    Log entry time 18:15:39 on June 10, 2008

    Entry number 241867

    keyword=End_of_Run_2133
    ****************************
     Run Number: 2133
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=22   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=1   ps8=10   
    
    EVENTS   : [0]: 1530         [+]: 728          [-]: 784          
    TIME     : [0]: 4.459 mins  [+]: 2.231 mins  [-]: 2.232 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.51786 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  94.75%      [+]:  95.00%      [-]:  94.63%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 4.2/93.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/9.8  Hz   T4[0] : 0.0/1336.3 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 2.2/2.2  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] : 4.3/94.1 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/9.9  Hz   T4[+] : 0.0/1329.1 Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 2.1/2.1  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] : 4.2/92.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/9.6  Hz   T4[-] : 0.0/1344.1 Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 2.4/2.4  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1133/24938    T2[0] :      0/0        T3[0] :      0/2611     T4[0] :      0/357516   T5[0] :      0/0        T6[0] :      0/0        T7[0] :    588/588      T8[0] :  27396/273967   
    T1[+] :    572/12602    T2[+] :      0/0        T3[+] :      0/1322     T4[+] :      0/177957   T5[+] :      0/0        T6[+] :      0/0        T7[+] :    279/279      T8[+] :  13710/137102   
    T1[-] :    565/12433    T2[-] :      0/0        T3[-] :      0/1282     T4[-] :      0/179959   T5[-] :      0/0        T6[-] :      0/0        T7[-] :    321/321      T8[-] :  13710/137104   
    
    AVERAGE CURRENT
    BCM x1 : -0.0043uA  BCM x3 : -0.0011uA  BCM x10: -0.0086uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-9.24E+04 ppm     BCM d10:-3.425E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.357E-06     BCM u3 [0]:-1.091E-06     BCM u10[0]:-4.986E-06     
    BCM u1 [+]:-7.35E-07      BCM u3 [+]:-5.646E-07     BCM u10[+]:-2.495E-06     
    BCM u1 [-]:-6.185E-07     BCM u3 [-]:-5.253E-07     BCM u10[-]:-2.495E-06     
    
    BCM d1 [0]:-9.544E-07     BCM d3 [0]:4.89E-07       BCM d10[0]:3.714E-07      
    BCM d1 [+]:-5.39E-07      BCM d3 [+]:2.226E-07      BCM d10[+]:1.797E-07      
    BCM d1 [-]:-4.019E-07     BCM d3 [-]:2.679E-07      BCM d10[-]:1.924E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2133 at Tue Jun 10 18:15:28 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00236645
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00439348
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 4.83398
    Left Arm Bottom VDC Current : -1.51367
    -----
    Left Arm Q1 momentum : 0.000117347
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003221
    Left Arm Q2 gauss meter : 7.65e-05
    Left Arm Q2 power supply current : 0.00898137
    Left Arm Q2 momentum : 0.000332087
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36454
    Left Arm D1 momentum : 0.00239707
    Left Arm D1 NMR : 0.209762
    Left Arm Q3 gauss meter : 0.00155066
    Left Arm Q3 power supply current : -0.00695886
    Left Arm Q3 momentum : -1.764e-05
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00136797
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 5.8e-06
    Right Arm Q2 power supply current : -0.000247725
    Right Arm Q2 momentum : -5.41249e-07
    Right Arm Q2 gauss meter : -0.0002769
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0271429
    Right Arm D1 momentum : 0.00438885
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000112089
    Right Arm Q3 momentum : 0.000158961
    Right Arm Q3 gauss meter : -0.0002716
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 12.14
    -----
    Average current of the two cavities : 0.0255328
    Current on Unser monitor : 12.6844
    Current on Upstream bcm : 0.0348515
    Current on Downstream bcm : 0.0162142
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.28462e-05
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.870947
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.338867
    -----
    Right Arm Collimator : -0.00898438
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.7539
    HacR_HPE1313A:0_Ch54 : -0.835938
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 3.18799
    Wien field : 0
    Laser attenuation Hall A : 93
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.81863
    SLI vert. size mm : 0
    SLI y position : 1.03662
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 208.8
    Heat exchange LH2 : 247.5
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----