    Log entry time 16:45:33 on June 10, 2008

    Entry number 241853

    keyword=End_of_Run_2125
    ****************************
     Run Number: 2125
     End of Run Comment:
    Run_type=Cosmics,target_type=Holely Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=10   ps2=16777215   ps3=1   ps4=16777215   ps5=65535   ps6=65535   ps7=1   ps8=10   
    
    EVENTS   : [0]: 17817        [+]: 8793         [-]: 8766         
    TIME     : [0]: 11.868 mins  [+]: 5.880 mins  [-]: 5.880 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.79031 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  85.79%      [+]:  85.85%      [-]:  85.89%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.7/127.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :60.2/60.2 Hz   T4[0] : 0.0/1533.3 Hz   T5[0] : 0.0/12.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.8/0.8  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :12.7/127.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :60.3/60.3 Hz   T4[+] : 0.0/1534.4 Hz   T5[+] : 0.0/12.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.7/0.7  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :12.7/127.3 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :60.0/60.0 Hz   T4[-] : 0.0/1533.0 Hz   T5[-] : 0.0/12.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 1.0/1.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   9055/90557    T2[0] :      0/0        T3[0] :  42835/42835    T4[0] :      0/1091848  T5[0] :      0/8901     T6[0] :      0/0        T7[0] :    600/600      T8[0] :  72917/729173   
    T1[+] :   4482/44821    T2[+] :      0/0        T3[+] :  21280/21280    T4[+] :      0/541304   T5[+] :      0/4409     T6[+] :      0/0        T7[+] :    243/243      T8[+] :  36124/361245   
    T1[-] :   4490/44901    T2[-] :      0/0        T3[-] :  21163/21163    T4[-] :      0/540844   T5[-] :      0/4410     T6[-] :      0/0        T7[-] :    352/352      T8[-] :  36127/361273   
    
    AVERAGE CURRENT
    BCM x1 : -0.0041uA  BCM x3 : -0.0010uA  BCM x10: -0.0086uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-8.21E+04 ppm     BCM d10:-3.764E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-3.554E-06     BCM u3 [0]:-2.755E-06     BCM u10[0]:-1.327E-05     
    BCM u1 [+]:-1.909E-06     BCM u3 [+]:-1.417E-06     BCM u10[+]:-6.572E-06     
    BCM u1 [-]:-1.614E-06     BCM u3 [-]:-1.318E-06     BCM u10[-]:-6.574E-06     
    
    BCM d1 [0]:-2.344E-06     BCM d3 [0]:1.282E-06      BCM d10[0]:9.854E-07      
    BCM d1 [+]:-1.32E-06      BCM d3 [+]:5.787E-07      BCM d10[+]:4.65E-07       
    BCM d1 [-]:-1.003E-06     BCM d3 [-]:6.822E-07      BCM d10[-]:5.014E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2125 at Tue Jun 10 16:45:23 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00234696
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00432072
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 0.341797
    Left Arm Bottom VDC Current : -0.830078
    -----
    Left Arm Q1 momentum : 0.00014551
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003149
    Left Arm Q2 gauss meter : 0.0001118
    Left Arm Q2 power supply current : 0.00957663
    Left Arm Q2 momentum : 0.000219925
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36572
    Left Arm D1 momentum : 0.00234696
    Left Arm D1 NMR : 0.493104
    Left Arm Q3 gauss meter : 0.0015873
    Left Arm Q3 power supply current : -0.00612756
    Left Arm Q3 momentum : -1.66951e-05
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000800636
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -4.9e-06
    Right Arm Q2 power supply current : -0.000136804
    Right Arm Q2 momentum : -3.17876e-07
    Right Arm Q2 gauss meter : -0.0002796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0277007
    Right Arm D1 momentum : 0.00432072
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -2.24178e-05
    Right Arm Q3 momentum : 0.00016232
    Right Arm Q3 gauss meter : -0.0002713
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 12.156
    -----
    Average current of the two cavities : 0.0256895
    Current on Unser monitor : 11.4177
    Current on Upstream bcm : 0.0350416
    Current on Downstream bcm : 0.0163374
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.000830356
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.870996
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.338379
    -----
    Right Arm Collimator : -0.00883789
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.8027
    HacR_HPE1313A:0_Ch54 : -0.835938
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 3.18799
    Wien field : 0
    Laser attenuation Hall A : 93
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.819876
    SLI vert. size mm : 0
    SLI y position : 1.11174
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 204.5
    Heat exchange LH2 : 242.6
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00634721
    -----