243468 09/30/08 23:00 adev BigBite WireChamber Measured Voltage change!
243467 09/30/08 22:57 a-onl Start_Run_1646,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Shower and Wire Chamber Test!!!
243466 09/30/08 22:57 a-onl End_of_Run_1645
243465 09/30/08 22:53 a-onl Start_Run_1645,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Shower and Wire Chamber Test!!!
243464 09/30/08 22:49 adev BigBite WireChamber Measured Voltage change!
243463 09/30/08 22:47 a-onl End_of_Run_1644
243462 09/30/08 22:30 a-onl Start_Run_1644,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber remote power supply 3.5V
243461 09/30/08 22:29 a-onl End_of_Run_1643
243460 09/30/08 22:29 adev BigBite WireChamber Threshold change!
243459 09/30/08 22:12 a-onl Start_Run_1643,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber remote power supply 3.1V
243458 09/30/08 22:11 a-onl End_of_Run_1642
243457 09/30/08 21:54 a-onl Start_Run_1642,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber remote power supply 3.06V
243456 09/30/08 21:53 a-onl End_of_Run_1641
243455 09/30/08 21:36 a-onl Start_Run_1641,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber local power supply 3.1V
243454 09/30/08 21:25 a-onl End_of_Run_1640
243453 09/30/08 21:08 a-onl Start_Run_1640,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber local power supply 3.1V
243452 09/30/08 21:07 a-onl End_of_Run_1639
243451 09/30/08 20:51 a-onl Start_Run_1639,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=random trigger chamber local power supply 3.1V
243450 09/30/08 20:50 a-onl End_of_Run_1638
243449 09/30/08 18:48 a-onl Start_Run_1638,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=shower test - new cosmic trigger setup
243448 09/30/08 18:43 a-onl End_of_Run_1637
243447 09/30/08 16:47 a-onl Start_Run_1637,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Wire Chamber local power supply 3.1V
243446 09/30/08 16:40 a-onl End_of_Run_1636
243445 09/30/08 16:24 a-onl Start_Run_1636,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Wire Chamber local power supply 3.1V
243444 09/30/08 15:54 a-onl End_of_Run_1635
243443 09/30/08 15:36 a-onl End_of_Run_1634
243442 09/30/08 15:19 a-onl Start_Run_1634,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Wire Chamber remote power supply 3.1V
243441 09/30/08 15:18 a-onl End_of_Run_1633
243440 09/30/08 15:02 adev BigBite WireChamber Threshold change!
243439 09/30/08 15:01 a-onl Start_Run_1633,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=Wire Chamber remote power supply 3.1V
243438 09/30/08 14:59 a-onl End_of_Run_1632
243437 09/30/08 14:21 Kalyan HV set for run 1632
Monday
243436 09/29/08 18:25 a-onl Start_Run_1632,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=shower test
243435 09/29/08 17:51 a-onl End_of_Run_1631
243434 09/29/08 17:50 a-onl Start_Run_1631,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=DAQ test
243433 09/29/08 17:24 a-onl End_of_Run_1630
243432 09/29/08 17:20 a-onl Start_Run_1630,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=DAQ test
243431 09/29/08 15:44 a-onl End_of_Run_1629
243430 09/29/08 15:40 a-onl Start_Run_1629,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=DAQ test
243429 09/29/08 15:37 a-onl End_of_Run_1628
243428 09/29/08 15:35 a-onl Start_Run_1628,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=DAQ test
243427 09/29/08 14:50 a-onl End_of_Run_1627
243426 09/29/08 14:30 Moffit F1 tdc change..
243425 09/29/08 14:25 a-onl Start_Run_1627,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=F1 TDC test
243424 09/29/08 14:24 a-onl End_of_Run_1624
243423 09/29/08 14:11 a-onl End_of_Run_1624
243422 09/29/08 13:37 a-onl End_of_Run_1624
243421 09/29/08 10:31 Yi Qiang Water NMR Calibration
Sunday
243420 09/28/08 17:44 a-onl Start_Run_1624,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=BB calorimeter + scint test
243419 09/28/08 17:13 adev BigBite WireChamber HVGUI Start!
