Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:21:32 on June 13, 2008

    Entry number 241940

    keyword=Start_Run_2169,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB cosmics check -- HV: BB_08007_June13_2.set
    Run Timestamp:       Fri Jun 13 12:20:13 EDT 2008
    Beginning-of-run EPICS data for Run Number 2169 at Fri Jun 13 12:21:07 EDT 2008
    
    
    
    Run_type=Cosmics
    target_type=Empty
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.6955
    leftarm_theta=53
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=35
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=BB cosmics check -- HV: BB_08007_June13_2.set
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=16777215,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=1,ps8=10
    
    
    
    
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.000362993
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003375
    Left Arm Q2 power supply current : 0.00913861
    Left Arm Q2 momentum : 0.000357598
    Left Arm Q2 gauss meter : 7.07e-05
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36021
    Left Arm D1 momentum : 0.00237536
    Left Arm D1 NMR : 0.158146
    Left Arm Q3 power supply current : -0.00632692
    Left Arm Q3 momentum : -1.5892e-05
    Left Arm Q3 gauss meter : 0.00079625
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.0008533
    -----
    Right Arm Q1 momentum : 0.00239661
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 1.67e-05
    Right Arm Q2 power supply current : -0.000240331
    Right Arm Q2 momentum : -5.58431e-07
    Right Arm Q2 gauss meter : -0.0002744
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270264
    Right Arm D1 momentum : 0.0043774
    Right Arm D1 NMR : 12.7679
    Right Arm Q3 power supply current : -5.60446e-05
    Right Arm Q3 momentum : -1.40848e-07
    Right Arm Q3 gauss meter : -0.0002756
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0016062
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 0.0012196
    -----
    Left Arm Top VDC Current : 5.32227
    Left Arm Bottom VDC Current : -0.146484
    Left Arm Top VDC voltage : 4.01123
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -1.17188
    Right Arm Bottom VDC Current : -1.12305
    Right Arm Top VDC voltage : -0.0117188
    Right Arm Bottom VDC voltage : 0.000488281
    -----
    Average current of the two cavities : 0.0256898
    Current on Unser monitor : 11.872
    Current on Upstream bcm : 0.0351829
    Current on Downstream bcm : 0.0161966
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00171184
    Hall C Current : 17.0882
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0.165359
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 297794
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1
    -----
    Left Arm Collimator : 0.870801
    HacL_HPE1313A:0_Ch58 : -0.30127
    HacL_HPE1313A:0_Ch55 : 24.1211
    HacL_HPE1313A:0_Ch54 : -0.338867
    Left Arm Angle Floor Angle : 53
    Left Arm Angle Vernier : 31.4
    Left Arm Scattering Angle : 53.002
    -----
    Right Arm Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.554199
    HacR_HPE1313A:0_Ch55 : 22.9004
    HacR_HPE1313A:0_Ch54 : -0.986816
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 50
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    Heat exchange loop 1 H2 : 283
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 296.2
    pressure loop He : 46.0316
    pressure loop H2 before : 14.1863
    pressure loop H2 return : 14.9386
    HPH He loop 1 : 0.0669839
    HPH H2 loop 3 : 0.011068
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.35652
    SLI vert. size mm : 0
    SLI y position : 1.44225
    -----
    FPP High Voltages and Currents at Fri Jun 13 12:21:13 EDT 2008
    MF7b1469_7gn0gen.F            1849.6
    MF7b1469_7gn0gen.E            0.5
    MF7b1469_7gn0ch0property.F    1849.6
    MF7b1469_7gn0ch0property.E    0.02
    MF7b1469_7gn0ch1property.F    1849.6
    MF7b1469_7gn0ch1property.E    0.07
    MF7b1469_7gn0ch2property.F    1849.6
    MF7b1469_7gn0ch2property.E    0.01
    MF7b1469_7gn0ch3property.F    1849.6
    MF7b1469_7gn0ch3property.E    0.04
    MF7b1469_7gn0ch4property.F    1849.6
    MF7b1469_7gn0ch4property.E    0.04
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.03
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.04
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.01
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.03
    MF7b1469_8gn0gen.F            1849.4
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1849.4
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    1849.4
    MF7b1469_8gn0ch1property.E    0.02
    MF7b1469_8gn0ch2property.F    1849.4
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1849.4
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1849.4
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            0.7
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.01
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.02
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Fri Jun 13 12:21:15 EDT 2008
    HrsH_FPP_TH1                  3.8999
    HrsH_FPP_TH2                  4.02588
    HrsH_FPP_TH3                  6.9624
    HrsH_FPP_TH4                  7.05762
    
