Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:15:49 on June 10, 2008

    Entry number 241868

    keyword=Start_Run_2133,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
    Run Timestamp:       Tue Jun 10 18:10:47 EDT 2008
    Beginning-of-run EPICS data for Run Number 2133 at Tue Jun 10 18:15:18 EDT 2008
    
    
    
    Run_type=Cosmics
    target_type=Empty
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.6955
    leftarm_theta=53
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=35
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=22,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=1,ps8=10
    
    
    
    
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.000497551
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003394
    Left Arm Q2 power supply current : 0.009206
    Left Arm Q2 momentum : 0.000522982
    Left Arm Q2 gauss meter : 4.4e-05
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36375
    Left Arm D1 momentum : 0.0024121
    Left Arm D1 NMR : 0.382877
    Left Arm Q3 power supply current : -0.00730868
    Left Arm Q3 momentum : -1.8358e-05
    Left Arm Q3 gauss meter : 0.00157321
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.0008665
    -----
    Right Arm Q1 momentum : 0.00126193
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 3.8e-06
    Right Arm Q2 power supply current : -0.000188567
    Right Arm Q2 momentum : -3.09285e-07
    Right Arm Q2 gauss meter : -0.000265
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0276971
    Right Arm D1 momentum : 0.00437113
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -3.7363e-06
    Right Arm Q3 momentum : 0.000160081
    Right Arm Q3 gauss meter : -0.0002714
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0016039
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 12.191
    -----
    Left Arm Top VDC Current : -1.66016
    Left Arm Bottom VDC Current : 2.19727
    Left Arm Top VDC voltage : 4.00635
    Left Arm Bottom VDC voltage : 4.00293
    -----
    Right Arm Top VDC Current : -1.2207
    Right Arm Bottom VDC Current : -1.17188
    Right Arm Top VDC voltage : -0.0112305
    Right Arm Bottom VDC voltage : 0.000488281
    -----
    Average current of the two cavities : 0.0256267
    Current on Unser monitor : 12.3677
    Current on Upstream bcm : 0.0350196
    Current on Downstream bcm : 0.0162706
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.28462e-05
    Hall C Current :
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1
    -----
    Left Arm Collimator : 0.870947
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.338379
    Left Arm Angle Floor Angle : 53
    Left Arm Angle Vernier : 31.4
    Left Arm Scattering Angle : 53.002
    -----
    Right Arm Arm Collimator : -0.00888672
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.8027
    HacR_HPE1313A:0_Ch54 : -0.836426
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 93
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target :
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    Heat exchange loop 1 H2 : 208.8
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 247.5
    pressure loop He : 46.0982
    pressure loop H2 before : 53.8872
    pressure loop H2 return : 54.2107
    HPH He loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00634721
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.11056
    SLI vert. size mm : 0
    SLI y position : 3.72582
    -----
    FPP High Voltages and Currents at Tue Jun 10 18:15:28 EDT 2008
    MF7b1469_7gn0gen.F            1850.6
    MF7b1469_7gn0gen.E            0.5
    MF7b1469_7gn0ch0property.F    1850.6
    MF7b1469_7gn0ch0property.E    0.04
    MF7b1469_7gn0ch1property.F    1850.6
    MF7b1469_7gn0ch1property.E    0.07
    MF7b1469_7gn0ch2property.F    1850.6
    MF7b1469_7gn0ch2property.E    0.01
    MF7b1469_7gn0ch3property.F    1850.6
    MF7b1469_7gn0ch3property.E    0.04
    MF7b1469_7gn0ch4property.F    1850.6
    MF7b1469_7gn0ch4property.E    0.04
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.06
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.04
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.04
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.19
    MF7b1469_8gn0gen.F            1849.4
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1849.4
    MF7b1469_8gn0ch0property.E    -0.02
    MF7b1469_8gn0ch1property.F    1849.4
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    1849.4
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1849.4
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1849.4
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            1.4
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.01
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.02
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.02
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Tue Jun 10 18:15:30 EDT 2008
    HrsH_FPP_TH1                  3.89697
    HrsH_FPP_TH2                  4.02686
    HrsH_FPP_TH3                  6.96191
    HrsH_FPP_TH4                  7.06787
    