243418 09/28/08 15:48 a-onl End_of_Run_1623
Friday
243417 09/26/08 16:18 Jin Huang Target: Verticle Coil Polarity Inversed
243416 09/26/08 11:27 adev BigBite WireChamber Measured Voltage change!
243415 09/26/08 09:28 R. Michaels Right HRS scalers dropped
243414 09/26/08 09:08 V. Sulkosky Rebooted IOCHA5 for BCM
Thursday
243413 09/25/08 23:43 Yi Qiang First Water Signal in Hall !
243412 09/25/08 17:57 a-onl Start_Run_1623,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=BB calorimeter + scint test
243411 09/25/08 17:50 a-onl Start_Run_1622,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=BB calorimeter + scint test
243410 09/25/08 15:37 adev BigBite WireChamber HVGUI Start!
243409 09/25/08 15:16 Kalyan BigBite DAQ is up and running again
243408 09/25/08 15:08 a-onl End_of_Run_1621
243407 09/25/08 15:08 kalyan Compressed air lines connected for BigBite PMTs
243406 09/25/08 15:08 a-onl Start_Run_1621,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=DAQ test
Wednesday
243405 09/24/08 12:33 Kalyan CPU borads for upgrade to Vxworks 5.5
243404 09/24/08 09:47 K DAQ down
243403 09/24/08 09:42 a-onl End_of_Run_1620
Tuesday
243402 09/23/08 17:42 a-onl Start_Run_1620,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=chamber test 3.5V threshold and 1600V
243401 09/23/08 16:57 adev BigBite WireChamber Threshold change!
243400 09/23/08 16:51 a-onl Start_Run_1619,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=chamber test 3.5V threshold and 1600V
243399 09/23/08 16:50 a-onl End_of_Run_1618
243398 09/23/08 16:27 a-onl Start_Run_1618,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=chamber test
243397 09/23/08 16:24 a-onl End_of_Run_1617
243396 09/23/08 16:24 a-onl Start_Run_1617,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=shower test
243395 09/23/08 16:23 a-onl End_of_Run_1615
243394 09/23/08 16:19 V. Sulkosky Ped Suppression Removed for Helicity and Target Spin
243393 09/23/08 16:15 adev BigBite WireChamber Threshold change!
243392 09/23/08 15:54 adev BigBite WireChamber Threshold change!
243391 09/23/08 15:13 adev BigBite WireChamber HVGUI Start!
243390 09/23/08 11:19 a-onl End_of_Run_1615
Monday
243389 09/22/08 18:25 a-onl Start_Run_1615,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=shower test
243388 09/22/08 18:23 a-onl End_of_Run_1614
243387 09/22/08 18:13 adev BigBite WireChamber HVGUI Start!
243386 09/22/08 17:55 Kalyan Cosmic trigger for BB lead-glass blocks
243385 09/22/08 17:44 a-onl Start_Run_1614,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=cosmic trigger test
243384 09/22/08 17:43 a-onl End_of_Run_1613
243383 09/22/08 17:18 a-onl Start_Run_1613,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=cosmic trigger test
243382 09/22/08 09:36 a-onl End_of_Run_1611
Sunday
243381 09/21/08 17:48 a-onl Start_Run_1611,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test!
