    keyword=Start_Run_2168,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB cosmics check -- long run 2
    Run Timestamp:       Fri Jun 13 00:53:49 EDT 2008
    Beginning-of-run EPICS data for Run Number 2168 at Fri Jun 13 00:54:04 EDT 2008
    
    
    
    Run_type=Cosmics
    target_type=Empty
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.6955
    leftarm_theta=53
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=35
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=BB cosmics check -- long run 2
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=16777215,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=1,ps8=10
    
    
    
    
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.000283197
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003253
    Left Arm Q2 power supply current : 0.00913861
    Left Arm Q2 momentum : 0.000223004
    Left Arm Q2 gauss meter : 0.0001222
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36021
    Left Arm D1 momentum : 0.00240681
    Left Arm D1 NMR : 0.208232
    Left Arm Q3 power supply current : -0.00632692
    Left Arm Q3 momentum : -1.5892e-05
    Left Arm Q3 gauss meter : 0.00078491
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.0008646
    -----
    Right Arm Q1 momentum : 0.000965005
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -1.8e-06
    Right Arm Q2 power supply current : -0.000151593
    Right Arm Q2 momentum : -3.52241e-07
    Right Arm Q2 gauss meter : -0.0002754
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0262886
    Right Arm D1 momentum : 0.00432126
    Right Arm D1 NMR : 12.7665
    Right Arm Q3 power supply current : -5.60446e-05
    Right Arm Q3 momentum : -1.40848e-07
    Right Arm Q3 gauss meter : -0.000275
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0015856
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 0.0012204
    -----
    Left Arm Top VDC Current : -0.927734
    Left Arm Bottom VDC Current : 0.488281
    Left Arm Top VDC voltage : 4.00146
    Left Arm Bottom VDC voltage : 3.99756
    -----
    Right Arm Top VDC Current : -1.17188
    Right Arm Bottom VDC Current : -1.12305
    Right Arm Top VDC voltage : -0.0112305
    Right Arm Bottom VDC voltage : 0.000976562
    -----
    Average current of the two cavities : 0.0256798
    Current on Unser monitor : 13.0398
    Current on Upstream bcm : 0.034995
    Current on Downstream bcm : 0.0163647
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.0024738
    Hall C Current : 16.61
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0.16528
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1
    -----
    Left Arm Collimator : 0.870801
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 24.0234
    HacL_HPE1313A:0_Ch54 : -0.338379
    Left Arm Angle Floor Angle : 53
    Left Arm Angle Vernier : 31.4
    Left Arm Scattering Angle : 53.002
    -----
    Right Arm Arm Collimator : -0.0081543
    HacR_HPE1313A:0_Ch58 : -0.554688
    HacR_HPE1313A:0_Ch55 : 22.8027
    HacR_HPE1313A:0_Ch54 : -0.98877
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 50
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    Heat exchange loop 1 H2 : 282.8
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 296.2
    pressure loop He : 46.0117
    pressure loop H2 before : 14.287
    pressure loop H2 return : 14.9722
    HPH He loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00634721
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.5118
    SLI vert. size mm : 0
    SLI y position : 0.525822
    -----
    FPP High Voltages and Currents at Fri Jun 13 00:54:10 EDT 2008
    MF7b1469_7gn0gen.F            1849.6
    MF7b1469_7gn0gen.E            0.5
    MF7b1469_7gn0ch0property.F    1849.6
    MF7b1469_7gn0ch0property.E    0.02
    MF7b1469_7gn0ch1property.F    1849.6
    MF7b1469_7gn0ch1property.E    0.04
    MF7b1469_7gn0ch2property.F    1849.6
    MF7b1469_7gn0ch2property.E    0.04
    MF7b1469_7gn0ch3property.F    1849.6
    MF7b1469_7gn0ch3property.E    0.04
    MF7b1469_7gn0ch4property.F    1849.6
    MF7b1469_7gn0ch4property.E    0.04
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.03
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.04
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.01
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.03
    MF7b1469_8gn0gen.F            1849.4
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1849.4
    MF7b1469_8gn0ch0property.E    -0.02
    MF7b1469_8gn0ch1property.F    1849.4
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    1849.4
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1849.4
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1849.4
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            0.7
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.01
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.01
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.02
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.03
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0.7
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    -0.01
    
    FPP Chamber Threshold voltages at Fri Jun 13 00:54:12 EDT 2008
    HrsH_FPP_TH1                  3.90137
    HrsH_FPP_TH2                  4.02002
    HrsH_FPP_TH3                  6.96387
    HrsH_FPP_TH4                  7.0752
    
