Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:04:27 on June 10, 2008

    Entry number 241860

    keyword=End_of_Run_2128
    ****************************
     Run Number: 2128
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=10   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 2400         [+]: 1199         [-]: 1157         
    TIME     : [0]: 3.463 mins  [+]: 1.738 mins  [-]: 1.737 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.11384 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  89.87%      [+]:  89.92%      [-]:  90.26%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.6/116.1 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/10.1 Hz   T4[0] : 0.0/1332.6 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.9  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :11.7/116.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/10.3 Hz   T4[+] : 0.0/1337.2 Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/1.1  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :11.5/115.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/9.8  Hz   T4[-] : 0.0/1326.9 Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.6  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2411/24116    T2[0] :      0/0        T3[0] :      0/2103     T4[0] :      0/276857   T5[0] :      0/0        T6[0] :      0/0        T7[0] :      0/179      T8[0] :  21274/212740   
    T1[+] :   1219/12192    T2[+] :      0/0        T3[+] :      0/1077     T4[+] :      0/139464   T5[+] :      0/0        T6[+] :      0/0        T7[+] :      0/116      T8[+] :  10679/106797   
    T1[-] :   1202/12027    T2[-] :      0/0        T3[-] :      0/1024     T4[-] :      0/138316   T5[-] :      0/0        T6[-] :      0/0        T7[-] :      0/65       T8[-] :  10673/106739   
    
    AVERAGE CURRENT
    BCM x1 : -0.0042uA  BCM x3 : -0.0011uA  BCM x10: -0.0086uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-7.499E+04 ppm     BCM d10:-3.422E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.039E-06     BCM u3 [0]:-8.248E-07     BCM u10[0]:-3.87E-06      
    BCM u1 [+]:-5.625E-07     BCM u3 [+]:-4.292E-07     BCM u10[+]:-1.943E-06     
    BCM u1 [-]:-4.789E-07     BCM u3 [-]:-3.981E-07     BCM u10[-]:-1.94E-06      
    
    BCM d1 [0]:-7.09E-07      BCM d3 [0]:3.688E-07      BCM d10[0]:2.817E-07      
    BCM d1 [+]:-4.071E-07     BCM d3 [+]:1.715E-07      BCM d10[+]:1.383E-07      
    BCM d1 [-]:-3.078E-07     BCM d3 [-]:1.992E-07      BCM d10[-]:1.48E-07       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2128 at Tue Jun 10 17:04:17 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00237424
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00434797
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -1.75781
    Left Arm Bottom VDC Current : 3.51562
    -----
    Left Arm Q1 momentum : 0.000320749
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003295
    Left Arm Q2 gauss meter : 4.32e-05
    Left Arm Q2 power supply current : 0.00932954
    Left Arm Q2 momentum : 0.000478557
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36435
    Left Arm D1 momentum : 0.00237424
    Left Arm D1 NMR : 0.45268
    Left Arm Q3 gauss meter : 0.00156346
    Left Arm Q3 power supply current : -0.00616893
    Left Arm Q3 momentum : -1.57031e-05
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00187169
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 1.92e-05
    Right Arm Q2 power supply current : -0.000181172
    Right Arm Q2 momentum : -4.20971e-07
    Right Arm Q2 gauss meter : -0.0002828
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0257309
    Right Arm D1 momentum : 0.00435669
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -5.60446e-05
    Right Arm Q3 momentum : -1.40848e-07
    Right Arm Q3 gauss meter : -0.000271
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 12.149
    -----
    Average current of the two cavities : 0.02542
    Current on Unser monitor : 11.5611
    Current on Upstream bcm : 0.0346467
    Current on Downstream bcm : 0.0161933
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.28462e-05
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.870947
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.338867
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.8027
    HacR_HPE1313A:0_Ch54 : -0.836426
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 3.18799
    Wien field : 0
    Laser attenuation Hall A : 93
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.37888
    SLI vert. size mm : 0
    SLI y position : 0.51831
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 205.5
    Heat exchange LH2 : 243.7
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----