Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:12:07 on June 10, 2008

    Entry number 241862

    keyword=End_of_Run_2129
    ****************************
     Run Number: 2129
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=20   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=1   ps8=10   
    
    EVENTS   : [0]: 2267         [+]: 1126         [-]: 1109         
    TIME     : [0]: 6.166 mins  [+]: 3.072 mins  [-]: 3.071 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.53381 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  94.37%      [+]:  94.38%      [-]:  94.48%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 5.7/114.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/10.4 Hz   T4[0] : 0.0/1332.0 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.7/0.7  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] : 5.7/114.7 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/10.6 Hz   T4[+] : 0.0/1331.2 Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.6/0.6  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] : 5.7/114.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/10.2 Hz   T4[-] : 0.0/1333.3 Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.9/0.9  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2122/42442    T2[0] :      0/0        T3[0] :      0/3829     T4[0] :      0/492750   T5[0] :      0/0        T6[0] :      0/0        T7[0] :    277/277      T8[0] :  37881/378810   
    T1[+] :   1057/21145    T2[+] :      0/0        T3[+] :      0/1954     T4[+] :      0/245334   T5[+] :      0/0        T6[+] :      0/0        T7[+] :    115/115      T8[+] :  18871/188716   
    T1[-] :   1056/21133    T2[-] :      0/0        T3[-] :      0/1873     T4[-] :      0/245689   T5[-] :      0/0        T6[-] :      0/0        T7[-] :    158/158      T8[-] :  18869/188698   
    
    AVERAGE CURRENT
    BCM x1 : -0.0044uA  BCM x3 : -0.0011uA  BCM x10: -0.0086uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-6.93E+04 ppm     BCM d10:-2.908E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.929E-06     BCM u3 [0]:-1.5E-06       BCM u10[0]:-6.889E-06     
    BCM u1 [+]:-1.029E-06     BCM u3 [+]:-7.698E-07     BCM u10[+]:-3.432E-06     
    BCM u1 [-]:-9.003E-07     BCM u3 [-]:-7.181E-07     BCM u10[-]:-3.433E-06     
    
    BCM d1 [0]:-1.362E-06     BCM d3 [0]:6.692E-07      BCM d10[0]:5.036E-07      
    BCM d1 [+]:-7.695E-07     BCM d3 [+]:3.077E-07      BCM d10[+]:2.446E-07      
    BCM d1 [-]:-5.945E-07     BCM d3 [-]:3.535E-07      BCM d10[-]:2.593E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2129 at Tue Jun 10 17:11:57 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00241127
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00434034
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -1.70898
    Left Arm Bottom VDC Current : 4.44336
    -----
    Left Arm Q1 momentum : 0.000234694
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003215
    Left Arm Q2 gauss meter : 0.0001218
    Left Arm Q2 power supply current : 0.0103179
    Left Arm Q2 momentum : 0.000190895
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36313
    Left Arm D1 momentum : 0.00240654
    Left Arm D1 NMR : 0.235171
    Left Arm Q3 gauss meter : 0.00157774
    Left Arm Q3 power supply current : -0.00643224
    Left Arm Q3 momentum : -1.61566e-05
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000774125
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.4e-06
    Right Arm Q2 power supply current : -9.61322e-05
    Right Arm Q2 momentum : -5.4984e-07
    Right Arm Q2 gauss meter : -0.0002668
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0273406
    Right Arm D1 momentum : 0.00434034
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -0.000179343
    Right Arm Q3 momentum : 0.000160081
    Right Arm Q3 gauss meter : -0.0002714
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 12.176
    -----
    Average current of the two cavities : 0.0255834
    Current on Unser monitor : 11.7281
    Current on Upstream bcm : 0.0349547
    Current on Downstream bcm : 0.0162122
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.28462e-05
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.870947
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.337402
    -----
    Right Arm Collimator : -0.00810547
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.7051
    HacR_HPE1313A:0_Ch54 : -0.835449
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 3.18799
    Wien field : 0
    Laser attenuation Hall A : 93
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.07329
    SLI vert. size mm : 0
    SLI y position : 2.61408
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 205.8
    Heat exchange LH2 : 244.2
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----