    FPP Wire Chambers Low Voltage at Fri Jun 13 00:54:12 EDT 2008
    HrsH_FPP_LV11P                4.92529
    HrsH_FPP_LV11M                -5.2998
    HrsH_FPP_LV12MA               -5.26221
    HrsH_FPP_LV12MB               -5.58594
    HrsH_FPP_LV21P                5.19434
    HrsH_FPP_LV21M                -4.52588
    HrsH_FPP_LV22MA               -4.71094
    HrsH_FPP_LV22MB               -4.72705
    HrsH_FPP_LV31P                4.79932
    HrsH_FPP_LV31M                -5.09961
    HrsH_FPP_LV32MA               -5.08301
    HrsH_FPP_LV32MB               -4.92627
    HrsH_FPP_LV42P                4.71729
    HrsH_FPP_LV42MA               -4.72656
    HrsH_FPP_LV42MB               -4.59961
    HrsH_FPP_LV41P                4.64502
    HrsH_FPP_LV41MA               -4.79688
    HrsH_FPP_LV41MB               -4.65576
    
    FPP Level Shifters at Fri Jun 13 00:54:13 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.07275
    HacH_DTC_HPE1313A:0_Ch50      -4.81885
    
    FPP Gas Flow at Fri Jun 13 00:54:13 EDT 2008
    HrsH_GAS_rFPPc1               5.49698
    HrsH_GAS_rFPPc2               3.7467
    HrsH_GAS_rFPPc3               5.50259
    HrsH_GAS_rFPPc4               5.90132
    