243380 09/21/08 16:17 Kalyan bbts1 crate in the readout as ROC12
243379 09/21/08 15:51 a-onl End_of_Run_1610
243378 09/21/08 15:23 a-onl Start_Run_1610,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=test
Saturday
243377 09/20/08 21:19 Jack VDC gas flowing
243376 09/20/08 14:34 a-onl End_of_Run_1609
Friday
243375 09/19/08 18:42 a-onl Start_Run_1609,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test
243374 09/19/08 18:40 a-onl End_of_Run_1608
243373 09/19/08 18:39 a-onl Start_Run_1608,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243372 09/19/08 18:31 a-onl End_of_Run_1607
243371 09/19/08 18:19 a-onl Start_Run_1607,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243370 09/19/08 18:15 a-onl Start_Run_1606,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243369 09/19/08 18:10 a-onl Start_Run_1605,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243368 09/19/08 18:02 a-onl Start_Run_1604,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243367 09/19/08 17:52 a-onl Start_Run_1603,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243366 09/19/08 17:25 Jin Huang RICH lib added to replay softwares
243365 09/19/08 17:15 a-onl End_of_Run_1602
243364 09/19/08 17:03 a-onl Start_Run_1602,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243363 09/19/08 15:48 a-onl Start_Run_1601,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243362 09/19/08 15:28 a-onl End_of_Run_1600
243361 09/19/08 15:16 a-onl Start_Run_1600,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243360 09/19/08 14:22 a-onl End_of_Run_1599
243359 09/19/08 14:21 a-onl Start_Run_1599,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243358 09/19/08 13:48 a-onl End_of_Run_1598
243357 09/19/08 13:46 a-onl Start_Run_1598,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243356 09/19/08 12:40 a-onl Start_Run_1596,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=
243355 09/19/08 10:54 R. Michaels R-HRS DAQ ready, runs 2.6
243354 09/19/08 10:14 a-onl End_of_Run_1594
Thursday
243353 09/18/08 17:40 a-onl Start_Run_1594,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber front and back coincidence trigger!
243352 09/18/08 17:20 a-onl End_of_Run_1593
243351 09/18/08 17:16 a-onl Start_Run_1593,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber pulser
243350 09/18/08 17:15 a-onl End_of_Run_1592
243349 09/18/08 17:15 a-onl Start_Run_1592,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber pulser
243348 09/18/08 16:19 xqian Noise Cross-talk on BigBite Wire Chamber
243347 09/18/08 16:11 a-onl End_of_Run_1591
243346 09/18/08 16:10 a-onl Start_Run_1591,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber pulser
243345 09/18/08 16:08 a-onl End_of_Run_1590
243344 09/18/08 16:07 a-onl Start_Run_1590,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber pulser
243343 09/18/08 16:05 a-onl End_of_Run_1589
243342 09/18/08 16:04 a-onl Start_Run_1589,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243341 09/18/08 15:38 Jack Left Arm Detector Stack is out
243340 09/18/08 15:19 a-onl Start_Run_1588,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243339 09/18/08 15:19 a-onl End_of_Run_1587
243338 09/18/08 14:59 a-onl Start_Run_1587,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243337 09/18/08 14:58 a-onl End_of_Run_1586
243336 09/18/08 14:47 a-onl Start_Run_1586,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243335 09/18/08 14:46 a-onl End_of_Run_1585
243334 09/18/08 14:37 Moffit Left Arm TIR/TS cable disconnected
243333 09/18/08 14:31 a-onl Start_Run_1585,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243332 09/18/08 14:01 a-onl End_of_Run_1584
243331 09/18/08 14:00 a-onl Start_Run_1584,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243330 09/18/08 13:34 a-onl End_of_Run_1583
243329 09/18/08 12:24 a-onl Start_Run_1583,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243328 09/18/08 12:13 a-onl End_of_Run_1582
243327 09/18/08 11:49 a-onl Start_Run_1582,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243326 09/18/08 11:45 R. Michaels Modified ts_scaler.crl (LHRS)
243325 09/18/08 11:41 a-onl End_of_Run_1581
243324 09/18/08 11:19 Jack Dry air to the hall
243323 09/18/08 11:03 a-onl Start_Run_1581,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 Test
243322 09/18/08 09:13 a-onl End_of_Run_1580
243321 09/18/08 09:13 a-onl Start_Run_1580,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Ch1+Ch2 test!
243320 09/18/08 09:11 a-onl End_of_Run_1579
243319 09/18/08 02:42 a-onl Start_Run_1579,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Ch1+Ch2 test!
243318 09/18/08 02:41 a-onl End_of_Run_1578
243317 09/18/08 01:23 a-onl Start_Run_1578,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Ch1+Ch2 test!
