    keyword=End_of_Run_1615
    ****************************
     Run Number: 1615
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=shower test
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=1   ps7=1   ps8=65535   
    
    EVENTS   : [0]: 14646        [+]: 13354        [-]: 13326        
    TIME     : [0]: 0.238 mins  [+]: 0.217 mins  [-]: 0.217 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       -12.17289 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]: -6542309.40%      [+]: -6543381.90%      [-]: -6541519.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/5.9  Hz   T4[0] : 0.0/331.0 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 0.0/0.0  Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 0.0/7.1  Hz   T4[+] : 0.0/335.3 Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 0.0/0.0  Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/5.7  Hz   T4[-] : 0.0/332.6 Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T3[0] :      0/84       T4[0] :      0/4736     T5[0] :      0/0        T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/14652    
    T1[+] :      0/0        T2[+] :      0/0        T3[+] :      0/93       T4[+] :      0/4373     T5[+] :      0/0        T6[+] :      0/0        T7[+] :      0/0        T8[+] :      0/13357    
    T1[-] :      0/0        T2[-] :      0/0        T3[-] :      0/74       T4[-] :      0/4330     T5[-] :      0/0        T6[-] :      0/0        T7[-] :      0/0        T8[-] :      0/13333    
    
    AVERAGE CURRENT
    BCM x1 : -0.0216uA  BCM x3 : 0.0056 uA  BCM x10: -0.0089uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :1.496E+04 ppm     BCM u3 :     5382 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:3.797E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.242E-07      BCM u3 [0]:4.028E-07      BCM u10[0]:-2.659E-07     
    BCM u1 [+]:3.037E-07      BCM u3 [+]:3.711E-07      BCM u10[+]:-2.423E-07     
    BCM u1 [-]:2.942E-07      BCM u3 [-]:3.665E-07      BCM u10[-]:-2.424E-07     
    
    BCM d1 [0]:-9.435E-07     BCM d3 [0]:-2.412E-07     BCM d10[0]:1.182E-08      
    BCM d1 [+]:-8.601E-07     BCM d3 [+]:-2.198E-07     BCM d10[+]:1.165E-08      
    BCM d1 [-]:-8.586E-07     BCM d3 [-]:-2.195E-07     BCM d10[-]:1.078E-08      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1615 at Tue Sep 23 11:18:37 EDT 2008
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.0156334
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.00427793
    Right Arm arm angle : 0.197
    HALLA:p : HALLA:p --- Invalid channel name
    HALLA:dpp : HALLA:dpp --- Invalid channel name
    Tiefenbach Hall A energy : 0
    Left Arm Top VDC Current : 1.31836
    Left Arm Bottom VDC Current : 1.41602
    -----
    Left Arm Q1 momentum : 0.223851
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.014616
    Left Arm Q2 gauss meter : 5.77e-05
    Left Arm Q2 power supply current : 0
    Left Arm Q2 momentum : 0.000414779
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0
    Left Arm D1 momentum : 0.0156334
    Left Arm D1 NMR : 0.158021
    Left Arm Q3 gauss meter : 0.000786
    Left Arm Q3 power supply current : 0
    Left Arm Q3 momentum : 0.000105073
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00282078
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : 1.81e-05
    Right Arm Q2 power supply current : -0.000195962
    Right Arm Q2 momentum : -5.4984e-07
    Right Arm Q2 gauss meter : -0.0002731
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.00267228
    Right Arm D1 momentum : 0.0043199
    Right Arm D1 NMR : 0.298178
    Right Arm Q3 power supply current : -8.96713e-05
    Right Arm Q3 momentum : -1.87797e-07
    Right Arm Q3 gauss meter : -0.0002738
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.0020848
    -----
    Average current of the two cavities : hac_bcm_average --- Invalid channel name
    Current on Unser monitor : hac_unser_current --- Invalid channel name
    Current on Upstream bcm : hac_bcm_dvm1_current --- Invalid channel name
    Current on Downstream bcm : hac_bcm_dvm2_current --- Invalid channel name
    Upstream Cavity Coefficient : hac_bcm_A1 --- Invalid channel name
    Downstream Cavity Coefficient : hac_bcm_A2 --- Invalid channel name
    Current on IBC0L02 (source) : 5.85569e-38
    Hall C Current : 0.406062
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : HALLA:p --- Invalid channel name
    Hall A momentum orbit correction (dpp) : HALLA:dpp --- Invalid channel name
    Hall A setup momentum (MMSHLAE) : 1232.64
    Hall A energy (halla_MeV) : 0
    Hall C energy (hallc_MeV) : 0
    Delta(E)/E width (MV_AI_DXWID) : 0.891683
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.0575195
    HacL_HPE1313A:0_Ch58 : -0.213379
    HacL_HPE1313A:0_Ch55 : 22.8516
    HacL_HPE1313A:0_Ch54 : 0.11084
    -----
    Right Arm Collimator : -0.00874023
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.0703
    HacR_HPE1313A:0_Ch54 : -0.987305
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -2
    Wien field : 0
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Pair
    G0 Helicity Cycle Rate Set : 250 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Pair
    G0 Helicity Cycle Rate Read : 250 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0
    SLI vert. size mm : 0
    SLI y position : 0
    -----
    Target : Clear
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 0
    Target type : 0
    temperature loop 1(1) : 0
    temperature loop 1(2) : 0
    temperature loop 1(3) : 0
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 0
    Heat exchange LH2 : 0
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 0.011068
    -----