    FPP Carbon Door Status at Fri Jun 13 00:54:13 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      disabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2310.3
    S2 Slot0 ch1 : -2211.5
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.1
    S2 Slot0 ch5 : -2165.8
    S2 Slot0 ch6 : -1940
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.2
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.9
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1818.5
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1798.4
    S1 Slot1 ch11 : -1707.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1543.5
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.9
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1587.9
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -24.4
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -859.7
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -981.2
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.9
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -992.2
    PRL1 Slot4 ch10 : -1031.7
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -756.5
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.1
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1297  -1470 
      2 :  -1349  -1435 
      3 :  -1291  -1459 
      4 :  -1641  -1566 
      5 :  -1342  -1289 
      6 :  -1488  -1465 
      7 :  -1277  -1206 
      8 :  -1311  -1429 
      9 :  -1157  -1592 
     10 :  -1583  -1254 
     11 :  -1538  -1542 
     12 :  -1315  -1564 
     13 :  -1633  -1559 
     14 :  -1197  -1536 
     15 :  -1403  -1556 
     16 :  -1356  -1320 
     17 :  -1139  -1580 
     18 :  -1442  -1269 
     19 :  -1390  -1454 
     20 :  -1362  -1575 
     21 :  -1459  -1503 
     22 :  -1494  -1694 
     23 :  -1560  -1472 
     24 :  -1514  -1273 
    # Map  BB_DE  Measured Current
      1 :   -134   -165 
      2 :   -143   -160 
      3 :   -138   -163 
      4 :   -174   -173 
      5 :   -142   -138 
      6 :   -163   -157 
      7 :   -137   -135 
      8 :   -144   -152 
      9 :   -125   -177 
     10 :   -169   -135 
     11 :   -158   -165 
     12 :   -148   -174 
     13 :   -178   -164 
     14 :   -128   -168 
     15 :   -150   -171 
     16 :   -149   -138 
     17 :   -120   -166 
     18 :   -161   -135 
     19 :   -153   -153 
     20 :   -154   -172 
     21 :   -159   -159 
     22 :   -167   -158 
     23 :   -173   -161 
     24 :   -163   -134 
    # Map  BB_E  Measured Voltage
      1 :  -1479  -1585 
      2 :  -1618  -1274 
      3 :  -1328  -1345 
      4 :  -1235  -1270 
      5 :  -1328  -1615 
      6 :  -1431  -1524 
      7 :  -1624  -1274 
      8 :  -1338  -1506 
      9 :  -1312  -1540 
     10 :  -1324  -1248 
     11 :  -1702  -1505 
     12 :  -1290  -1577 
     13 :  -1698  -1435 
     14 :  -1294  -1495 
     15 :  -1675  -1314 
     16 :  -1269  -1568 
     17 :  -1538  -1392 
     18 :  -1042  -1283 
     19 :  -1398  -1632 
     20 :  -1561  -1500 
     21 :  -1362  -1564 
     22 :  -1584  -1148 
     23 :  -1435  -1228 
     24 :  -1187     -4 
    # Map  BB_E  Measured Current
      1 :   -153   -168 
      2 :   -177   -134 
      3 :   -141   -147 
      4 :   -136   -138 
      5 :   -144   -174 
      6 :   -152   -167 
      7 :   -173   -139 
      8 :   -144   -164 
      9 :   -136   -163 
     10 :   -142   -132 
     11 :   -175   -156 
     12 :   -140   -167 
     13 :   -183   -146 
     14 :   -134   -158 
     15 :   -183   -132 
     16 :   -136   -149 
     17 :   -168   -151 
     18 :   -113   -134 
     19 :   -151   -170 
     20 :   -161   -164 
     21 :   -144   -159 
     22 :   -167   -118 
     23 :   -156   -132 
     24 :   -122      1 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1352 
      2 :  -1326 
      3 :  -1350 
      4 :  -1159 
      5 :  -1369 
      6 :  -1382 
      7 :  -1456 
      8 :  -1295 
      9 :  -1375 
     10 :  -1464 
     11 :  -1501 
     12 :  -1353 
     13 :  -1486 
    # Map  BB_SC_R  Measured Current
      1 :   -509 
      2 :   -503 
      3 :   -510 
      4 :   -441 
      5 :   -519 
      6 :   -523 
      7 :   -554 
      8 :   -492 
      9 :   -522 
     10 :   -555 
     11 :   -570 
     12 :   -514 
     13 :   -564 
    # Map  BB_DC  Measured Voltage
      1 :     -0     -0      0     -1 
      2 :      0     -0      1     -0 
      3 :     -0      1      0      0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :   -895 
      2 :   -858 
      3 :   -904 
      4 :   -913 
      5 :   -889 
      6 :   -878 
      7 :   -862 
      8 :  -1046 
      9 :   -966 
     10 :   -933 
     11 :   -924 
     12 :   -795 
     13 :   -909 
     14 :   -897 
     15 :   -867 
     16 :   -972 
     17 :   -797 