    FPP Wire Chambers Low Voltage at Fri Jun 13 12:21:16 EDT 2008
    HrsH_FPP_LV11P                4.92432
    HrsH_FPP_LV11M                -5.2832
    HrsH_FPP_LV12MA               -5.27881
    HrsH_FPP_LV12MB               -5.58545
    HrsH_FPP_LV21P                5.19336
    HrsH_FPP_LV21M                -4.52783
    HrsH_FPP_LV22MA               -4.71289
    HrsH_FPP_LV22MB               -4.71924
    HrsH_FPP_LV31P                4.81348
    HrsH_FPP_LV31M                -5.09961
    HrsH_FPP_LV32MA               -5.08643
    HrsH_FPP_LV32MB               -4.94336
    HrsH_FPP_LV42P                4.70654
    HrsH_FPP_LV42MA               -4.72363
    HrsH_FPP_LV42MB               -4.59277
    HrsH_FPP_LV41P                4.62549
    HrsH_FPP_LV41MA               -4.8042
    HrsH_FPP_LV41MB               -4.66064
    
    FPP Level Shifters at Fri Jun 13 12:21:16 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.07129
    HacH_DTC_HPE1313A:0_Ch50      -4.81885
    
    FPP Gas Flow at Fri Jun 13 12:21:17 EDT 2008
    HrsH_GAS_rFPPc1               5.4586
    HrsH_GAS_rFPPc2               3.26842
    HrsH_GAS_rFPPc3               5.50821
    HrsH_GAS_rFPPc4               5.90506
    