    FPP Wire Chambers Low Voltage at Tue Jun 10 18:15:30 EDT 2008
    HrsH_FPP_LV11P                4.92285
    HrsH_FPP_LV11M                -5.29199
    HrsH_FPP_LV12MA               -5.2666
    HrsH_FPP_LV12MB               -5.58496
    HrsH_FPP_LV21P                5.09375
    HrsH_FPP_LV21M                -4.53418
    HrsH_FPP_LV22MA               -4.71338
    HrsH_FPP_LV22MB               -4.7334
    HrsH_FPP_LV31P                4.81006
    HrsH_FPP_LV31M                -5.09717
    HrsH_FPP_LV32MA               -5.08545
    HrsH_FPP_LV32MB               -4.93066
    HrsH_FPP_LV42P                4.72559
    HrsH_FPP_LV42MA               -4.73047
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.64111
    HrsH_FPP_LV41MA               -4.80078
    HrsH_FPP_LV41MB               -4.6582
    
    FPP Level Shifters at Tue Jun 10 18:15:32 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.0708
    HacH_DTC_HPE1313A:0_Ch50      -5.11279
    
    FPP Gas Flow at Tue Jun 10 18:15:32 EDT 2008
    HrsH_GAS_rFPPc1               4.76411
    HrsH_GAS_rFPPc2               3.10931
    HrsH_GAS_rFPPc3               5.38934
    HrsH_GAS_rFPPc4               5.91723
    
