keyword=S2m Cabling, Patch Panel, ADC and TDC Maps
The cabling for S2m on the left HRS has been completed. Youcai and I
tested the signal and HV cables prior to re-installing the cables on the
detector stack. The ADC cables and path through the patch panel was
tested with a pulser. We found all the cables to be in good condition,
but we also found we could not get a signal through the tenth channel
of the Helga patch panel. We moved S2m R6 cable from this channel to an
available channel in the Betty patch panel B13.
The following provides the patch panel, ADC and TDC channel maps for S2m.
Note that the Helga patch panel is Ingrid on the lower platform beside
the fastbus crates:
Patch Panel S2m Cable ADC TDC
Channel ROC/Slot/Channel ROC/Slot/Channel
---------------------------------------------------------------------
B1 L1 3/25/16 4/25/16
B2 L2 3/25/17 4/25/17
B3 L3 3/25/18 4/25/18
B4 L4 3/25/19 4/25/19
B5 L5 3/25/20 4/25/20
B6 L6 3/25/21 4/25/21
B7 L7 3/25/22 4/25/22
B8 L8 3/25/23 4/25/23
B9 L9 3/25/24 4/25/24
B10 L10 3/25/25 4/25/25
B11 L11 3/25/26 4/25/26
B12 L12 3/25/27 4/25/27
Helga1 L13 3/25/28 4/25/28
Helga2 L14 3/25/29 4/25/29
Helga3 L15 3/25/30 4/25/30
Helga4 L16 3/25/31 4/25/31
---------------------------------------------------------------------
Helga5 R1 3/25/00 4/25/32
Helga6 R2 3/25/01 4/25/33
Helga7 R3 3/25/02 4/25/34
Helga8 R4 3/25/03 4/25/35
Helga9 R5 3/25/04 4/25/36
B13 R6 3/25/05 4/25/37
Helga17 R7 3/25/06 4/25/38
Helga18 R8 3/25/07 4/25/39
Helga19 R9 3/25/08 4/25/40
Helga20 R10 3/25/09 4/25/41
Helga21 R11 3/25/10 4/25/42
Helga22 R12 3/25/11 4/25/43
Helga23 R13 3/25/12 4/25/44
Helga24 R14 3/25/13 4/25/45
Helga25 R15 3/25/14 4/25/46
Helga26 R16 3/25/15 4/25/47
The S2m channels are plugged into the TS scaler module in slot # 9.
The left channels 1-16 are in the bottom input and the right channels
1-16 are in the top ECL input.
A copy of this log entry has been emailed to: ycwang@jlab.org,camsonne@jlab.org,kalyan@jlab.org