243316 09/18/08 01:22 a-onl End_of_Run_1577
Wednesday
243315 09/17/08 21:20 V. Sulkosky Target Spin Signal Added to TIR
243314 09/17/08 21:14 V. Sulkosky Helicity and Target Spin Signal in ADC
243313 09/17/08 20:40 a-onl Start_Run_1577,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Test run
243312 09/17/08 20:03 a-onl Start_Run_1576,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Test of target spin and helicity ADC Info
243311 09/17/08 20:02 a-onl End_of_Run_1575
243310 09/17/08 20:02 a-onl Start_Run_1575,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243309 09/17/08 17:16 a-onl End_of_Run_1574
243308 09/17/08 17:12 a-onl Start_Run_1574,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243307 09/17/08 15:44 a-onl End_of_Run_1572
243306 09/17/08 14:39 a-onl Start_Run_1572,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243305 09/17/08 14:37 a-onl End_of_Run_1571
243304 09/17/08 14:36 a-onl Start_Run_1571,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243303 09/17/08 14:32 a-onl End_of_Run_1569
243302 09/17/08 14:31 a-onl Start_Run_1569,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243301 09/17/08 14:27 a-onl End_of_Run_1568
243300 09/17/08 14:26 a-onl Start_Run_1568,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243299 09/17/08 14:25 a-onl End_of_Run_1567
243298 09/17/08 14:24 a-onl Start_Run_1567,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243297 09/17/08 14:17 a-onl End_of_Run_1566
243296 09/17/08 14:16 a-onl Start_Run_1566,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243295 09/17/08 14:13 R. Michaels scaler swap on L-HRS
243294 09/17/08 14:08 a-onl End_of_Run_1565
243293 09/17/08 14:08 a-onl Start_Run_1565,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243292 09/17/08 14:06 a-onl End_of_Run_1564
243291 09/17/08 13:59 a-onl Start_Run_1564,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243290 09/17/08 13:57 a-onl End_of_Run_1563
243289 09/17/08 13:57 a-onl Start_Run_1563,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243288 09/17/08 13:57 a-onl End_of_Run_1562
243287 09/17/08 13:45 a-onl Start_Run_1562,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=F1 TDC test
243286 09/17/08 09:41 a-onl End_of_Run_1561
Tuesday
243285 09/16/08 23:41 adev BigBite WireChamber Measured Voltage change!
243284 09/16/08 23:31 adev BigBite WireChamber Measured Voltage change!
243283 09/16/08 23:31 a-onl Start_Run_1561,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
243282 09/16/08 22:28 V. Sulkosky Re: Scaler gates and target signals in L-HRS
243281 09/16/08 22:06 a-onl End_of_Run_1560
243280 09/16/08 18:01 a-onl Start_Run_1560,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
0 09/16/08 18:00 no_name no_key
243278 09/16/08 18:00 a-onl End_of_Run_1559
243277 09/16/08 16:09 a-onl End_of_Run_1557
243276 09/16/08 15:56 a-onl Start_Run_1557,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
243275 09/16/08 15:46 a-onl End_of_Run_1550
243274 09/16/08 15:39 a-onl End_of_Run_1550
243273 09/16/08 15:39 a-onl End_of_Run_1550
243272 09/16/08 15:37 a-onl End_of_Run_1550
243271 09/16/08 15:32 a-onl End_of_Run_1550
243270 09/16/08 15:26 a-onl Start_Run_1550,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
243269 09/16/08 15:16 a-onl End_of_Run_1549
243268 09/16/08 15:04 a-onl Start_Run_1549,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
243267 09/16/08 15:03 a-onl End_of_Run_1548
243266 09/16/08 14:29 a-onl Start_Run_1548,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BigBite Wire Chamber Test
243265 09/16/08 14:13 a-onl End_of_Run_1547
243264 09/16/08 14:13 a-onl Start_Run_1547,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BB Scint F1 TDC test
243263 09/16/08 14:08 Jin Huang Target: Spin Signal to IOC changed to TTL level
243262 09/16/08 13:53 a-onl End_of_Run_1546
243261 09/16/08 13:43 a-onl Start_Run_1546,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=BB Scint F1 TDC test
243260 09/16/08 13:34 a-onl End_of_Run_1545
243259 09/16/08 12:33 a-onl Start_Run_1545,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 2.0V Pulser
243258 09/16/08 12:15 adev BigBite WireChamber Measured Voltage change!
