     Run Number: 2104
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -100mV, 1.1uA , BB_mag=700amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 27371        [+]: 13534        [-]: 13428        
    TIME     : [0]: 0.413 mins  [+]: 0.237 mins  [-]: 0.237 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.09437 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  15.54%      [+]:  27.19%      [-]:  27.55%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :569.3/56935.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/1062.7 Hz   T4[0] : 0.0/3668.9 Hz   T5[0] :642.6/642.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :569.1/56912.7 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/1059.5 Hz   T4[+] : 0.0/3668.2 Hz   T5[+] :642.1/642.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :569.4/56941.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/1064.1 Hz   T4[-] : 0.0/3653.2 Hz   T5[-] :640.0/640.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14108/1410880  T2[0] :      0/0        T3[0] :      0/26333    T4[0] :      0/90917    T5[0] :  15923/15923    T6[0] :      0/0        T7[0] :      0/0        T8[0] :   2537/25375    
    T1[+] :   8093/809339   T2[+] :      0/0        T3[+] :      0/15067    T4[+] :      0/52165    T5[+] :   9131/9131     T6[+] :      0/0        T7[+] :      0/0        T8[+] :   1456/14562    
    T1[-] :   8085/808524   T2[-] :      0/0        T3[-] :      0/15110    T4[-] :      0/51873    T5[-] :   9087/9087     T6[-] :      0/0        T7[-] :      0/0        T8[-] :   1454/14540    
    
    AVERAGE CURRENT
    BCM x1 : 1.1606 uA  BCM x3 : 1.1655 uA  BCM x10: 0.5790 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     -294 ppm     BCM u3 :   -66.61 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -486.1 ppm     BCM d3 :   -132.2 ppm     BCM d10:   -79.41 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.882E-05      BCM u3 [0]:2.888E-05      BCM u10[0]:-4.612E-07     
    BCM u1 [+]:1.653E-05      BCM u3 [+]:1.657E-05      BCM u10[+]:-2.646E-07     
    BCM u1 [-]:1.651E-05      BCM u3 [-]:1.654E-05      BCM u10[-]:-2.644E-07     
    
    BCM d1 [0]:2.87E-05       BCM d3 [0]:2.888E-05      BCM d10[0]:2.916E-05      
    BCM d1 [+]:1.646E-05      BCM d3 [+]:1.657E-05      BCM d10[+]:1.672E-05      
    BCM d1 [-]:1.645E-05      BCM d3 [-]:1.655E-05      BCM d10[-]:1.67E-05       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2104 at Mon Jun 9 21:21:02 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00435396
    Right Arm arm angle : 0.197
    HALLA:p : 1192.18
    HALLA:dpp : -0.000170687
    Tiefenbach Hall A energy : 1192.18
    Left Arm Top VDC Current : 5.12695
    Left Arm Bottom VDC Current : 3.4668
    -----
    Left Arm Q1 momentum : 0.69547
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15797
    Left Arm Q2 power supply current : 299.546
    Left Arm Q2 momentum : 0.695648
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.268
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292903
    Left Arm Q3 gauss meter : 0.141335
    Left Arm Q3 power supply current : 276.92
    Left Arm Q3 momentum : 0.695571
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00391835
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.95e-05
    Right Arm Q2 power supply current : -7.02505e-05
    Right Arm Q2 momentum : -1.89008e-07
    Right Arm Q2 gauss meter : -0.0002843
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0261545
    Right Arm D1 momentum : 0.00435396
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 9.34076e-05
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11253
    -----
    Average current of the two cavities : 1.18886
    Current on Unser monitor : 13.8795
    Current on Upstream bcm : 1.16922
    Current on Downstream bcm : 1.2085
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 77.7314
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.18
    Hall A momentum orbit correction (dpp) : -0.000170547
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.19
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.691564
    IPM1H04A.XPOS : -1.15528
    IPM1H04A.YPOS : 1.18722
    IPM1H04B.XPOS : -1.78652
    IPM1H04B.YPOS : 1.83161
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.306152
    HacL_HPE1313A:0_Ch55 : 24.0234
    HacL_HPE1313A:0_Ch54 : -0.333984
    -----
    Right Arm Collimator : -0.00883789
    HacR_HPE1313A:0_Ch58 : -0.564453
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.840332
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.819876
    SLI vert. size mm : 0
    SLI y position : 0.458216
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 6
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.25
    temperature loop 1(2) : 104.9
    temperature loop 1(3) : 99.26
    temperature loop 3(1) : 19.4
    temperature loop 3(2) : 19.38
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.7
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068
    -----