     18 :   -928 
     19 :   -802 
     20 :   -901 
     21 :   -802 
     22 :   -801 
     23 :   -811 
     24 :   -703 
     25 :   -765 
     26 :   -833 
     27 :   -852 
    # Map  BB_PS_R  Measured Current
      1 :   -231 
      2 :   -220 
      3 :   -231 
      4 :   -233 
      5 :   -228 
      6 :   -224 
      7 :   -223 
      8 :   -264 
      9 :   -248 
     10 :   -240 
     11 :   -236 
     12 :   -202 
     13 :   -231 
     14 :   -234 
     15 :   -221 
     16 :   -250 
     17 :   -201 
     18 :   -240 
     19 :   -205 
     20 :   -231 
     21 :   -205 
     22 :   -207 
     23 :   -208 
     24 :   -181 
     25 :   -197 
     26 :   -214 
     27 :   -218 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1418 
      2 :  -1461 
      3 :  -1397 
      4 :  -1311 
      5 :  -1337 
      6 :  -1458 
      7 :  -1513 
      8 :  -1290 
      9 :  -1381 
     10 :  -1430 
     11 :  -1514 
     12 :  -1230 
     13 :  -1428 
    # Map  BB_SC_L  Measured Current
      1 :   -513 
      2 :   -489 
      3 :   -516 
      4 :   -463 
      5 :   -449 
      6 :   -527 
      7 :   -527 
      8 :   -463 
      9 :   -479 
     10 :   -519 
     11 :   -549 
     12 :   -473 
     13 :   -544 
    # Map  BB_CER  Measured Voltage
      1 :      6      6 
      2 :      4      4 
      3 :      8      5 
      4 :      2      5 
      5 :      5      5 
      6 :      6      5 
      7 :      6      5 
      8 :      3      5 
      9 :      5      5 
     10 :      4      6 
    # Map  BB_CER  Measured Current
      1 :      2      1 
      2 :      2      2 
      3 :      2      1 
      4 :      2      3 
      5 :      1      2 
      6 :      2      1 
      7 :      2      3 
      8 :      2     -0 
      9 :      1      5 
     10 :      2     -0 
    # Map  BB_PS_L  Measured Voltage
      1 :   -868 
      2 :   -888 
      3 :   -807 
      4 :   -896 
      5 :   -880 
      6 :   -859 
      7 :   -860 
      8 :   -714 
      9 :   -885 
     10 :   -932 
     11 :   -880 
     12 :  -1013 
     13 :   -867 
     14 :   -876 
     15 :   -932 
     16 :   -891 
     17 :   -925 
     18 :   -976 
     19 :   -900 
     20 :   -795 
     21 :   -894 
     22 :   -880 
     23 :   -859 
     24 :  -1011 
     25 :   -949 
     26 :   -929 
     27 :   -921 
    # Map  BB_PS_L  Measured Current
      1 :   -224 
      2 :   -227 
      3 :   -207 
      4 :   -227 
      5 :   -229 
      6 :   -220 
      7 :   -221 
      8 :   -182 
      9 :   -226 
     10 :   -239 
     11 :   -226 
     12 :   -259 
     13 :   -222 
     14 :   -223 
     15 :   -239 
     16 :   -230 
     17 :   -237 
     18 :   -251 
     19 :   -230 
     20 :   -205 
     21 :   -229 
     22 :   -225 
     23 :   -220 
     24 :   -258 
     25 :   -242 
     26 :   -238 
     27 :   -236 
    # Map  BB_SH  Measured Voltage
      1 :  -1297  -1349  -1291  -1641  -1590  -1734  -1279 
      2 :  -1342  -1488  -1277  -1467  -1336  -1291  -1744 
      3 :  -1311  -1157  -1583  -1538  -1674  -1657  -1722 
      4 :  -1315  -1633  -1197  -1579  -1376  -1823  -1594 
      5 :  -1403  -1356  -1139  -1442  -1487  -1408  -1484 
      6 :  -1390  -1362  -1459  -1591  -1671  -1452  -1317 
      7 :  -1494  -1560  -1514  -1470  -1664  -1570  -1613 
      8 :  -1435  -1459  -1566  -1077  -1576  -1700  -1379 
      9 :  -1289  -1465  -1206  -1429  -1541  -1290  -1504 
     10 :  -1592  -1254  -1542  -1161  -1247  -1299  -1523 
     11 :  -1564  -1559  -1536  -1556  -1406  -1399  -1258 
     12 :  -1320  -1580  -1269  -1468  -1378  -1490  -1561 
     13 :  -1454  -1575  -1503  -1694  -1261  -1457  -1615 
     14 :  -1472  -1273  -1479  -1294  -1539  -1549  -1590 
     15 :  -1618  -1328  -1235  -1328  -1552  -1431  -1468 
     16 :  -1431  -1624  -1338  -1692  -1467  -1625  -1202 
     17 :  -1312  -1324  -1702  -1290  -1480  -1555  -1613 
     18 :  -1698  -1294  -1675  -1173  -1686  -1541  -1466 
     19 :  -1269  -1538  -1042  -1398  -1402  -1684  -1400 
     20 :  -1561  -1362  -1584  -1278  -1542  -1288  -1514 
     21 :  -1435  -1187  -1585  -1274  -1564  -1425  -1272 
     22 :  -1345  -1270  -1615  -1329  -1473  -1489  -1465 
     23 :  -1524  -1274  -1506  -1540  -1627  -1190  -1398 
     24 :  -1248  -1505  -1577  -1422  -1335  -1497  -1421 
     25 :  -1435  -1495  -1314  -1568  -1373  -1312  -1619 
     26 :  -1392  -1283  -1632  -1332  -1258  -1567  -1609 
     27 :  -1500  -1564  -1148  -1228  -1273  -1465  -1455 
    # Map  BB_SH  Measured Current
      1 :   -134   -143   -138   -174   -171   -187   -135 
      2 :   -142   -163   -137   -154   -140   -138   -190 
      3 :   -144   -125   -169   -158   -177   -176   -181 
      4 :   -148   -178   -128   -166   -146   -184   -164 
