    Log entry time 21:15:18 on June 9, 2008

    Entry number 241815

    keyword=End_of_Run_2102
    ****************************
     Run Number: 2102
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 3uA , BB_mag=700amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 353974       [+]: 174057       [-]: 174631       
    TIME     : [0]: 2.813 mins  [+]: 1.420 mins  [-]: 1.419 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.31744 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  30.05%      [+]:  31.91%      [-]:  31.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1367.7/136775.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/2487.3 Hz   T4[0] : 0.0/6835.3 Hz   T5[0] :1544.0/1544.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :1368.5/136852.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/2486.0 Hz   T4[+] : 0.0/6822.6 Hz   T5[+] :1544.5/1544.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :1368.8/136881.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/2490.9 Hz   T4[-] : 0.0/6853.7 Hz   T5[-] :1545.5/1545.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 230822/23082298  T2[0] :      0/0        T3[0] :      0/419752   T4[0] :      0/1153523  T5[0] : 260571/260571   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  17281/172811   
    T1[+] : 116608/11660893  T2[+] :      0/0        T3[+] :      0/211829   T4[+] :      0/581343   T5[+] : 131608/131608   T6[+] :      0/0        T7[+] :      0/0        T8[+] :   8725/87253    
    T1[-] : 116546/11654666  T2[-] :      0/0        T3[-] :      0/212084   T4[-] :      0/583552   T5[-] : 131590/131590   T6[-] :      0/0        T7[-] :      0/0        T8[-] :   8718/87188    
    
    AVERAGE CURRENT
    BCM x1 : 2.8414 uA  BCM x3 : 2.8464 uA  BCM x10: 1.4264 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -330.9 ppm     BCM u3 :     -249 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -393.2 ppm     BCM d3 :   -246.7 ppm     BCM d10:   -216.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0004803      BCM u3 [0]:0.0004807      BCM u10[0]:-3.142E-06     
    BCM u1 [+]:0.0002426      BCM u3 [+]:0.0002428      BCM u10[+]:-1.587E-06     
    BCM u1 [-]:0.0002425      BCM u3 [-]:0.0002428      BCM u10[-]:-1.585E-06     
    
    BCM d1 [0]:0.0004788      BCM d3 [0]:0.00048        BCM d10[0]:0.0004846      
    BCM d1 [+]:0.0002418      BCM d3 [+]:0.0002424      BCM d10[+]:0.0002448      
    BCM d1 [-]:0.0002418      BCM d3 [-]:0.0002424      BCM d10[-]:0.0002447      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2102 at Mon Jun 9 21:15:07 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00432344
    Right Arm arm angle : 0.197
    HALLA:p : 1192.17
    HALLA:dpp : -0.000181648
    Tiefenbach Hall A energy : 1192.17
    Left Arm Top VDC Current : 4.24805
    Left Arm Bottom VDC Current : -1.07422
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15803
    Left Arm Q2 power supply current : 299.545
    Left Arm Q2 momentum : 0.695645
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.265
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292903
    Left Arm Q3 gauss meter : 0.141331
    Left Arm Q3 power supply current : 276.918
    Left Arm Q3 momentum : 0.695567
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00330859
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.24e-05
    Right Arm Q2 power supply current : -0.000284699
    Right Arm Q2 momentum : -6.61526e-07
    Right Arm Q2 gauss meter : -0.0002867
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0271076
    Right Arm D1 momentum : 0.00431799
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 4.10994e-05
    Right Arm Q3 momentum : -1.59628e-07
    Right Arm Q3 gauss meter : -0.0002702
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 2.93622
    Current on Unser monitor : 14.241
    Current on Upstream bcm : 2.89091
    Current on Downstream bcm : 2.96972
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.1948
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.15
    Hall A momentum orbit correction (dpp) : -0.000194922
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.15
    Hall C energy (hallc_MeV) : 5710.97
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.825937
    IPM1H04A.XPOS : -1.16295
    IPM1H04A.YPOS : 1.28304
    IPM1H04B.XPOS : -1.80167
    IPM1H04B.YPOS : 1.9678
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.305664
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.334961
    -----
    Right Arm Collimator : -0.00883789
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 85
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.02112
    SLI vert. size mm : 0
    SLI y position : 2.72676
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 4.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.24
    temperature loop 1(2) : 104.89
    temperature loop 1(3) : 99.39
    temperature loop 3(1) : 19.65
    temperature loop 3(2) : 19.62
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.9
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00293052
    -----