    FPP Carbon Door Status at Fri Jun 13 12:21:17 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      disabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2310.3
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.1
    S2 Slot0 ch5 : -2165.8
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1877.7
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.2
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.9
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1818.5
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1798.4
    S1 Slot1 ch11 : -1707.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1544.3
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.9
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1588.6
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -24.4
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -785.2
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -980.5
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.9
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -835.2
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1339  -1502 
      2 :  -1313  -1427 
      3 :  -1288  -1482 
      4 :  -1645  -1573 
      5 :  -1380  -1273 
      6 :  -1491  -1455 
      7 :  -1287  -1197 
      8 :  -1350  -1462 
      9 :  -1185  -1585 
     10 :  -1602  -1293 
     11 :  -1532  -1538 
     12 :  -1319  -1550 
     13 :  -1623  -1559 
     14 :  -1216  -1538 
     15 :  -1427  -1578 
     16 :  -1411  -1321 
     17 :  -1132  -1573 
     18 :  -1453  -1285 
     19 :  -1381  -1404 
     20 :  -1395  -1590 
     21 :  -1459  -1495 
     22 :  -1519  -1681 
     23 :  -1584  -1465 
     24 :  -1504  -1270 
    # Map  BB_DE  Measured Current
      1 :   -137   -167 
      2 :   -142   -158 
      3 :   -136   -162 
      4 :   -174   -181 
      5 :   -146   -137 
      6 :   -165   -158 
      7 :   -141   -131 
      8 :   -146   -160 
      9 :   -124   -175 
     10 :   -170   -138 
     11 :   -160   -167 
     12 :   -146   -174 
     13 :   -172   -166 
     14 :   -135   -169 
     15 :   -154   -171 
     16 :   -152   -139 
     17 :   -121   -162 
     18 :   -159   -140 
     19 :   -154   -148 
     20 :   -156   -172 
     21 :   -157   -155 
     22 :   -172   -158 
     23 :   -175   -156 
     24 :   -165   -134 
    # Map  BB_E  Measured Voltage
      1 :  -1517  -1569 
      2 :  -1623  -1293 
      3 :  -1314  -1381 
      4 :  -1235  -1265 
      5 :  -1355  -1608 
      6 :  -1446  -1546 
      7 :  -1607  -1303 
      8 :  -1340  -1503 
      9 :  -1340  -1541 
     10 :  -1304  -1255 
     11 :  -1690  -1530 
     12 :  -1286  -1572 
     13 :  -1735  -1432 
     14 :  -1272  -1473 
     15 :  -1652  -1296 
     16 :  -1286  -1578 
     17 :  -1523  -1413 
     18 :  -1058  -1289 
     19 :  -1392  -1632 
     20 :  -1541  -1500 
     21 :  -1332  -1578 
     22 :  -1574  -1173 
     23 :  -1432  -1240 
     24 :  -1192     -4 
    # Map  BB_E  Measured Current
      1 :   -160   -166 
      2 :   -178   -138 
      3 :   -139   -152 
      4 :   -135   -138 
      5 :   -147   -172 
      6 :   -154   -169 
      7 :   -172   -142 
      8 :   -141   -165 
      9 :   -140   -161 
     10 :   -138   -130 
     11 :   -180   -161 
     12 :   -135   -168 
     13 :   -190   -146 
     14 :   -131   -156 
     15 :   -182   -134 
     16 :   -138   -149 
     17 :   -166   -155 
     18 :   -118   -129 
     19 :   -148   -168 
     20 :   -165   -164 
     21 :   -142   -161 
     22 :   -166   -124 
     23 :   -152   -130 
     24 :   -122     -1 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1352 
      2 :  -1326 
      3 :  -1350 
      4 :  -1159 
      5 :  -1369 
      6 :  -1382 
      7 :  -1456 
      8 :  -1295 
      9 :  -1375 
     10 :  -1464 
     11 :  -1501 
     12 :  -1353 
     13 :  -1486 
    # Map  BB_SC_R  Measured Current
      1 :   -512 
      2 :   -503 
      3 :   -511 
      4 :   -437 
      5 :   -518 
      6 :   -524 
      7 :   -553 
      8 :   -488 
      9 :   -523 
     10 :   -555 
     11 :   -570 
     12 :   -510 
     13 :   -564 
    # Map  BB_DC  Measured Voltage
      1 :     -0     -0     -0     -0 
      2 :      0     -0     -0     -0 
      3 :     -0      0     -0     -0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :   -883 
      2 :   -842 
      3 :   -845 
      4 :   -853 
      5 :   -857 
      6 :   -848 
      7 :   -829 
      8 :   -843 
      9 :   -895 
     10 :   -897 
     11 :   -842 
     12 :   -856 
     13 :   -860 
     14 :   -849 
     15 :   -817 
     16 :   -917 
     17 :   -787 
     18 :   -807 
     19 :   -824 
     20 :   -810 
     21 :   -815 
     22 :   -796 