      5 :   -150   -149   -120   -161   -143   -148   -152 
      6 :   -153   -154   -159   -165   -175   -150   -145 
      7 :   -167   -173   -163   -165   -175   -160   -171 
      8 :   -160   -163   -173   -118   -165   -189   -142 
      9 :   -138   -157   -135   -152   -170   -140   -159 
     10 :   -177   -135   -165   -127   -135   -138   -160 
     11 :   -174   -164   -168   -171   -152   -146   -138 
     12 :   -138   -166   -135   -154   -146   -159   -165 
     13 :   -153   -172   -159   -158   -134   -155   -169 
     14 :   -161   -134   -153   -138   -159   -174   -169 
     15 :   -177   -141   -136   -144   -163   -158   -155 
     16 :   -152   -173   -144   -180   -154   -173   -128 
     17 :   -136   -142   -175   -140   -152   -166   -173 
     18 :   -183   -134   -183   -125   -183   -170   -156 
     19 :   -136   -168   -113   -151   -151   -175   -151 
     20 :   -161   -144   -167   -139   -163   -131   -163 
     21 :   -156   -122   -168   -134   -165   -153   -135 
     22 :   -147   -138   -174   -141   -157   -159   -158 
     23 :   -167   -139   -164   -163   -172   -131   -148 
     24 :   -132   -156   -167   -159   -140   -159   -154 
     25 :   -146   -158   -132   -149   -145   -140   -172 
     26 :   -151   -134   -170   -145   -134   -169   -170 
     27 :   -164   -159   -118   -132   -130   -159   -158 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1500  -1564  -1148  -1228  -1273  -1465  -1455 
      2 :  -1392  -1283  -1632  -1332  -1258  -1567  -1609 
      3 :  -1435  -1495  -1314  -1568  -1373  -1312  -1619 
      4 :  -1248  -1505  -1577  -1422  -1335  -1497  -1421 
      5 :  -1524  -1274  -1506  -1540  -1627  -1190  -1398 
      6 :  -1345  -1270  -1615  -1329  -1473  -1489  -1465 
      7 :  -1435  -1187  -1585  -1274  -1564  -1425  -1272 
      8 :  -1561  -1362  -1584  -1278  -1542  -1288  -1514 
      9 :  -1269  -1538  -1042  -1398  -1402  -1684  -1400 
     10 :  -1698  -1294  -1675  -1173  -1686  -1541  -1466 
     11 :  -1312  -1324  -1702  -1290  -1480  -1555  -1613 
     12 :  -1431  -1624  -1338  -1692  -1467  -1625  -1202 
     13 :  -1618  -1328  -1235  -1328  -1552  -1431  -1468 
     14 :  -1472  -1273  -1479  -1294  -1539  -1549  -1590 
     15 :  -1454  -1575  -1503  -1694  -1261  -1457  -1615 
     16 :  -1320  -1580  -1269  -1468  -1378  -1490  -1561 
     17 :  -1564  -1559  -1536  -1556  -1406  -1399  -1258 
     18 :  -1592  -1254  -1542  -1161  -1247  -1299  -1523 
     19 :  -1289  -1465  -1206  -1429  -1541  -1290  -1504 
     20 :  -1435  -1459  -1566  -1077  -1576  -1700  -1379 
     21 :  -1494  -1560  -1514  -1470  -1664  -1570  -1613 
     22 :  -1390  -1362  -1459  -1591  -1671  -1452  -1317 
     23 :  -1403  -1356  -1139  -1442  -1487  -1408  -1484 
     24 :  -1315  -1633  -1197  -1579  -1376  -1823  -1594 
     25 :  -1311  -1157  -1583  -1538  -1674  -1657  -1722 
     26 :  -1342  -1488  -1277  -1467  -1336  -1291  -1744 
     27 :  -1297  -1349  -1291  -1641  -1590  -1734  -1279 
    # Map  BB_TESTMAP  Measured Current
      1 :   -164   -159   -118   -132   -130   -159   -158 
      2 :   -151   -134   -170   -145   -134   -169   -170 
      3 :   -146   -158   -132   -149   -145   -140   -172 
      4 :   -132   -156   -167   -159   -140   -159   -154 
      5 :   -167   -139   -164   -163   -172   -131   -148 
      6 :   -147   -138   -174   -141   -157   -159   -158 
      7 :   -156   -122   -168   -134   -165   -153   -135 
      8 :   -161   -144   -167   -139   -163   -131   -163 
      9 :   -136   -168   -113   -151   -151   -175   -151 
     10 :   -183   -134   -183   -125   -183   -170   -156 
     11 :   -136   -142   -175   -140   -152   -166   -173 
     12 :   -152   -173   -144   -180   -154   -173   -128 
     13 :   -177   -141   -136   -144   -163   -158   -155 
     14 :   -161   -134   -153   -138   -159   -174   -169 
     15 :   -153   -172   -159   -158   -134   -155   -169 
     16 :   -138   -166   -135   -154   -146   -159   -165 
     17 :   -174   -164   -168   -171   -152   -146   -138 
     18 :   -177   -135   -165   -127   -135   -138   -160 
     19 :   -138   -157   -135   -152   -170   -140   -159 
     20 :   -160   -163   -173   -118   -165   -189   -142 
     21 :   -167   -173   -163   -165   -175   -160   -171 
     22 :   -153   -154   -159   -165   -175   -150   -145 
     23 :   -150   -149   -120   -161   -143   -148   -152 
     24 :   -148   -178   -128   -166   -146   -184   -164 
     25 :   -144   -125   -169   -158   -177   -176   -181 
     26 :   -142   -163   -137   -154   -140   -138   -190 
     27 :   -134   -143   -138   -174   -171   -187   -135 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.200 V  (1659)