    User name a-onl

    Log entry time 17:10:26 on June 14, 2008

    Entry number 241944

    keyword=Start_Run_2171,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB cosmics check -- HV: BB_08007_June14_1.set
    Run Timestamp:       Sat Jun 14 17:09:41 EDT 2008
    Beginning-of-run EPICS data for Run Number 2171 at Sat Jun 14 17:09:52 EDT 2008
    
    
    
    Run_type=Cosmics
    target_type=Empty
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.6955
    leftarm_theta=53
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=35
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=BB cosmics check -- HV: BB_08007_June14_1.set
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=16777215,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=1,ps8=10
    
    
    
    
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.000323878
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003358
    Left Arm Q2 power supply current : 0.00913861
    Left Arm Q2 momentum : 0.000136354
    Left Arm Q2 gauss meter : 9.24e-05
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36021
    Left Arm D1 momentum : 0.00240598
    Left Arm D1 NMR : 0.156939
    Left Arm Q3 power supply current : -0.00632692
    Left Arm Q3 momentum : -1.5892e-05
    Left Arm Q3 gauss meter : 0.00078619
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.000855
    -----
    Right Arm Q1 momentum : 0.00144751
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 1.93e-05
    Right Arm Q2 power supply current : -0.000240331
    Right Arm Q2 momentum : -5.24066e-07
    Right Arm Q2 gauss meter : -0.0002661
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0274077
    Right Arm D1 momentum : 0.00434552
    Right Arm D1 NMR : 12.7646
    Right Arm Q3 power supply current : 6.35172e-05
    Right Arm Q3 momentum : 0.000133774
    Right Arm Q3 gauss meter : -0.0002763
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.001599
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : 0.0012201
    -----
    Left Arm Top VDC Current : -0.683594
    Left Arm Bottom VDC Current : 2.83203
    Left Arm Top VDC voltage : 4.00781
    Left Arm Bottom VDC voltage : 4.00146
    -----
    Right Arm Top VDC Current : -1.12305
    Right Arm Bottom VDC Current : -1.17188
    Right Arm Top VDC voltage : -0.0112305
    Right Arm Bottom VDC voltage : 0.000976562
    -----
    Average current of the two cavities : 0.0259098
    Current on Unser monitor : 11.9815
    Current on Upstream bcm : 0.0356217
    Current on Downstream bcm : 0.0161978
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00140787
    Hall C Current : -0.206164
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0.163311
    MBSY1c magnet current (amp) : MBSY1C --- Invalid channel name
    MBSY1c Bdl : MBSY1C.BDL --- Invalid channel name
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1
    -----
    Left Arm Collimator : 0.870801
    HacL_HPE1313A:0_Ch58 : -0.30127
    HacL_HPE1313A:0_Ch55 : 24.2188
    HacL_HPE1313A:0_Ch54 : -0.337891
    Left Arm Angle Floor Angle : 53
    Left Arm Angle Vernier : 31.4
    Left Arm Scattering Angle : 53.002
    -----
    Right Arm Arm Collimator : -0.00878906
    HacR_HPE1313A:0_Ch58 : -0.554199
    HacR_HPE1313A:0_Ch55 : 22.998
    HacR_HPE1313A:0_Ch54 : -0.982422
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 50
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    Heat exchange loop 1 H2 : 283.1
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 296.2
    pressure loop He : 46.1181
    pressure loop H2 before : 13.8903
    pressure loop H2 return : 14.6197
    HPH He loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00293052
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.92298
    SLI vert. size mm : 0
    SLI y position : 1.90047
    -----
    FPP High Voltages and Currents at Sat Jun 14 17:10:08 EDT 2008
    MF7b1469_7gn0gen.F            1849.6
    MF7b1469_7gn0gen.E            0.5
    MF7b1469_7gn0ch0property.F    1849.6
    MF7b1469_7gn0ch0property.E    0.02
    MF7b1469_7gn0ch1property.F    1849.6
    MF7b1469_7gn0ch1property.E    0.04
    MF7b1469_7gn0ch2property.F    1849.6
    MF7b1469_7gn0ch2property.E    0.01
    MF7b1469_7gn0ch3property.F    1849.6
    MF7b1469_7gn0ch3property.E    0.04
    MF7b1469_7gn0ch4property.F    1849.6
    MF7b1469_7gn0ch4property.E    0.01
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.03
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.02
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.01
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.05
    MF7b1469_8gn0gen.F            1849.4
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1849.4
    MF7b1469_8gn0ch0property.E    -0.02
    MF7b1469_8gn0ch1property.F    1849.4
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    1849.4
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1849.4
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1849.4
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            1.4
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.01
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.02
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Sat Jun 14 17:10:10 EDT 2008
    HrsH_FPP_TH1                  3.89502
    HrsH_FPP_TH2                  4.02539
    HrsH_FPP_TH3                  6.96338
    HrsH_FPP_TH4                  7.06738
    
