    keyword=End_of_Run_2099
    ****************************
     Run Number: 2099
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=100,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 2uA , BB_mag=100amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 454918       [+]: 223809       [-]: 224387       
    TIME     : [0]: 4.452 mins  [+]: 2.226 mins  [-]: 2.227 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.29519 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  23.48%      [+]:  24.78%      [-]:  24.69%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1111.5/111153.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/1633.7 Hz   T4[0] : 0.0/4427.5 Hz   T5[0] :1021.7/1021.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :1113.8/111377.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/1634.6 Hz   T4[+] : 0.0/4423.6 Hz   T5[+] :1022.1/1022.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :1112.9/111291.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/1638.9 Hz   T4[-] : 0.0/4441.2 Hz   T5[-] :1025.0/1025.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 296942/29694220  T2[0] :      0/0        T3[0] :      0/436433   T4[0] :      0/1182794  T5[0] : 272937/272937   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  27355/273558   
    T1[+] : 148752/14875283  T2[+] :      0/0        T3[+] :      0/218308   T4[+] :      0/590803   T5[+] : 136503/136503   T6[+] :      0/0        T7[+] :      0/0        T8[+] :  13676/136763   
    T1[-] : 148696/14869618  T2[-] :      0/0        T3[-] :      0/218977   T4[-] :      0/593384   T5[-] : 136948/136948   T6[-] :      0/0        T7[-] :      0/0        T8[-] :  13681/136816   
    
    AVERAGE CURRENT
    BCM x1 : 1.8251 uA  BCM x3 : 1.8302 uA  BCM x10: 0.9141 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    28.97 ppm     BCM u3 :    184.3 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    6.466 ppm     BCM d3 :    195.5 ppm     BCM d10:    247.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0004884      BCM u3 [0]:0.0004891      BCM u10[0]:-4.973E-06     
    BCM u1 [+]:0.0002446      BCM u3 [+]:0.000245       BCM u10[+]:-2.486E-06     
    BCM u1 [-]:0.0002447      BCM u3 [-]:0.000245       BCM u10[-]:-2.487E-06     
    
    BCM d1 [0]:0.0004867      BCM d3 [0]:0.0004888      BCM d10[0]:0.0004934      
    BCM d1 [+]:0.0002437      BCM d3 [+]:0.0002448      BCM d10[+]:0.0002471      
    BCM d1 [-]:0.0002438      BCM d3 [-]:0.0002448      BCM d10[-]:0.0002471      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2099 at Mon Jun 9 20:55:21 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695495
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.0043864
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000191838
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : -1.12305
    Left Arm Bottom VDC Current : 0.244141
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15796
    Left Arm Q2 power supply current : 299.544
    Left Arm Q2 momentum : 0.695642
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.265
    Left Arm D1 momentum : 0.695495
    Left Arm D1 NMR : 0.292903
    Left Arm Q3 gauss meter : 0.141353
    Left Arm Q3 power supply current : 276.918
    Left Arm Q3 momentum : 0.695566
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000212089
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -2.28e-05
    Right Arm Q2 power supply current : -0.000277305
    Right Arm Q2 momentum : -6.44344e-07
    Right Arm Q2 gauss meter : -0.0002921
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270723
    Right Arm D1 momentum : 0.00436159
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -7.84624e-05
    Right Arm Q3 momentum : -1.97187e-07
    Right Arm Q3 gauss meter : -0.0002698
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 100
    BigBite magnet current readback : 99.4484
    BigBite Gaussmeter readback : 1723
    -----
    Average current of the two cavities : 2.03323
    Current on Unser monitor : 13.77
    Current on Upstream bcm : 1.98843
    Current on Downstream bcm : 2.07803
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 78.2522
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.000190985
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 0.531162
    IPM1C12.XPOS : 0.752363
    IPM1H04A.XPOS : -1.15278
    IPM1H04A.YPOS : 1.19447
    IPM1H04B.XPOS : -1.80637
    IPM1H04B.YPOS : 1.86308
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.333984
    -----
    Right Arm Collimator : -0.00834961
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 79
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.790062
    SLI vert. size mm : 0
    SLI y position : 3.30516
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 3
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.25
    temperature loop 1(2) : 104.89
    temperature loop 1(3) : 99.2
    temperature loop 3(1) : 19.26
    temperature loop 3(2) : 19.25
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.7
    Heat exchange LH2 : 19.5
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00293052
    -----