243257 09/16/08 12:11 a-onl End_of_Run_1544
243256 09/16/08 12:07 a-onl Start_Run_1544,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 2.0V Pulser
243255 09/16/08 12:03 adev BigBite WireChamber Measured Voltage change!
243254 09/16/08 12:03 a-onl End_of_Run_1543
243253 09/16/08 11:57 a-onl Start_Run_1543,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 1.7V Pulser with 1600V
243252 09/16/08 11:54 a-onl End_of_Run_1542
243251 09/16/08 11:49 a-onl Start_Run_1542,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 1.7V Pulser
243250 09/16/08 11:46 a-onl End_of_Run_1541
243249 09/16/08 11:42 a-onl Start_Run_1541,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 3.0V Pulser
243248 09/16/08 11:17 a-onl End_of_Run_1540
243247 09/16/08 11:14 a-onl Start_Run_1540,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 3.0V Pulser
243246 09/16/08 11:12 a-onl End_of_Run_1539
243245 09/16/08 11:11 adev BigBite WireChamber Measured Voltage change!
243244 09/16/08 11:09 a-onl Start_Run_1539,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber Test 3.0V Pulser
243243 09/16/08 11:05 a-onl End_of_Run_1538
Monday
243242 09/15/08 23:10 adev BigBite WireChamber Measured Voltage change!
243241 09/15/08 23:06 a-onl Start_Run_1538,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test! front and back coincidence trigger
243240 09/15/08 23:05 a-onl End_of_Run_1537
243239 09/15/08 22:45 a-onl Start_Run_1537,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test! front and back coincidence trigger
243238 09/15/08 22:44 a-onl End_of_Run_1536
243237 09/15/08 22:37 a-onl Start_Run_1536,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test!
243236 09/15/08 22:23 a-onl End_of_Run_1535
243235 09/15/08 22:19 a-onl Start_Run_1535,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test!
243234 09/15/08 21:54 a-onl End_of_Run_1534
243233 09/15/08 21:48 a-onl Start_Run_1534,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test!
243232 09/15/08 21:47 adev BigBite WireChamber Measured Voltage change!
243231 09/15/08 21:40 a-onl End_of_Run_1533
243230 09/15/08 21:36 a-onl Start_Run_1533,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=wire chamber test!
243229 09/15/08 21:31 a-onl End_of_Run_1532
243228 09/15/08 21:23 a-onl Start_Run_1532,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T3 = T8 pulser
243227 09/15/08 21:15 a-onl End_of_Run_1531
243226 09/15/08 21:13 a-onl Start_Run_1531,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243225 09/15/08 21:12 a-onl End_of_Run_1530
243224 09/15/08 21:10 a-onl Start_Run_1530,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243223 09/15/08 20:44 a-onl End_of_Run_1529
243222 09/15/08 20:38 a-onl Start_Run_1529,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243221 09/15/08 20:17 a-onl End_of_Run_1528
243220 09/15/08 20:10 a-onl Start_Run_1528,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243219 09/15/08 20:09 a-onl End_of_Run_1527
243218 09/15/08 20:09 a-onl Start_Run_1527,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243217 09/15/08 20:08 a-onl End_of_Run_1526
243216 09/15/08 20:04 a-onl Start_Run_1526,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Wire Chamber test!