    FPP Wire Chambers Low Voltage at Sat Jun 14 17:10:10 EDT 2008
    HrsH_FPP_LV11P                4.92529
    HrsH_FPP_LV11M                -5.2998
    HrsH_FPP_LV12MA               -5.26221
    HrsH_FPP_LV12MB               -5.58496
    HrsH_FPP_LV21P                5.19824
    HrsH_FPP_LV21M                -4.52344
    HrsH_FPP_LV22MA               -4.70996
    HrsH_FPP_LV22MB               -4.71777
    HrsH_FPP_LV31P                4.81689
    HrsH_FPP_LV31M                -5.10205
    HrsH_FPP_LV32MA               -5.08252
    HrsH_FPP_LV32MB               -4.93506
    HrsH_FPP_LV42P                4.71729
    HrsH_FPP_LV42MA               -4.72754
    HrsH_FPP_LV42MB               -4.60645
    HrsH_FPP_LV41P                4.61768
    HrsH_FPP_LV41MA               -4.80322
    HrsH_FPP_LV41MB               -4.65967
    
    FPP Level Shifters at Sat Jun 14 17:10:11 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.07178
    HacH_DTC_HPE1313A:0_Ch50      -4.81592
    
    FPP Gas Flow at Sat Jun 14 17:10:11 EDT 2008
    HrsH_GAS_rFPPc1               5.03367
    HrsH_GAS_rFPPc2               2.96142
    HrsH_GAS_rFPPc3               5.46983
    HrsH_GAS_rFPPc4               5.90787
    
