    Log entry time 21:36:14 on June 9, 2008

    Entry number 241830

    keyword=End_of_Run_2108
    ****************************
     Run Number: 2108
     End of Run Comment:
    Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB TS thresh = -170mV, 4uA , BB_mag=700amps
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 202763       [+]: 100038       [-]: 99684        
    TIME     : [0]: 2.953 mins  [+]: 1.488 mins  [-]: 1.488 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.25933 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  17.92%      [+]:  20.04%      [-]:  19.87%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :577.8/57782.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/3061.2 Hz   T4[0] : 0.0/8122.6 Hz   T5[0] :721.4/721.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :579.6/57963.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/3075.1 Hz   T4[+] : 0.0/8156.5 Hz   T5[+] :726.6/726.6 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :579.4/57939.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/3062.4 Hz   T4[-] : 0.0/8119.1 Hz   T5[-] :718.8/718.8 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 102367/10236745  T2[0] :      0/0        T3[0] :      0/542325   T4[0] :      0/1438998  T5[0] : 127804/127804   T6[0] :      0/0        T7[0] :      0/0        T8[0] :  18141/181411   
    T1[+] :  51747/5174798  T2[+] :      0/0        T3[+] :      0/274541   T4[+] :      0/728189   T5[+] :  64870/64870    T6[+] :      0/0        T7[+] :      0/0        T8[+] :   9142/91420    
    T1[-] :  51731/5173117  T2[-] :      0/0        T3[-] :      0/273421   T4[-] :      0/724904   T5[-] :  64180/64180    T6[-] :      0/0        T7[-] :      0/0        T8[-] :   9142/91427    
    
    AVERAGE CURRENT
    BCM x1 : 3.5225 uA  BCM x3 : 3.5274 uA  BCM x10: 1.7700 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    205.4 ppm     BCM u3 :    295.3 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :      205 ppm     BCM d3 :    299.3 ppm     BCM d10:      320 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0006248      BCM u3 [0]:0.0006253      BCM u10[0]:-3.299E-06     
    BCM u1 [+]:0.0003159      BCM u3 [+]:0.0003162      BCM u10[+]:-1.663E-06     
    BCM u1 [-]:0.0003158      BCM u3 [-]:0.000316       BCM u10[-]:-1.662E-06     
    
    BCM d1 [0]:0.0006233      BCM d3 [0]:0.0006245      BCM d10[0]:0.0006304      
    BCM d1 [+]:0.0003151      BCM d3 [+]:0.0003158      BCM d10[+]:0.0003188      
    BCM d1 [-]:0.000315       BCM d3 [-]:0.0003156      BCM d10[-]:0.0003186      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2108 at Mon Jun 9 21:36:03 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.695494
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00433298
    Right Arm arm angle : 0.197
    HALLA:p : 1192.15
    HALLA:dpp : -0.000197467
    Tiefenbach Hall A energy : 1192.15
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 0.683594
    -----
    Left Arm Q1 momentum : 0.695399
    Left Arm Q1 power supply : 523.171
    Left Arm Q1 gauss meter : 0.04487
    Left Arm Q2 gauss meter : -0.15797
    Left Arm Q2 power supply current : 299.543
    Left Arm Q2 momentum : 0.695642
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 231.267
    Left Arm D1 momentum : 0.695494
    Left Arm D1 NMR : 0.292902
    Left Arm Q3 gauss meter : 0.141327
    Left Arm Q3 power supply current : 276.916
    Left Arm Q3 momentum : 0.695562
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00313892
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.18e-05
    Right Arm Q2 power supply current : -0.000107224
    Right Arm Q2 momentum : -2.49146e-07
    Right Arm Q2 gauss meter : -0.0002877
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0241176
    Right Arm D1 momentum : 0.00432072
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 1.12089e-05
    Right Arm Q3 momentum : 0.000166238
    Right Arm Q3 gauss meter : -0.0002703
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 11254
    -----
    Average current of the two cavities : 3.96847
    Current on Unser monitor : 16.9272
    Current on Upstream bcm : 3.93304
    Current on Downstream bcm : 4.00391
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.5695
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.14
    Hall A momentum orbit correction (dpp) : -0.000201012
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.14
    Hall C energy (hallc_MeV) : 5710.97
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.801046
    IPM1H04A.XPOS : -1.14027
    IPM1H04A.YPOS : 1.25819
    IPM1H04B.XPOS : -1.78655
    IPM1H04B.YPOS : 1.93036
    -----
    Left Arm Collimator : 0.871094
    HacL_HPE1313A:0_Ch58 : -0.306152
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.334473
    -----
    Right Arm Collimator : -0.00834961
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.839844
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -318.38
    Wien field : 8.9165
    Laser attenuation Hall A : 91
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.93789
    SLI vert. size mm : 0
    SLI y position : 0.923944
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 3
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.23
    temperature loop 1(2) : 104.88
    temperature loop 1(3) : 99.23
    temperature loop 3(1) : 19.36
    temperature loop 3(2) : 19.34
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.6
    Heat exchange LH2 : 19.6
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00293052
    -----