     23 :   -815 
     24 :   -800 
     25 :   -765 
     26 :   -848 
     27 :   -853 
    # Map  BB_PS_R  Measured Current
      1 :   -226 
      2 :   -216 
      3 :   -213 
      4 :   -220 
      5 :   -218 
      6 :   -218 
      7 :   -212 
      8 :   -218 
      9 :   -229 
     10 :   -228 
     11 :   -214 
     12 :   -220 
     13 :   -223 
     14 :   -217 
     15 :   -207 
     16 :   -234 
     17 :   -202 
     18 :   -207 
     19 :   -211 
     20 :   -207 
     21 :   -208 
     22 :   -205 
     23 :   -209 
     24 :   -204 
     25 :   -197 
     26 :   -218 
     27 :   -218 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1419 
      2 :  -1461 
      3 :  -1397 
      4 :  -1311 
      5 :  -1337 
      6 :  -1458 
      7 :  -1513 
      8 :  -1290 
      9 :  -1380 
     10 :  -1430 
     11 :  -1514 
     12 :  -1230 
     13 :  -1428 
    # Map  BB_SC_L  Measured Current
      1 :   -513 
      2 :   -485 
      3 :   -520 
      4 :   -463 
      5 :   -450 
      6 :   -523 
      7 :   -527 
      8 :   -464 
      9 :   -479 
     10 :   -518 
     11 :   -551 
     12 :   -466 
     13 :   -542 
    # Map  BB_CER  Measured Voltage
      1 :      8      6 
      2 :      3      4 
      3 :      7      5 
      4 :      3      5 
      5 :      6      5 
      6 :      4      5 
      7 :      7      5 
      8 :      2      5 
      9 :      6      5 
     10 :      4      6 
    # Map  BB_CER  Measured Current
      1 :      2     -1 
      2 :      2      4 
      3 :      2      1 
      4 :      2      3 
      5 :      2      3 
      6 :      1      1 
      7 :      2      2 
      8 :      2      2 
      9 :      2      3 
     10 :      1      1 
    # Map  BB_PS_L  Measured Voltage
      1 :   -895 
      2 :   -885 
      3 :   -816 
      4 :   -888 
      5 :   -859 
      6 :   -867 
      7 :   -857 
      8 :   -804 
      9 :   -869 
     10 :   -894 
     11 :   -860 
     12 :   -866 
     13 :   -864 
     14 :   -858 
     15 :   -885 
     16 :   -861 
     17 :   -869 
     18 :   -914 
     19 :   -844 
     20 :   -865 
     21 :   -847 
     22 :   -845 
     23 :   -841 
     24 :   -862 
     25 :   -898 
     26 :   -854 
     27 :   -887 
    # Map  BB_PS_L  Measured Current
      1 :   -226 
      2 :   -228 
      3 :   -209 
      4 :   -228 
      5 :   -220 
      6 :   -222 
      7 :   -219 
      8 :   -205 
      9 :   -222 
     10 :   -229 
     11 :   -222 
     12 :   -223 
     13 :   -221 
     14 :   -221 
     15 :   -223 
     16 :   -222 
     17 :   -221 
     18 :   -236 
     19 :   -217 
     20 :   -220 
     21 :   -218 
     22 :   -217 
     23 :   -214 
     24 :   -221 
     25 :   -230 
     26 :   -218 
     27 :   -225 
    # Map  BB_SH  Measured Voltage
      1 :  -1339  -1313  -1288  -1645  -1621  -1739  -1323 
      2 :  -1380  -1491  -1287  -1459  -1336  -1309  -1531 
      3 :  -1350  -1185  -1602  -1532  -1474  -1559  -1470 
      4 :  -1319  -1623  -1216  -1630  -1377  -1819  -1583 
      5 :  -1427  -1411  -1132  -1453  -1497  -1424  -1493 
      6 :  -1381  -1395  -1459  -1634  -1703  -1452  -1330 
      7 :  -1519  -1584  -1504  -1502  -1664  -1565  -1626 
      8 :  -1427  -1482  -1573  -1090  -1578  -1700  -1389 
      9 :  -1273  -1455  -1197  -1462  -1525  -1280  -1499 
     10 :  -1585  -1293  -1538  -1190  -1282  -1300  -1516 
     11 :  -1550  -1559  -1538  -1578  -1409  -1425  -1252 
     12 :  -1321  -1573  -1285  -1462  -1400  -1547  -1595 
     13 :  -1404  -1590  -1495  -1681  -1250  -1452  -1611 
     14 :  -1465  -1270  -1517  -1304  -1539  -1563  -1581 
     15 :  -1623  -1314  -1235  -1355  -1553  -1431  -1479 
     16 :  -1446  -1607  -1340  -1685  -1468  -1606  -1227 
     17 :  -1340  -1304  -1690  -1286  -1467  -1537  -1591 
     18 :  -1735  -1272  -1652  -1173  -1680  -1522  -1455 
     19 :  -1286  -1523  -1058  -1392  -1430  -1687  -1387 
     20 :  -1541  -1332  -1574  -1289  -1538  -1317  -1507 
     21 :  -1432  -1192  -1569  -1293  -1601  -1425  -1266 
     22 :  -1381  -1265  -1608  -1359  -1452  -1530  -1456 
     23 :  -1546  -1303  -1503  -1541  -1658  -1190  -1388 
     24 :  -1255  -1530  -1572  -1456  -1326  -1497  -1421 
     25 :  -1432  -1473  -1296  -1578  -1365  -1289  -1616 
     26 :  -1413  -1289  -1632  -1325  -1272  -1589  -1604 
     27 :  -1500  -1578  -1173  -1240  -1296  -1465  -1468 
    # Map  BB_SH  Measured Current
      1 :   -137   -142   -136   -174   -172   -187   -136 
      2 :   -146   -165   -141   -155   -140   -141   -166 
      3 :   -146   -124   -170   -160   -156   -167   -153 
      4 :   -146   -172   -135   -170   -148   -180   -167 
      5 :   -154   -152   -121   -159   -142   -151   -152 