    FPP Carbon Door Status at Sat Jun 14 17:10:11 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      disabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2310.3
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.8
    S2 Slot0 ch5 : -2166.5
    S2 Slot0 ch6 : -1940
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.9
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.9
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1818.5
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1798.4
    S1 Slot1 ch11 : -1707.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1544.3
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.9
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1587.9
    GCER Slot2 ch10 : -15.7
    GCER Slot2 ch11 : -23.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -980.5
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.1
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1339  -1503 
      2 :  -1336  -1418 
      3 :  -1244  -1475 
      4 :  -1588  -1593 
      5 :  -1410  -1273 
      6 :  -1482  -1444 
      7 :  -1285  -1196 
      8 :  -1345  -1452 
      9 :  -1193  -1595 
     10 :  -1607  -1296 
     11 :  -1536  -1539 
     12 :  -1330  -1554 
     13 :  -1626  -1560 
     14 :  -1217  -1544 
     15 :  -1436  -1589 
     16 :  -1405  -1324 
     17 :  -1139  -1585 
     18 :  -1466  -1288 
     19 :  -1381  -1417 
     20 :  -1397  -1599 
     21 :  -1471  -1500 
     22 :  -1531  -1681 
     23 :  -1583  -1460 
     24 :  -1509  -1270 
    # Map  BB_DE  Measured Current
      1 :   -138   -169 
      2 :   -142   -156 
      3 :   -131   -165 
      4 :   -168   -179 
      5 :   -148   -135 
      6 :   -163   -158 
      7 :   -140   -129 
      8 :   -143   -158 
      9 :   -130   -178 
     10 :   -170   -137 
     11 :   -162   -165 
     12 :   -146   -172 
     13 :   -176   -167 
     14 :   -134   -165 
     15 :   -152   -176 
     16 :   -152   -138 
     17 :   -122   -170 
     18 :   -162   -133 
     19 :   -155   -151 
     20 :   -156   -174 
     21 :   -157   -158 
     22 :   -176   -156 
     23 :   -172   -157 
     24 :   -163   -133 
    # Map  BB_E  Measured Voltage
      1 :  -1523  -1578 
      2 :  -1622  -1299 
      3 :  -1317  -1384 
      4 :  -1235  -1271 
      5 :  -1361  -1608 
      6 :  -1437  -1548 
      7 :  -1602  -1311 
      8 :  -1346  -1510 
      9 :  -1340  -1545 
     10 :  -1300  -1265 
     11 :  -1681  -1537 
     12 :  -1287  -1585 
     13 :  -1676  -1419 
     14 :  -1289  -1459 
     15 :  -1641  -1291 
     16 :  -1311  -1588 
     17 :  -1532  -1430 
     18 :  -1066  -1291 
     19 :  -1379  -1648 
     20 :  -1558  -1500 
     21 :  -1332  -1585 
     22 :  -1578  -1176 
     23 :  -1419  -1252 
     24 :  -1197     -4 
    # Map  BB_E  Measured Current
      1 :   -162   -168 
      2 :   -178   -138 
      3 :   -137   -153 
      4 :   -136   -137 
      5 :   -145   -175 
      6 :   -156   -166 
      7 :   -169   -144 
      8 :   -144   -164 
      9 :   -143   -162 
     10 :   -140   -135 
     11 :   -176   -163 
     12 :   -135   -168 
     13 :   -181   -143 
     14 :   -134   -152 
     15 :   -180   -134 
     16 :   -142   -150 
     17 :   -168   -156 
     18 :   -115   -130 
     19 :   -144   -174 
     20 :   -165   -164 
     21 :   -140   -161 
     22 :   -168   -120 
     23 :   -150   -130 
     24 :   -126     -0 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1352 
      2 :  -1326 
