Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:02:51 on June 9, 2008

    Entry number 241809

    keyword=End_of_Run_2100
    ****************************
     Run Number: 2100
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 2uA , BB_mag=0amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 554535       [+]: 273470       [-]: 272891       
    TIME     : [0]: 5.439 mins  [+]: 2.715 mins  [-]: 2.714 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.64992 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  24.21%      [+]:  25.31%      [-]:  25.30%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1124.2/112416.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/1636.4 Hz   T4[0] : 0.0/4441.0 Hz   T5[0] :1026.0/1026.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :1125.4/112541.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/1641.2 Hz   T4[+] : 0.0/4450.9 Hz   T5[+] :1030.0/1030.0 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :1126.2/112619.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/1636.0 Hz   T4[-] : 0.0/4437.7 Hz   T5[-] :1024.8/1024.8 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 366856/36685679  T2[0] :      0/0        T3[0] :      0/534011   T4[0] :      0/1449266  T5[0] : 334817/334817   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  33417/334170   
    T1[+] : 183348/18334835  T2[+] :      0/0        T3[+] :      0/267377   T4[+] :      0/725124   T5[+] : 167797/167797   T6[+] :      0/0        T7[+] :      0/0        T8[+] :  16682/166826   
    T1[-] : 183411/18341137  T2[-] :      0/0        T3[-] :      0/266446   T4[-] :      0/722726   T5[-] : 166897/166897   T6[-] :      0/0        T7[-] :      0/0        T8[-] :  16676/166768   
    
    AVERAGE CURRENT
    BCM x1 : 1.8300 uA  BCM x3 : 1.8350 uA  BCM x10: 0.9166 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -510.4 ppm     BCM u3 :   -373.4 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -601.6 ppm     BCM d3 :   -369.5 ppm     BCM d10:   -332.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0005982      BCM u3 [0]:0.000599       BCM u10[0]:-6.077E-06     
    BCM u1 [+]:0.0002989      BCM u3 [+]:0.0002994      BCM u10[+]:-3.033E-06     
    BCM u1 [-]:0.0002991      BCM u3 [-]:0.0002995      BCM u10[-]:-3.032E-06     
    
    BCM d1 [0]:0.0005962      BCM d3 [0]:0.0005986      BCM d10[0]:0.0006043      
    BCM d1 [+]:0.0002979      BCM d3 [+]:0.0002992      BCM d10[+]:0.0003021      
    BCM d1 [-]:0.0002982      BCM d3 [-]:0.0002993      BCM d10[-]:0.0003022      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2100 at Mon Jun 9 21:02:41 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00432426
    Right Arm arm angle : 0.197
    HALLA:p : 1192.14
    HALLA:dpp : -0.000201599
    Tiefenbach Hall A energy : 1192.14
    Left Arm Top VDC Current : 4.49219
    Left Arm Bottom VDC Current : 2.63672
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04486
    Left Arm Q2 gauss meter : -0.15797
    Left Arm Q2 power supply current : 299.542
    Left Arm Q2 momentum : 0.695639
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292903
    Left Arm Q3 gauss meter : 0.141347
    Left Arm Q3 power supply current : 276.916
    Left Arm Q3 momentum : 0.69556
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000408271
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -2.95e-05
    Right Arm Q2 power supply current : -5.54609e-05
    Right Arm Q2 momentum : -1.28869e-07
    Right Arm Q2 gauss meter : -0.0002856
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270899
    Right Arm D1 momentum : 0.00432426
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -5.60446e-05
    Right Arm Q3 momentum : -3.19255e-07
    Right Arm Q3 gauss meter : -0.0002703
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 13.937
    -----
    Average current of the two cavities : 2.07528
    Current on Unser monitor : 14.6134
    Current on Upstream bcm : 2.04271
    Current on Downstream bcm : 2.10784
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 78.1532
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.14
    Hall A momentum orbit correction (dpp) : -0.000208665
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.14
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 0.539699
    IPM1C12.XPOS : 0.815415
    IPM1H04A.XPOS : -1.14458
    IPM1H04A.YPOS : 1.22425
    IPM1H04B.XPOS : -1.78878
    IPM1H04B.YPOS : 1.90137
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.334473
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.84082
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 79
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.58882
    SLI vert. size mm : 0
    SLI y position : 3.67324
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 6
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.25
    temperature loop 1(2) : 104.88
    temperature loop 1(3) : 99.32
    temperature loop 3(1) : 19.36
    temperature loop 3(2) : 19.34
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.6
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00634721
    -----