    FPP Carbon Door Status at Tue Jun 10 18:15:32 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      disabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2311
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.8
    S2 Slot0 ch5 : -2166.5
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.9
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.9
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1818.5
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1798.4
    S1 Slot1 ch11 : -1707.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1544.3
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1797.3
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.1
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1587.9
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -24.4
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -981.2
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -811.2
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.1
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1513  -1720 
      2 :  -1633  -1533 
      3 :  -1496  -1686 
      4 :  -1877  -1861 
      5 :  -1567  -1640 
      6 :  -1662  -1660 
      7 :  -1476  -1343 
      8 :  -1546  -1675 
      9 :  -1349  -1800 
     10 :  -1803  -1470 
     11 :  -1702  -1252 
     12 :  -1281  -1250 
     13 :  -1820  -1250 
     14 :  -1343  -1251 
     15 :  -1587  -1810 
     16 :  -1612  -1520 
     17 :  -1336  -1740 
     18 :  -1646  -1468 
     19 :  -1742  -1799 
     20 :  -1575  -1778 
     21 :  -1793  -1625 
     22 :  -1717  -1862 
     23 :  -2032  -1626 
     24 :  -1558  -1284 
    # Map  BB_DE  Measured Current
      1 :   -154   -195 
      2 :   -176   -166 
      3 :   -157   -189 
      4 :   -199   -208 
      5 :   -164   -176 
      6 :   -183   -183 
      7 :   -161   -146 
      8 :   -164   -180 
      9 :   -146   -203 
     10 :   -191   -155 
     11 :   -180   -137 
     12 :   -140   -137 
     13 :   -200   -132 
     14 :   -144   -137 
     15 :   -170   -202 
     16 :   -173   -158 
     17 :   -140   -185 
     18 :   -187   -152 
     19 :   -193   -194 
     20 :   -178   -194 
     21 :   -190   -173 
     22 :   -196   -176 
     23 :   -225   -172 
     24 :   -169   -137 
    # Map  BB_E  Measured Voltage
      1 :  -1674  -1701 
      2 :  -1895  -1475 
      3 :  -1493  -1534 
      4 :  -1388  -1372 
      5 :  -1530  -1788 
      6 :  -1623  -1801 
      7 :  -1782  -1476 
      8 :  -1362  -1706 
      9 :  -1479  -1740 
     10 :  -1438  -1405 
     11 :  -1808  -1692 
     12 :  -1229  -1545 
     13 :  -1876  -1565 
     14 :  -1426  -1633 
     15 :  -1800  -1443 
     16 :  -1431  -1788 
     17 :  -1711  -1596 
     18 :  -1251  -1387 
     19 :  -1547  -1771 
     20 :  -1717  -1677 
     21 :  -1690  -1672 
     22 :  -1702  -1329 
     23 :  -1599  -1411 
     24 :  -1143     -4 
    # Map  BB_E  Measured Current
      1 :   -174   -182 
      2 :   -204   -158 
      3 :   -159   -166 
      4 :   -148   -153 
      5 :   -169   -187 
      6 :   -172   -199 
      7 :   -190   -161 
      8 :   -145   -186 
      9 :   -156   -182 
     10 :   -153   -148 
     11 :   -191   -178 
     12 :   -132   -163 
     13 :   -202   -162 
     14 :   -150   -165 
     15 :   -197   -149 
     16 :   -155   -168 
     17 :   -187   -177 
     18 :   -138   -138 
     19 :   -162   -187 
     20 :   -186   -180 
     21 :   -179   -172 
     22 :   -182   -138 
     23 :   -170   -144 
     24 :   -120     -0 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1352 
      2 :  -1326 
      3 :  -1350 
      4 :  -1159 
      5 :  -1369 
      6 :  -1381 
      7 :  -1456 
      8 :  -1295 
      9 :  -1376 
     10 :  -1464 
     11 :  -1502 
     12 :  -1353 
     13 :  -1486 
    # Map  BB_SC_R  Measured Current
      1 :   -509 
      2 :   -504 
      3 :   -510 
      4 :   -439 
      5 :   -517 
      6 :   -526 
      7 :   -552 
      8 :   -491 
      9 :   -523 
     10 :   -556 
     11 :   -568 
     12 :   -512 
     13 :   -563 
    # Map  BB_DC  Measured Voltage
      1 :     -0      1     -0      0 
      2 :     -0     -1     -0     -0 
      3 :     -0      0     -0     -0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0      0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :  -1015 
      2 :   -967 
      3 :   -972 
      4 :   -980 
      5 :   -986 
      6 :   -974 
      7 :   -953 
      8 :   -970 
      9 :  -1029 
     10 :  -1031 
     11 :   -968 
     12 :   -856 
     13 :   -990 
     14 :   -976 
     15 :   -939 
     16 :  -1054 
     17 :   -906 
     18 :   -928 
     19 :   -948 
     20 :   -931 
     21 :   -937 
     22 :   -914 