243215 09/15/08 20:02 a-onl End_of_Run_1525
243214 09/15/08 19:06 a-onl Start_Run_1525,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T3 = OR of S2m paddles
243213 09/15/08 19:05 a-onl End_of_Run_1524
243212 09/15/08 18:57 a-onl Start_Run_1524,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T3 = OR of S2m paddles
243211 09/15/08 18:46 Kalyan Scaler gates and target signals in L-HRS
243210 09/15/08 18:45 Kalyan Scaler gates and target signals in L-HRS
243209 09/15/08 18:43 a-onl End_of_Run_1522
243208 09/15/08 18:42 a-onl Start_Run_1522,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T8 test run
243207 09/15/08 18:42 a-onl End_of_Run_1522
243206 09/15/08 17:31 a-onl Start_Run_1521,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T8 test run
243205 09/15/08 17:30 a-onl End_of_Run_1520
243204 09/15/08 17:21 a-onl Start_Run_1520,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T8 test run
243203 09/15/08 17:11 Jin Huang hareboot12 set up for In Hall Target electronics
243202 09/15/08 16:55 a-onl End_of_Run_1519
243201 09/15/08 16:46 a-onl Start_Run_1519,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T8 test run
243200 09/15/08 15:56 brads Outside web access blocked for computers on Hall A subnets
243199 09/15/08 15:44 Jin Huang Proxy Setting to Access hareboot*
243198 09/15/08 11:48 a-onl End_of_Run_1517
243197 09/15/08 11:45 a-onl Start_Run_1517,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=T8 test run
243196 09/15/08 11:44 a-onl End_of_Run_1516
243195 09/15/08 11:42 a-onl Start_Run_1516,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text= T3 = "or" S2m for resolution tests
243194 09/15/08 11:38 a-onl Start_Run_1515,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Two Arm Config LHRS Cosmic Run
243193 09/15/08 11:38 a-onl End_of_Run_1515
243192 09/15/08 10:23 a-onl End_of_Run_1513
243191 09/15/08 10:16 adev BigBite WireChamber HVGUI Start!
243190 09/15/08 09:31 ycwang A1 information of cosmic test
243189 09/15/08 09:16 a-onl Start_Run_1513,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Two Arm Config LHRS Cosmic Run
243188 09/15/08 09:15 adev BigBite WireChamber Measured Voltage change!
243187 09/15/08 09:12 a-onl End_of_Run_1513
243186 09/15/08 09:05 adev BigBite WireChamber Measured Voltage change!
Sunday
243185 09/14/08 23:53 adev BigBite WireChamber Measured Voltage change!
243184 09/14/08 23:43 adev BigBite WireChamber Threshold change!
243183 09/14/08 23:32 adev BigBite WireChamber Measured Voltage change!
243182 09/14/08 18:57 V. Sulkosky Turned on LHRS VDC Discriminator Thresholds
243181 09/14/08 18:16 a-onl Start_Run_1513,Run_type=Cosmics,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=0,bbarm_theta=35,bbarm_zoff=0,comment_text=Two Arm Config LHRS Cosmic Run
243180 09/14/08 18:14 a-onl End_of_Run_1512
243179 09/14/08 18:07 a-onl Start_Run_1512,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two Arm Config T8 deadtime test
243178 09/14/08 18:05 a-onl End_of_Run_1511
243177 09/14/08 17:57 a-onl Start_Run_1511,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T8 deadtime test
243176 09/14/08 17:57 a-onl End_of_Run_1510
243175 09/14/08 17:52 a-onl Start_Run_1510,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T3 deadtime test
243174 09/14/08 17:48 a-onl End_of_Run_1509
243173 09/14/08 16:59 a-onl Start_Run_1509,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T3 deadtime test
243172 09/14/08 16:58 adev BigBite WireChamber Threshold change!
243171 09/14/08 16:22 a-onl End_of_Run_1508
243170 09/14/08 16:19 a-onl Start_Run_1508,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T8 deadtime test
243169 09/14/08 16:18 a-onl End_of_Run_1507
243168 09/14/08 16:06 a-onl Start_Run_1507,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BB T8 deadtime test
243167 09/14/08 16:06 a-onl End_of_Run_1506
243166 09/14/08 16:01 a-onl Start_Run_1506,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BB T1 deadtime test
243165 09/14/08 16:01 a-onl End_of_Run_1505
243164 09/14/08 15:57 a-onl Start_Run_1505,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BB T8 deadtime test
243163 09/14/08 15:49 a-onl End_of_Run_1504
243162 09/14/08 15:45 a-onl Start_Run_1504,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BB T3 deadtime test
243161 09/14/08 15:44 a-onl End_of_Run_1503
243160 09/14/08 15:28 a-onl Start_Run_1503,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T3 deadtime test
243159 09/14/08 13:51 adev BigBite WireChamber Threshold change!