      3 :  -1350 
      4 :  -1159 
      5 :  -1369 
      6 :  -1382 
      7 :  -1456 
      8 :  -1295 
      9 :  -1375 
     10 :  -1464 
     11 :  -1501 
     12 :  -1353 
     13 :  -1486 
    # Map  BB_SC_R  Measured Current
      1 :   -512 
      2 :   -503 
      3 :   -510 
      4 :   -439 
      5 :   -520 
      6 :   -526 
      7 :   -552 
      8 :   -493 
      9 :   -520 
     10 :   -556 
     11 :   -568 
     12 :   -515 
     13 :   -562 
    # Map  BB_DC  Measured Voltage
      1 :     -1      0      0     -0 
      2 :      0     -1     -0     -0 
      3 :     -0      1      1     -0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :   -868 
      2 :   -835 
      3 :   -846 
      4 :   -846 
      5 :   -866 
      6 :   -855 
      7 :   -846 
      8 :   -846 
      9 :   -911 
     10 :   -914 
     11 :   -875 
     12 :   -865 
     13 :   -877 
     14 :   -881 
     15 :   -846 
     16 :   -917 
     17 :   -842 
     18 :   -849 
     19 :   -870 
     20 :   -851 
     21 :   -834 
     22 :   -835 
     23 :   -843 
     24 :   -840 
     25 :   -797 
     26 :   -852 
     27 :   -870 
    # Map  BB_PS_R  Measured Current
      1 :   -225 
      2 :   -210 
      3 :   -219 
      4 :   -216 
      5 :   -224 
      6 :   -215 
      7 :   -217 
      8 :   -216 
      9 :   -233 
     10 :   -236 
     11 :   -224 
     12 :   -219 
     13 :   -224 
     14 :   -226 
     15 :   -218 
     16 :   -234 
     17 :   -215 
     18 :   -218 
     19 :   -222 
     20 :   -218 
     21 :   -214 
     22 :   -214 
     23 :   -216 
     24 :   -216 
     25 :   -206 
     26 :   -215 
     27 :   -226 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1418 
      2 :  -1462 
      3 :  -1397 
      4 :  -1311 
      5 :  -1337 
      6 :  -1458 
      7 :  -1512 
      8 :  -1290 
      9 :  -1380 
     10 :  -1430 
     11 :  -1515 
     12 :  -1230 
     13 :  -1428 
    # Map  BB_SC_L  Measured Current
      1 :   -514 
      2 :   -486 
      3 :   -517 
      4 :   -460 
      5 :   -448 
      6 :   -525 
      7 :   -528 
      8 :   -460 
      9 :   -479 
     10 :   -518 
     11 :   -552 
     12 :   -473 
     13 :   -542 
    # Map  BB_CER  Measured Voltage
      1 :      7      6 
      2 :      4      4 
      3 :      7      5 
      4 :      3      5 
      5 :      6      5 
      6 :      6      5 
      7 :      5      5 
      8 :      3      5 
      9 :      5      5 
     10 :      4      6 
    # Map  BB_CER  Measured Current
      1 :      3      1 
      2 :      2      4 
      3 :      3     -1 
      4 :      2      3 
      5 :      2      3 
      6 :      1      1 
      7 :      2      2 
      8 :      2      2 
      9 :      2      3 
     10 :      1      1 
    # Map  BB_PS_L  Measured Voltage
      1 :   -927 
      2 :   -915 
      3 :   -862 
      4 :   -940 
      5 :   -903 
      6 :   -914 
      7 :   -906 
      8 :   -867 
      9 :   -930 
     10 :   -954 
     11 :   -932 
     12 :   -944 
     13 :   -934 
     14 :   -929 
     15 :   -967 
     16 :   -940 
     17 :   -875 
     18 :   -894 
     19 :   -837 
     20 :   -858 
     21 :   -833 
     22 :   -822 
     23 :   -842 
     24 :   -860 
     25 :   -846 
     26 :   -833 
     27 :   -838 
    # Map  BB_PS_L  Measured Current
      1 :   -238 
      2 :   -232 
      3 :   -222 
      4 :   -240 
      5 :   -232 
      6 :   -235 
      7 :   -231 
      8 :   -222 
      9 :   -238 
