Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:29:09 on June 11, 2008

    Entry number 241897

    keyword=End_of_Run_2147
    ****************************
     Run Number: 2147
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=22   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=1   ps8=10   
    
    EVENTS   : [0]: 2570         [+]: 1262         [-]: 1266         
    TIME     : [0]: 1.673 mins  [+]: 0.858 mins  [-]: 0.859 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.29276 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.00%      [+]:  76.08%      [-]:  76.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/10.0 Hz   T4[0] : 0.0/1314.4 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] : 0.0/0.0  Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/10.2 Hz   T4[+] : 0.0/1313.3 Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] : 0.0/0.0  Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/9.8  Hz   T4[-] : 0.0/1311.3 Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T3[0] :      0/1006     T4[0] :      0/131927   T5[0] :      0/0        T6[0] :      0/0        T7[0] :      2/2        T8[0] :  10277/102779   
    T1[+] :      0/0        T2[+] :      0/0        T3[+] :      0/526      T4[+] :      0/67626    T5[+] :      0/0        T6[+] :      0/0        T7[+] :      2/2        T8[+] :   5273/52730    
    T1[-] :      0/0        T2[-] :      0/0        T3[-] :      0/506      T4[-] :      0/67560    T5[-] :      0/0        T6[-] :      0/0        T7[-] :      0/0        T8[-] :   5275/52757    
    
    AVERAGE CURRENT
    BCM x1 : -0.0047uA  BCM x3 : -0.0006uA  BCM x10: -0.0086uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-8.174E+04 ppm     BCM d10:-3.583E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-6.846E-07     BCM u3 [0]:-2.994E-07     BCM u10[0]:-1.863E-06     
    BCM u1 [+]:-3.872E-07     BCM u3 [+]:-1.597E-07     BCM u10[+]:-9.562E-07     
    BCM u1 [-]:-3.171E-07     BCM u3 [-]:-1.468E-07     BCM u10[-]:-9.56E-07      
    
    BCM d1 [0]:-2.53E-07      BCM d3 [0]:1.811E-07      BCM d10[0]:1.269E-07      
    BCM d1 [+]:-1.578E-07     BCM d3 [+]:8.39E-08       BCM d10[+]:6.286E-08      
    BCM d1 [-]:-1.056E-07     BCM d3 [-]:9.888E-08      BCM d10[-]:6.756E-08      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2147 at Wed Jun 11 17:29:03 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.00236589
    Left Arm arm angle : 53.002
    Right Arm D1 momentum : 0.00438067
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 1.70898
    Left Arm Bottom VDC Current : -0.488281
    -----
    Left Arm Q1 momentum : 0.00037864
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003398
    Left Arm Q2 gauss meter : 2.5e-05
    Left Arm Q2 power supply current : 0.00913861
    Left Arm Q2 momentum : 0.000468001
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36021
    Left Arm D1 momentum : 0.00234696
    Left Arm D1 NMR : 0.489685
    Left Arm Q3 gauss meter : 0.00076143
    Left Arm Q3 power supply current : -0.00632692
    Left Arm Q3 momentum : -1.5892e-05
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00194592
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 1.67e-05
    Right Arm Q2 power supply current : -0.000144198
    Right Arm Q2 momentum : -4.46745e-07
    Right Arm Q2 gauss meter : -0.0002726
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0266452
    Right Arm D1 momentum : 0.00438067
    Right Arm D1 NMR : 12.7779
    Right Arm Q3 power supply current : 2.24178e-05
    Right Arm Q3 momentum : -1.03288e-07
    Right Arm Q3 gauss meter : -0.0002743
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 0.0012167
    -----
    Average current of the two cavities : 0.0257416
    Current on Unser monitor : 12.4533
    Current on Upstream bcm : 0.0351483
    Current on Downstream bcm : 0.0163349
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00201263
    Hall C Current : 16.9012
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.870801
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.337402
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.565918
    HacR_HPE1313A:0_Ch55 : 22.8027
    HacR_HPE1313A:0_Ch54 : -1.02148
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 3.18799
    Wien field : 0
    Laser attenuation Hall A : 50
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.8559
    SLI vert. size mm : 0
    SLI y position : 2.6892
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 263.1
    Heat exchange LH2 : 289
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721
    -----