    keyword=End_of_Run_2201
    ****************************
     Run Number: 2201
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BB cosmics check -- HV: BB_08007_June14_1.set test after rebooting crates
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=1   ps8=10   
    
    EVENTS   : [0]: 0            [+]: 0            [-]: 0            
    TIME     : [0]: 0.017 mins  [+]: 0.017 mins  [-]: 0.017 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.03200 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   0.00%      [+]:   0.00%      [-]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/0.0  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/0.0  Hz   
    T1[+] : 0.0/0.0  Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/0.0  Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/0.0  Hz   
    T1[-] : 0.0/0.0  Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/0.0  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T3[0] :      0/0        T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/0        
    T1[+] :      0/0        T2[+] :      0/0        T3[+] :      0/0        T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :      0/0        T8[+] :      0/0        
    T1[-] :      0/0        T2[-] :      0/0        T3[-] :      0/0        T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :      0/0        T8[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : -0.1094uA  BCM x3 : -0.0324uA  BCM x10: -0.0169uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.528E-07     BCM u3 [0]:-4.801E-08     BCM u10[0]:-2.006E-08     
    BCM u1 [+]:-1.528E-07     BCM u3 [+]:-4.801E-08     BCM u10[+]:-2.006E-08     
    BCM u1 [-]:-1.528E-07     BCM u3 [-]:-4.801E-08     BCM u10[-]:-2.006E-08     
    
    BCM d1 [0]:-6.594E-08     BCM d3 [0]:-1.685E-08     BCM d10[0]:-1.367E-08     
    BCM d1 [+]:-6.594E-08     BCM d3 [+]:-1.685E-08     BCM d10[+]:-1.367E-08     
    BCM d1 [-]:-6.594E-08     BCM d3 [-]:-1.685E-08     BCM d10[-]:-1.367E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2201 at Tue Jul 29 08:54:32 EDT 2008
    
    Wien angle : 90.2438
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0
    Left Arm arm angle : 15.0003
    Right Arm D1 momentum : HacR_D1_P0rb --- Invalid channel name
    Right Arm arm angle : HacR_alignAGL --- Invalid channel name
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 0
    Left Arm Top VDC Current : 1.2207
    Left Arm Bottom VDC Current : 1.2207
    -----
    Left Arm Q1 momentum : 0
    Left Arm Q1 power supply : MQ171LM --- Invalid channel name
    Left Arm Q1 gauss meter : 0.014641
    Left Arm Q2 gauss meter : 2.94e-05
    Left Arm Q2 power supply current : 0
    Left Arm Q2 momentum : 0
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.508806
    Left Arm Q3 gauss meter : 0.00079879
    Left Arm Q3 power supply current : 0
    Left Arm Q3 momentum : 0
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : HacR_Q1_P0rb --- Invalid channel name
    Right Arm Q1 power supply : MQ172RM --- Invalid channel name
    Right Arm Q1 gauss meter : HacR_Q1_LS450:FLD_DATA --- Invalid channel name
    Right Arm Q2 power supply current : HacR_Q2_HP3458A:IOUT --- Invalid channel name
    Right Arm Q2 momentum : HacR_Q2_P0rb --- Invalid channel name
    Right Arm Q2 gauss meter : HacR_Q2_LS450:FLD_DATA --- Invalid channel name
    Right Arm Q2 power supply polarity : HacR_VMIC1182:0_Ch17 --- Invalid channel name
    Right Arm D1 power supply current : HacR_D1_HP3458A:IOUT --- Invalid channel name
    Right Arm D1 momentum : HacR_D1_P0rb --- Invalid channel name
    Right Arm D1 NMR : HacR_D1_NMR:SIG --- Invalid channel name
    Right Arm Q3 power supply current : HacR_Q3_HP3458A:IOUT --- Invalid channel name
    Right Arm Q3 momentum : HacR_Q3_P0rb --- Invalid channel name
    Right Arm Q3 gauss meter : HacR_Q3_LS450:FLD_DATA --- Invalid channel name
    Right Arm Q3 power supply polarity : HacR_VMIC1182:0_Ch26 --- Invalid channel name
    -----
    BigBite magnet current setpoint : MBIGBOX --- Invalid channel name
    BigBite magnet current readback : MBIGBOXM --- Invalid channel name
    BigBite Gaussmeter readback : HacR_BB_LS450:FLD_DATA --- Invalid channel name
    -----
    Average current of the two cavities : hac_bcm_average --- Invalid channel name
    Current on Unser monitor : hac_unser_current --- Invalid channel name
    Current on Upstream bcm : hac_bcm_dvm1_current --- Invalid channel name
    Current on Downstream bcm : hac_bcm_dvm2_current --- Invalid channel name
    Upstream Cavity Coefficient : hac_bcm_A1 --- Invalid channel name
    Downstream Cavity Coefficient : hac_bcm_A2 --- Invalid channel name
    Current on IBC0L02 (source) : 5.85569e-38
    Hall C Current : -0.203409
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 0
    Hall C energy (hallc_MeV) : 0
    Delta(E)/E width (MV_AI_DXWID) : 0.396011
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.0572266
    HacL_HPE1313A:0_Ch58 : -0.214355
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : 0.113281
    -----
    Right Arm Collimator : HacR_COL:ENC --- Invalid channel name
    HacR_HPE1313A:0_Ch58 : HacR_HPE1313A:0_Ch58 --- Invalid channel name
    HacR_HPE1313A:0_Ch55 : HacR_HPE1313A:0_Ch55 --- Invalid channel name
    HacR_HPE1313A:0_Ch54 : HacR_HPE1313A:0_Ch54 --- Invalid channel name
    -----
    Wien angle : 90.2438
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2068.5
    Wien field : 60.156
    Laser attenuation Hall A : 50
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Pair
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Pair
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.92298
    SLI vert. size mm : 0
    SLI y position : 1.90047
    -----
    Target : haBDSSELECT --- Invalid channel name
    fan frequency loop 1 : haL1_Fan_frequency_R --- Invalid channel name
    fan frequency loop 3 : haL3_Fan_frequency_R --- Invalid channel name
    Encoder position : haBDSPOS.VAL --- Invalid channel name
    Target type : haBDSPOS --- Invalid channel name
    temperature loop 1(1) : haITC502_1_Sensor_1_R --- Invalid channel name
    temperature loop 1(2) : haITC502_1_Sensor_2_R --- Invalid channel name
    temperature loop 1(3) : haITC502_1_Sensor_3_R --- Invalid channel name
    temperature loop 3(1) : haITC502_3_Sensor_1_R --- Invalid channel name
    temperature loop 3(2) : haITC502_3_Sensor_2_R --- Invalid channel name
    temperature loop 3(3) : haITC502_3_Sensor_3_R --- Invalid channel name
    Heat exchange LH2 : haL1_Cernox_HX_R --- Invalid channel name
    Heat exchange LH2 : haL3_Cernox_HX_R --- Invalid channel name
    HPH H2 loop 1 : haL1_hp_power_R --- Invalid channel name
    HPH H2 loop 3 : haL3_hp_power_R --- Invalid channel name
    -----