     10 :   -244 
     11 :   -239 
     12 :   -242 
     13 :   -240 
     14 :   -238 
     15 :   -247 
     16 :   -242 
     17 :   -224 
     18 :   -228 
     19 :   -216 
     20 :   -221 
     21 :   -212 
     22 :   -210 
     23 :   -216 
     24 :   -220 
     25 :   -217 
     26 :   -212 
     27 :   -215 
    # Map  BB_SH  Measured Voltage
      1 :  -1339  -1336  -1244  -1588  -1634  -1763  -1325 
      2 :  -1410  -1482  -1285  -1473  -1385  -1324  -1589 
      3 :  -1345  -1193  -1607  -1536  -1529  -1556  -1524 
      4 :  -1330  -1626  -1217  -1624  -1376  -1842  -1593 
      5 :  -1436  -1405  -1139  -1466  -1502  -1425  -1493 
      6 :  -1381  -1397  -1471  -1632  -1697  -1452  -1334 
      7 :  -1531  -1583  -1509  -1503  -1656  -1570  -1632 
      8 :  -1418  -1475  -1593  -1088  -1586  -1700  -1386 
      9 :  -1273  -1444  -1196  -1452  -1524  -1280  -1495 
     10 :  -1595  -1296  -1539  -1196  -1276  -1302  -1520 
     11 :  -1554  -1560  -1544  -1589  -1409  -1426  -1256 
     12 :  -1324  -1585  -1288  -1476  -1404  -1556  -1617 
     13 :  -1417  -1599  -1500  -1681  -1250  -1460  -1614 
     14 :  -1460  -1270  -1523  -1304  -1545  -1555  -1577 
     15 :  -1622  -1317  -1235  -1361  -1534  -1441  -1470 
     16 :  -1437  -1602  -1346  -1669  -1471  -1604  -1228 
     17 :  -1340  -1300  -1681  -1287  -1465  -1537  -1593 
     18 :  -1676  -1289  -1641  -1175  -1672  -1534  -1450 
     19 :  -1311  -1532  -1066  -1379  -1430  -1687  -1389 
     20 :  -1558  -1332  -1578  -1302  -1542  -1324  -1507 
     21 :  -1419  -1197  -1578  -1299  -1594  -1426  -1270 
     22 :  -1384  -1271  -1608  -1364  -1454  -1534  -1454 
     23 :  -1548  -1311  -1510  -1545  -1662  -1192  -1386 
     24 :  -1265  -1537  -1585  -1464  -1332  -1504  -1418 
     25 :  -1419  -1459  -1291  -1588  -1368  -1293  -1628 
     26 :  -1430  -1291  -1648  -1318  -1272  -1596  -1612 
     27 :  -1500  -1585  -1176  -1252  -1313  -1463  -1478 
    # Map  BB_SH  Measured Current
      1 :   -139   -141   -130   -169   -175   -187   -143 
      2 :   -150   -163   -139   -156   -145   -138   -174 
      3 :   -143   -128   -170   -162   -159   -168   -159 
      4 :   -145   -178   -129   -172   -146   -188   -163 
      5 :   -158   -146   -123   -162   -146   -148   -151 
      6 :   -154   -158   -159   -169   -177   -149   -142 
      7 :   -169   -179   -160   -168   -173   -163   -171 
      8 :   -156   -165   -177   -119   -166   -187   -147 
      9 :   -139   -158   -130   -156   -166   -139   -157 
     10 :   -176   -140   -165   -129   -140   -139   -160 
     11 :   -172   -167   -165   -176   -153   -151   -136 
     12 :   -138   -170   -133   -153   -152   -162   -174 
     13 :   -151   -174   -158   -156   -130   -157   -166 
     14 :   -157   -133   -162   -139   -163   -170   -167 
     15 :   -178   -137   -136   -145   -163   -158   -155 
     16 :   -156   -169   -144   -179   -156   -170   -130 
     17 :   -143   -140   -176   -135   -150   -165   -170 
     18 :   -181   -134   -180   -124   -182   -167   -157 
     19 :   -142   -168   -115   -144   -151   -179   -145 
     20 :   -165   -140   -168   -143   -162   -140   -161 
     21 :   -150   -126   -168   -138   -169   -153   -135 
     22 :   -153   -137   -175   -144   -156   -163   -160 
     23 :   -166   -144   -164   -162   -179   -130   -147 
     24 :   -135   -163   -168   -160   -141   -160   -153 
     25 :   -143   -152   -134   -150   -143   -139   -174 