     23 :   -937 
     24 :   -800 
     25 :   -880 
     26 :   -975 
     27 :   -978 
    # Map  BB_PS_R  Measured Current
      1 :   -262 
      2 :   -249 
      3 :   -250 
      4 :   -250 
      5 :   -255 
      6 :   -246 
      7 :   -246 
      8 :   -247 
      9 :   -266 
     10 :   -261 
     11 :   -249 
     12 :   -218 
     13 :   -254 
     14 :   -249 
     15 :   -241 
     16 :   -270 
     17 :   -234 
     18 :   -237 
     19 :   -243 
     20 :   -239 
     21 :   -239 
     22 :   -234 
     23 :   -240 
     24 :   -205 
     25 :   -226 
     26 :   -249 
     27 :   -251 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1419 
      2 :  -1461 
      3 :  -1397 
      4 :  -1312 
      5 :  -1337 
      6 :  -1458 
      7 :  -1513 
      8 :  -1291 
      9 :  -1381 
     10 :  -1430 
     11 :  -1515 
     12 :  -1230 
     13 :  -1428 
    # Map  BB_SC_L  Measured Current
      1 :   -514 
      2 :   -486 
      3 :   -516 
      4 :   -459 
      5 :   -451 
      6 :   -525 
      7 :   -529 
      8 :   -464 
      9 :   -480 
     10 :   -519 
     11 :   -548 
     12 :   -475 
     13 :   -544 
    # Map  BB_CER  Measured Voltage
      1 :   2040   2341 
      2 :   2101   2361 
      3 :   1830   1622 
      4 :   1901   2161 
      5 :   1766   1900 
      6 :   2402   2039 
      7 :   1919   2250 
      8 :   1789   1920 
      9 :   1499   1453 
     10 :   2160   2159 
    # Map  BB_CER  Measured Current
      1 :    731    821 
      2 :    752    829 
      3 :    659    566 
      4 :    682    759 
      5 :    632    668 
      6 :    860    716 
      7 :    687    788 
      8 :    639    673 
      9 :    538    510 
     10 :    775    755 
    # Map  BB_PS_L  Measured Voltage
      1 :  -1029 
      2 :  -1017 
      3 :   -938 
      4 :  -1021 
      5 :   -988 
      6 :   -997 
      7 :   -985 
      8 :   -804 
      9 :   -999 
     10 :  -1028 
     11 :   -989 
     12 :   -996 
     13 :   -994 
     14 :   -986 
     15 :  -1019 
     16 :   -990 
     17 :   -999 
     18 :  -1050 
     19 :   -970 
     20 :   -864 
     21 :   -973 
     22 :   -972 
     23 :   -966 
     24 :   -991 
     25 :  -1032 
     26 :   -981 
     27 :  -1020 
    # Map  BB_PS_L  Measured Current
      1 :   -261 
      2 :   -263 
      3 :   -240 
      4 :   -263 
      5 :   -255 
      6 :   -255 
      7 :   -251 
      8 :   -207 
      9 :   -255 
     10 :   -265 
     11 :   -254 
     12 :   -258 
     13 :   -254 
     14 :   -252 
     15 :   -261 
     16 :   -255 
     17 :   -255 
     18 :   -272 
     19 :   -246 
     20 :   -222 
     21 :   -250 
     22 :   -252 
     23 :   -246 
     24 :   -254 
     25 :   -266 
     26 :   -252 
     27 :   -261 
    # Map  BB_SH  Measured Voltage
      1 :  -1513  -1633  -1496  -1877  -1822  -1979  -1519 
      2 :  -1567  -1662  -1476  -1690  -1529  -1439  -1744 
      3 :  -1546  -1349  -1803  -1702  -1675  -1786  -1723 
      4 :  -1281  -1820  -1343  -1824  -1360  -1895  -1757 
      5 :  -1587  -1612  -1336  -1646  -1454  -1583  -1706 
      6 :  -1742  -1575  -1793  -1852  -1915  -1628  -1468 
      7 :  -1717  -2032  -1558  -1720  -1860  -1630  -1577 
      8 :  -1533  -1686  -1861  -1269  -1824  -1936  -1641 
      9 :  -1640  -1660  -1343  -1675  -1677  -1479  -1712 
     10 :  -1800  -1470  -1252  -1346  -1470  -1467  -1719 
     11 :  -1250  -1250  -1251  -1810  -1406  -1633  -1353 
     12 :  -1520  -1740  -1468  -1669  -1597  -1756  -1758 
     13 :  -1799  -1778  -1625  -1862  -1397  -1755  -1791 
     14 :  -1626  -1284  -1674  -1519  -1727  -1530  -1765 
     15 :  -1895  -1493  -1388  -1530  -1747  -1700  -1680 
     16 :  -1623  -1782  -1362  -1831  -1593  -1768  -1393 
     17 :  -1479  -1438  -1808  -1229  -1630  -1624  -1752 
     18 :  -1876  -1426  -1800  -1189  -1871  -1612  -1544 
     19 :  -1431  -1711  -1251  -1547  -1315  -1843  -1330 
     20 :  -1717  -1690  -1702  -1470  -1542  -1571  -1683 
     21 :  -1599  -1143  -1701  -1475  -1807  -1402  -1420 
     22 :  -1534  -1372  -1788  -1583  -1800  -1745  -1634 
     23 :  -1801  -1476  -1706  -1740  -1841  -1357  -1519 
     24 :  -1405  -1692  -1545  -1684  -1473  -1692  -1346 
     25 :  -1565  -1633  -1443  -1788  -1526  -1500  -1736 
     26 :  -1596  -1387  -1771  -1473  -1452  -1750  -1628 
     27 :  -1677  -1672  -1329  -1411  -1450  -1633  -1637 
    # Map  BB_SH  Measured Current
      1 :   -154   -176   -157   -199   -194   -213   -162 
      2 :   -164   -183   -161   -177   -161   -152   -190 
      3 :   -164   -146   -191   -180   -179   -188   -182 
      4 :   -140   -200   -144   -194   -145   -188   -185 
      5 :   -170   -173   -140   -187   -138   -169   -170 
