Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:32:36 on June 9, 2008

    Entry number 241828

    keyword=End_of_Run_2107
    ****************************
     Run Number: 2107
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -150mV, 4uA , BB_mag=700amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 207088       [+]: 101944       [-]: 102047       
    TIME     : [0]: 2.673 mins  [+]: 1.350 mins  [-]: 1.349 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.18503 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  23.98%      [+]:  26.44%      [-]:  26.33%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :647.1/64710.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/2648.6 Hz   T4[0] : 0.0/7189.0 Hz   T5[0] :959.0/959.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :651.8/65179.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/2663.9 Hz   T4[+] : 0.0/7240.7 Hz   T5[+] :966.4/966.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :652.6/65264.3 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/2674.3 Hz   T4[-] : 0.0/7227.8 Hz   T5[-] :965.9/965.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 103770/10377010  T2[0] :      0/0        T3[0] :      0/424740   T4[0] :      0/1152830  T5[0] : 153785/153785   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  16421/164210   
    T1[+] :  52794/5279460  T2[+] :      0/0        T3[+] :      0/215776   T4[+] :      0/586488   T5[+] :  78280/78280    T6[+] :      0/0        T7[+] :      0/0        T8[+] :   8294/82943    
    T1[-] :  52835/5283539  T2[-] :      0/0        T3[-] :      0/216497   T4[-] :      0/585131   T5[-] :  78192/78192    T6[-] :      0/0        T7[-] :      0/0        T8[-] :   8289/82899    
    
    AVERAGE CURRENT
    BCM x1 : 3.0344 uA  BCM x3 : 3.0389 uA  BCM x10: 1.5235 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -440.9 ppm     BCM u3 :   -365.6 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -481.7 ppm     BCM d3 :   -365.2 ppm     BCM d10:   -330.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0004872      BCM u3 [0]:0.0004877      BCM u10[0]:-2.986E-06     
    BCM u1 [+]:0.0002479      BCM u3 [+]:0.0002482      BCM u10[+]:-1.508E-06     
    BCM u1 [-]:0.000248       BCM u3 [-]:0.0002482      BCM u10[-]:-1.507E-06     
    
    BCM d1 [0]:0.000486       BCM d3 [0]:0.000487       BCM d10[0]:0.0004916      
    BCM d1 [+]:0.0002473      BCM d3 [+]:0.0002478      BCM d10[+]:0.0002502      
    BCM d1 [-]:0.0002474      BCM d3 [-]:0.0002479      BCM d10[-]:0.0002502      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2107 at Mon Jun 9 21:32:26 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00433134
    Right Arm arm angle : 0.197
    HALLA:p : 1192.16
    HALLA:dpp : -0.000191614
    Tiefenbach Hall A energy : 1192.16
    Left Arm Top VDC Current : -2.29492
    Left Arm Bottom VDC Current : 0.732422
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.224
    Left Arm Q1 gauss meter : 0.04488
    Left Arm Q2 gauss meter : -0.15803
    Left Arm Q2 power supply current : 299.545
    Left Arm Q2 momentum : 0.695645
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.266
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141327
    Left Arm Q3 power supply current : 276.916
    Left Arm Q3 momentum : 0.695563
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00313892
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -7.92e-05
    Right Arm Q2 power supply current : -0.000162685
    Right Arm Q2 momentum : -3.78015e-07
    Right Arm Q2 gauss meter : -0.000297
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270617
    Right Arm D1 momentum : 0.0043278
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000283959
    Right Arm Q3 momentum : 0.000168477
    Right Arm Q3 gauss meter : -0.0002699
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 4.06229
    Current on Unser monitor : 16.0072
    Current on Upstream bcm : 4.00068
    Current on Downstream bcm : 4.1239
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 81.3667
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
    Hall A momentum orbit correction (dpp) : -0.000191749
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.16
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.80975
    IPM1H04A.XPOS : -1.15051
    IPM1H04A.YPOS : 1.25122
    IPM1H04B.XPOS : -1.79768
    IPM1H04B.YPOS : 1.9229
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.306152
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.334473
    -----
    Right Arm Collimator : -0.00888672
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.84082
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 91
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.81118
    SLI vert. size mm : 0
    SLI y position : 0.495775
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 4.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.24
    temperature loop 1(2) : 104.89
    temperature loop 1(3) : 99.11
    temperature loop 3(1) : 19.25
    temperature loop 3(2) : 19.23
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.5
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.000817917
    -----