     26 :   -156   -130   -174   -140   -136   -170   -172 
     27 :   -164   -161   -120   -130   -135   -156   -157 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1500  -1585  -1176  -1252  -1313  -1463  -1478 
      2 :  -1430  -1291  -1648  -1318  -1272  -1596  -1612 
      3 :  -1419  -1459  -1291  -1588  -1368  -1293  -1628 
      4 :  -1265  -1537  -1585  -1464  -1332  -1504  -1418 
      5 :  -1548  -1311  -1510  -1545  -1662  -1192  -1386 
      6 :  -1384  -1271  -1608  -1364  -1454  -1534  -1454 
      7 :  -1419  -1197  -1578  -1299  -1594  -1426  -1270 
      8 :  -1558  -1332  -1578  -1302  -1542  -1324  -1507 
      9 :  -1311  -1532  -1066  -1379  -1430  -1687  -1389 
     10 :  -1676  -1289  -1641  -1175  -1672  -1534  -1450 
     11 :  -1340  -1300  -1681  -1287  -1465  -1537  -1593 
     12 :  -1437  -1602  -1346  -1669  -1471  -1604  -1228 
     13 :  -1622  -1317  -1235  -1361  -1534  -1441  -1470 
     14 :  -1460  -1270  -1523  -1304  -1545  -1555  -1577 
     15 :  -1417  -1599  -1500  -1681  -1250  -1460  -1614 
     16 :  -1324  -1585  -1288  -1476  -1404  -1556  -1617 
     17 :  -1554  -1560  -1544  -1589  -1409  -1426  -1256 
     18 :  -1595  -1296  -1539  -1196  -1276  -1302  -1520 
     19 :  -1273  -1444  -1196  -1452  -1524  -1280  -1495 
     20 :  -1418  -1475  -1593  -1088  -1586  -1700  -1386 
     21 :  -1531  -1583  -1509  -1503  -1656  -1570  -1632 
     22 :  -1381  -1397  -1471  -1632  -1697  -1452  -1334 
     23 :  -1436  -1405  -1139  -1466  -1502  -1425  -1493 
     24 :  -1330  -1626  -1217  -1624  -1376  -1842  -1593 
     25 :  -1345  -1193  -1607  -1536  -1529  -1556  -1524 
     26 :  -1410  -1482  -1285  -1473  -1385  -1324  -1589 
     27 :  -1339  -1336  -1244  -1588  -1634  -1763  -1325 
    # Map  BB_TESTMAP  Measured Current
      1 :   -164   -161   -120   -130   -135   -156   -157 
      2 :   -156   -130   -174   -140   -136   -170   -172 
      3 :   -143   -152   -134   -150   -143   -139   -174 
      4 :   -135   -163   -168   -160   -141   -160   -153 
      5 :   -166   -144   -164   -162   -179   -130   -147 
      6 :   -153   -137   -175   -144   -156   -163   -160 
      7 :   -150   -126   -168   -138   -169   -153   -135 
      8 :   -165   -140   -168   -143   -162   -140   -161 
      9 :   -142   -168   -115   -144   -151   -179   -145 
     10 :   -181   -134   -180   -124   -182   -167   -157 
     11 :   -143   -140   -176   -135   -150   -165   -170 
     12 :   -156   -169   -144   -179   -156   -170   -130 
     13 :   -178   -137   -136   -145   -163   -158   -155 
     14 :   -152   -139   -162   -139   -163   -170   -167 
     15 :   -149   -175   -159   -160   -130   -157   -166 
     16 :   -143   -165   -138   -153   -152   -162   -174 
     17 :   -172   -162   -170   -172   -153   -151   -136 
     18 :   -176   -140   -165   -129   -140   -139   -160 
     19 :   -139   -158   -130   -156   -166   -139   -157 
     20 :   -156   -165   -177   -119   -166   -187   -147 
     21 :   -169   -179   -160   -168   -173   -163   -171 
     22 :   -154   -158   -159   -169   -177   -149   -142 
     23 :   -158   -146   -123   -162   -146   -148   -151 
     24 :   -145   -178   -129   -172   -146   -188   -163 
     25 :   -143   -128   -170   -162   -159   -168   -159 
     26 :   -150   -163   -139   -156   -145   -138   -174 
     27 :   -139   -141   -130   -169   -175   -187   -143 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.200 V  (1659)