      6 :   -154   -156   -157   -167   -178   -148   -139 
      7 :   -172   -175   -165   -167   -175   -159   -175 
      8 :   -158   -162   -181   -119   -162   -191   -147 
      9 :   -137   -158   -131   -160   -165   -138   -159 
     10 :   -175   -138   -167   -131   -138   -137   -161 
     11 :   -174   -166   -169   -171   -153   -151   -137 
     12 :   -139   -162   -140   -154   -149   -163   -170 
     13 :   -148   -172   -155   -158   -128   -153   -169 
     14 :   -156   -134   -160   -137   -163   -171   -168 
     15 :   -178   -139   -135   -147   -161   -161   -155 
     16 :   -154   -172   -141   -182   -153   -168   -130 
     17 :   -140   -138   -180   -135   -149   -165   -173 
     18 :   -190   -131   -182   -124   -185   -164   -156 
     19 :   -138   -166   -118   -148   -151   -180   -145 
     20 :   -165   -142   -166   -141   -163   -140   -156 
     21 :   -152   -122   -166   -138   -174   -151   -134 
     22 :   -152   -138   -172   -146   -156   -161   -158 
     23 :   -169   -142   -165   -161   -176   -130   -146 
     24 :   -130   -161   -168   -159   -143   -156   -153 
     25 :   -146   -156   -134   -149   -143   -137   -172 
     26 :   -155   -129   -168   -144   -136   -170   -173 
     27 :   -164   -161   -124   -130   -131   -157   -158 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1500  -1578  -1173  -1240  -1296  -1465  -1468 
      2 :  -1413  -1289  -1632  -1325  -1272  -1589  -1604 
      3 :  -1432  -1473  -1296  -1578  -1365  -1289  -1616 
      4 :  -1255  -1530  -1572  -1456  -1326  -1497  -1421 
      5 :  -1546  -1303  -1503  -1541  -1658  -1190  -1388 
      6 :  -1381  -1265  -1608  -1359  -1452  -1530  -1456 
      7 :  -1432  -1192  -1569  -1293  -1601  -1425  -1266 
      8 :  -1541  -1332  -1574  -1289  -1538  -1317  -1507 
      9 :  -1286  -1523  -1058  -1392  -1430  -1687  -1387 
     10 :  -1735  -1272  -1652  -1173  -1680  -1522  -1455 
     11 :  -1340  -1304  -1690  -1286  -1467  -1537  -1591 
     12 :  -1446  -1607  -1340  -1685  -1468  -1606  -1227 
     13 :  -1623  -1314  -1235  -1355  -1553  -1431  -1479 
     14 :  -1465  -1270  -1517  -1304  -1539  -1563  -1581 
     15 :  -1404  -1590  -1495  -1681  -1250  -1452  -1611 
     16 :  -1321  -1573  -1285  -1462  -1400  -1547  -1595 
     17 :  -1550  -1559  -1538  -1578  -1409  -1425  -1252 
     18 :  -1585  -1293  -1538  -1190  -1282  -1300  -1516 
     19 :  -1273  -1455  -1197  -1462  -1525  -1280  -1499 
     20 :  -1427  -1482  -1573  -1090  -1578  -1700  -1389 
     21 :  -1519  -1584  -1504  -1502  -1664  -1565  -1626 
     22 :  -1381  -1395  -1459  -1634  -1703  -1452  -1330 
     23 :  -1427  -1411  -1132  -1453  -1497  -1424  -1493 
     24 :  -1319  -1623  -1216  -1630  -1377  -1819  -1583 
     25 :  -1350  -1185  -1602  -1532  -1474  -1559  -1470 
     26 :  -1380  -1491  -1287  -1459  -1336  -1309  -1531 
     27 :  -1339  -1313  -1288  -1645  -1621  -1739  -1323 
    # Map  BB_TESTMAP  Measured Current
      1 :   -164   -161   -124   -130   -131   -157   -158 
      2 :   -155   -129   -168   -144   -136   -170   -173 
      3 :   -146   -156   -134   -149   -143   -137   -172 
      4 :   -130   -161   -168   -160   -139   -159   -152 
      5 :   -169   -142   -165   -161   -176   -130   -149 
      6 :   -152   -138   -172   -142   -156   -165   -159 
      7 :   -152   -122   -166   -138   -174   -151   -135 
      8 :   -165   -142   -166   -141   -163   -140   -156 
      9 :   -138   -166   -118   -148   -151   -180   -145 
     10 :   -190   -131   -182   -124   -185   -164   -156 
     11 :   -140   -138   -180   -135   -149   -165   -173 
     12 :   -154   -172   -141   -182   -153   -168   -130 
     13 :   -178   -139   -135   -147   -161   -161   -155 
     14 :   -156   -134   -160   -137   -163   -171   -168 
     15 :   -148   -172   -155   -158   -128   -153   -169 
     16 :   -139   -162   -140   -154   -149   -163   -170 
     17 :   -174   -166   -169   -171   -153   -151   -137 
     18 :   -175   -138   -167   -131   -138   -137   -161 
     19 :   -137   -158   -131   -160   -165   -138   -159 
     20 :   -158   -162   -181   -119   -162   -191   -147 
     21 :   -172   -175   -165   -167   -175   -159   -175 
     22 :   -154   -156   -157   -167   -178   -148   -139 
     23 :   -154   -152   -121   -159   -142   -151   -152 
     24 :   -146   -172   -135   -170   -148   -180   -167 
     25 :   -146   -124   -170   -160   -156   -167   -153 
     26 :   -146   -165   -141   -155   -140   -141   -166 
     27 :   -137   -142   -136   -174   -172   -187   -136 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.200 V  (1659)