243158 09/14/08 13:41 adev BigBite WireChamber Threshold change!
Saturday
243157 09/13/08 11:59 a-onl End_of_Run_1501
243156 09/13/08 11:53 a-onl Start_Run_1501,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T3 deadtime test
243155 09/13/08 11:52 a-onl End_of_Run_1500
243154 09/13/08 11:47 a-onl Start_Run_1500,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS T8 test
243153 09/13/08 11:46 a-onl End_of_Run_1499
243152 09/13/08 11:21 a-onl Start_Run_1499,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS test run
243151 09/13/08 11:20 a-onl End_of_Run_1498
243150 09/13/08 10:13 a-onl Start_Run_1498,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS test run
243149 09/13/08 10:11 a-onl End_of_Run_1497
243148 09/13/08 10:03 a-onl Start_Run_1497,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS test run
243147 09/13/08 09:52 a-onl Start_Run_1495,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=LHRS test run
243146 09/13/08 09:49 a-onl End_of_Run_1495
Friday
243145 09/12/08 22:38 adev BigBite WireChamber Threshold change!
243144 09/12/08 19:34 a-onl Start_Run_1495,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243143 09/12/08 19:34 a-onl End_of_Run_1495
243142 09/12/08 19:05 V. Sulkosky Re: S2m ADC Signals from Paddle 4 Resolved
243141 09/12/08 18:45 V. Sulkosky ADC in ROC 4 Slot 20 Removed
243140 09/12/08 18:01 a-onl Start_Run_1494,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243139 09/12/08 18:00 a-onl End_of_Run_1493
243138 09/12/08 17:50 a-onl Start_Run_1493,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243137 09/12/08 17:49 a-onl End_of_Run_1492
243136 09/12/08 17:48 a-onl Start_Run_1492,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243135 09/12/08 17:46 a-onl End_of_Run_1491
243134 09/12/08 17:45 a-onl Start_Run_1491,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243133 09/12/08 17:44 a-onl End_of_Run_1490
243132 09/12/08 17:43 a-onl Start_Run_1490,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243131 09/12/08 17:42 a-onl End_of_Run_1489
243130 09/12/08 17:40 a-onl Start_Run_1489,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243129 09/12/08 17:39 a-onl End_of_Run_1488
243128 09/12/08 17:37 a-onl Start_Run_1488,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=test run
243127 09/12/08 17:36 a-onl End_of_Run_1487
243126 09/12/08 17:28 a-onl Start_Run_1487,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243125 09/12/08 17:27 a-onl End_of_Run_1486
243124 09/12/08 17:25 a-onl Start_Run_1486,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243123 09/12/08 17:21 a-onl End_of_Run_1485
243122 09/12/08 17:20 a-onl Start_Run_1485,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243121 09/12/08 17:19 a-onl End_of_Run_1484
243120 09/12/08 17:19 a-onl Start_Run_1484,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243119 09/12/08 17:18 a-onl Start_Run_1483,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243118 09/12/08 17:18 a-onl End_of_Run_1483
243117 09/12/08 16:09 a-onl End_of_Run_1482
243116 09/12/08 16:06 a-onl Start_Run_1482,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243115 09/12/08 16:02 a-onl End_of_Run_1480
243114 09/12/08 15:58 a-onl Start_Run_1480,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243113 09/12/08 15:57 a-onl End_of_Run_1479
243112 09/12/08 15:44 a-onl Start_Run_1479,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243111 09/12/08 14:43 a-onl End_of_Run_1478
243110 09/12/08 09:33 a-onl Start_Run_1478,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243109 09/12/08 09:21 a-onl End_of_Run_1477
Thursday
243108 09/11/08 20:29 a-onl Start_Run_1477,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243107 09/11/08 20:19 a-onl Start_Run_1476,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243106 09/11/08 20:07 a-onl Start_Run_1475,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243105 09/11/08 20:05 a-onl End_of_Run_1474