      6 :   -193   -178   -190   -193   -199   -167   -162 
      7 :   -196   -225   -169   -195   -195   -167   -166 
      8 :   -166   -189   -208   -137   -195   -214   -176 
      9 :   -176   -183   -146   -180   -182   -160   -181 
     10 :   -203   -155   -137   -147   -161   -153   -180 
     11 :   -137   -132   -137   -202   -155   -169   -148 
     12 :   -158   -185   -152   -176   -168   -186   -189 
     13 :   -194   -194   -173   -176   -145   -189   -185 
     14 :   -172   -137   -174   -161   -182   -167   -183 
     15 :   -204   -159   -148   -169   -187   -184   -179 
     16 :   -172   -190   -145   -198   -170   -185   -148 
     17 :   -156   -153   -191   -132   -169   -174   -188 
     18 :   -202   -150   -197   -130   -204   -180   -162 
     19 :   -155   -187   -138   -162   -142   -194   -141 
     20 :   -186   -179   -182   -163   -161   -164   -179 
     21 :   -170   -120   -182   -158   -194   -149   -151 
     22 :   -166   -153   -187   -168   -192   -186   -178 
     23 :   -199   -161   -186   -182   -194   -152   -158 
     24 :   -148   -178   -163   -185   -151   -183   -142 
     25 :   -162   -165   -149   -168   -160   -159   -186 
     26 :   -177   -138   -187   -158   -152   -193   -172 
     27 :   -180   -172   -138   -144   -149   -172   -180 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1677  -1672  -1329  -1411  -1450  -1633  -1637 
      2 :  -1596  -1387  -1771  -1473  -1452  -1750  -1628 
      3 :  -1565  -1633  -1443  -1788  -1526  -1500  -1736 
      4 :  -1405  -1692  -1545  -1684  -1473  -1692  -1346 
      5 :  -1801  -1476  -1706  -1740  -1841  -1357  -1519 
      6 :  -1534  -1372  -1788  -1583  -1800  -1745  -1634 
      7 :  -1599  -1143  -1701  -1475  -1807  -1402  -1420 
      8 :  -1717  -1690  -1702  -1470  -1542  -1571  -1683 
      9 :  -1431  -1711  -1251  -1547  -1315  -1843  -1330 
     10 :  -1876  -1426  -1800  -1189  -1871  -1612  -1544 
     11 :  -1479  -1438  -1808  -1229  -1630  -1624  -1752 
     12 :  -1623  -1782  -1362  -1831  -1593  -1768  -1393 
     13 :  -1895  -1493  -1388  -1530  -1747  -1700  -1680 
     14 :  -1626  -1284  -1674  -1519  -1727  -1530  -1765 
     15 :  -1799  -1778  -1625  -1862  -1397  -1755  -1791 
     16 :  -1520  -1740  -1468  -1669  -1597  -1756  -1758 
     17 :  -1250  -1250  -1251  -1810  -1406  -1633  -1353 
     18 :  -1800  -1470  -1252  -1346  -1470  -1467  -1719 
     19 :  -1640  -1660  -1343  -1675  -1677  -1479  -1712 
     20 :  -1533  -1686  -1861  -1269  -1824  -1936  -1641 
     21 :  -1717  -2032  -1558  -1720  -1860  -1630  -1577 
     22 :  -1742  -1575  -1793  -1852  -1915  -1628  -1468 
     23 :  -1587  -1612  -1336  -1646  -1454  -1583  -1706 
     24 :  -1281  -1820  -1343  -1824  -1360  -1895  -1757 
     25 :  -1546  -1349  -1803  -1702  -1675  -1786  -1723 
     26 :  -1567  -1662  -1476  -1690  -1529  -1439  -1744 
     27 :  -1513  -1633  -1496  -1877  -1822  -1979  -1519 
    # Map  BB_TESTMAP  Measured Current
      1 :   -180   -172   -138   -144   -149   -172   -180 
      2 :   -177   -138   -187   -158   -152   -193   -172 
      3 :   -162   -165   -149   -168   -160   -159   -186 
      4 :   -148   -178   -163   -185   -151   -183   -142 
      5 :   -199   -161   -186   -182   -194   -152   -158 
      6 :   -166   -153   -187   -168   -192   -186   -178 
      7 :   -170   -120   -182   -158   -194   -149   -151 
      8 :   -186   -179   -182   -163   -161   -164   -179 
      9 :   -155   -187   -138   -162   -142   -194   -141 
     10 :   -202   -150   -197   -130   -204   -180   -162 
     11 :   -156   -153   -191   -132   -169   -174   -188 
     12 :   -172   -190   -145   -198   -170   -185   -148 
     13 :   -204   -159   -148   -169   -187   -184   -179 
     14 :   -172   -137   -174   -161   -182   -167   -183 
     15 :   -194   -194   -173   -176   -145   -189   -185 
     16 :   -158   -185   -152   -176   -168   -186   -189 
     17 :   -137   -132   -137   -202   -155   -169   -148 
     18 :   -203   -155   -137   -147   -161   -153   -180 
     19 :   -176   -183   -146   -180   -182   -160   -181 
     20 :   -166   -189   -208   -137   -195   -214   -176 
     21 :   -196   -225   -169   -195   -195   -167   -166 
     22 :   -193   -178   -190   -193   -199   -167   -162 
     23 :   -170   -173   -140   -187   -138   -169   -170 
     24 :   -140   -200   -144   -194   -145   -188   -185 
     25 :   -164   -146   -191   -180   -179   -188   -182 
     26 :   -164   -183   -161   -177   -161   -152   -190 
     27 :   -154   -176   -157   -199   -194   -213   -162 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.200 V  (1659)