppm     BCM d10:   -244.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0005716      BCM u3 [0]:0.0005723      BCM u10[0]:-5.262E-06     
    BCM u1 [+]:0.0002857      BCM u3 [+]:0.0002861      BCM u10[+]:-2.632E-06     
    BCM u1 [-]:0.0002859      BCM u3 [-]:0.0002862      BCM u10[-]:-2.631E-06     
    
    BCM d1 [0]:0.0005695      BCM d3 [0]:0.0005716      BCM d10[0]:0.000577       
    BCM d1 [+]:0.0002847      BCM d3 [+]:0.0002858      BCM d10[+]:0.0002885      
    BCM d1 [-]:0.0002849      BCM d3 [-]:0.0002859      BCM d10[-]:0.0002886      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2097 at Mon Jun 9 20:42:44 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00433162
    Right Arm arm angle : 0.197
    HALLA:p : 1192.15
    HALLA:dpp : -0.000192999
    Tiefenbach Hall A energy : 1192.15
    Left Arm Top VDC Current : 5.12695
    Left Arm Bottom VDC Current : 2.68555
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15802
    Left Arm Q2 power supply current : 299.545
    Left Arm Q2 momentum : 0.695645
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.264
    Left Arm D1 momentum : 0.695495
    Left Arm D1 NMR : 0.292903
    Left Arm Q3 gauss meter : 0.141359
    Left Arm Q3 power supply current : 276.919
    Left Arm Q3 momentum : 0.695568
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000768823
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -3.45e-05
    Right Arm Q2 power supply current : -0.000122014
    Right Arm Q2 momentum : -2.83511e-07
    Right Arm Q2 gauss meter : -0.000285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270511
    Right Arm D1 momentum : 0.00435206
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 2.98904e-05
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002702
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 500
    BigBite magnet current readback : 497.546
    BigBite Gaussmeter readback : 8500
    -----
    Average current of the two cavities : 2.01123
    Current on Unser monitor : 13.9584
    Current on Upstream bcm : 1.99119
    Current on Downstream bcm : 2.03127
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 77.9286
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.15
    Hall A momentum orbit correction (dpp) : -0.000194639
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.15
    Hall C energy (hallc_MeV) : 5710.99
    Delta(E)/E width (MV_AI_DXWID) : 0.52215
    IPM1C12.XPOS : 0.760669
    IPM1H04A.XPOS : -1.11163
    IPM1H04A.YPOS : 1.17736
    IPM1H04B.XPOS : -1.77496
    IPM1H04B.YPOS : 1.84047
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.333984
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.563477
    HacR_HPE1313A:0_Ch55 : 22.6562
    HacR_HPE1313A:0_Ch54 : -0.841309
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 79
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.819876
    SLI vert. size mm : 0
    SLI y position : 3.48545
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 2.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.23
    temperature loop 1(2) : 104.87
    temperature loop 1(3) : 99.05
    temperature loop 3(1) : 19.69
    temperature loop 3(2) : 19.67
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00634721
    -----