243104 09/11/08 20:01 a-onl Start_Run_1474,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243103 09/11/08 19:56 a-onl End_of_Run_1473
243102 09/11/08 19:55 a-onl Start_Run_1473,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243101 09/11/08 19:53 a-onl End_of_Run_1472
243100 09/11/08 19:52 a-onl Start_Run_1472,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243099 09/11/08 19:50 a-onl End_of_Run_1471
243098 09/11/08 19:44 a-onl Start_Run_1471,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243097 09/11/08 19:35 a-onl End_of_Run_1470
243096 09/11/08 19:26 a-onl Start_Run_1470,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243095 09/11/08 19:19 a-onl Start_Run_1469,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243094 09/11/08 19:18 a-onl End_of_Run_1468
243093 09/11/08 19:17 a-onl Start_Run_1468,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243092 09/11/08 19:16 a-onl End_of_Run_1467
243091 09/11/08 19:13 a-onl Start_Run_1467,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243090 09/11/08 19:08 a-onl End_of_Run_1466
243089 09/11/08 19:07 a-onl Start_Run_1466,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243088 09/11/08 19:06 a-onl End_of_Run_1465
243087 09/11/08 19:05 a-onl Start_Run_1465,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243086 09/11/08 18:54 a-onl End_of_Run_1464
243085 09/11/08 18:53 a-onl Start_Run_1464,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243084 09/11/08 18:40 a-onl End_of_Run_1463
243083 09/11/08 18:39 a-onl Start_Run_1463,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243082 09/11/08 18:23 a-onl End_of_Run_1462
243081 09/11/08 18:22 a-onl Start_Run_1462,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243080 09/11/08 18:10 a-onl End_of_Run_1461
243079 09/11/08 18:09 a-onl Start_Run_1461,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243078 09/11/08 17:45 a-onl End_of_Run_1460
243077 09/11/08 17:44 a-onl Start_Run_1460,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243076 09/11/08 17:41 a-onl End_of_Run_1459
243075 09/11/08 17:41 a-onl Start_Run_1459,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243074 09/11/08 17:33 a-onl Start_Run_1458,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243073 09/11/08 16:06 adev BigBite WireChamber Threshold change!
243072 09/11/08 15:51 Jin Huang Target: Spin Signal Recovered
243071 09/11/08 15:35 a-onl End_of_Run_1456
243070 09/11/08 15:34 a-onl Start_Run_1456,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243069 09/11/08 14:54 Jin Huang Target: Spin Signal to Bigbite to be down for 1 hour
243068 09/11/08 14:33 a-onl End_of_Run_1454
243067 09/11/08 14:32 a-onl Start_Run_1454,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243066 09/11/08 14:32 a-onl Start_Run_1453,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243065 09/11/08 14:22 R. Michaels adaql2 rebuilt, CODA running
243064 09/11/08 14:17 a-onl Start_Run_1452,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=
243063 09/11/08 14:12 adev BigBite WireChamber Threshold change!
Wednesday
243062 09/10/08 18:22 adev BigBite WireChamber Measured Voltage change!
243061 09/10/08 18:11 adev BigBite WireChamber Measured Voltage change!
243060 09/10/08 18:11 V. Sulkosky A1 Aerogel Discriminator Threshold Changed (30 mV)
243059 09/10/08 18:05 V. Sulkosky Re: L-HRS DAQ problems fixed
243058 09/10/08 17:42 V. Sulkosky S2m ADC Signals from Paddle 4 Resolved(?)
243057 09/10/08 14:46 atrig Trigger-Download
243056 09/10/08 13:08 a-onl Start_Run_1451,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BigBite Wire Chamber, threshold scan 5.0 + 9 + 9
243055 09/10/08 13:07 a-onl End_of_Run_1451
243054 09/10/08 01:03 adev BigBite WireChamber Threshold change!
243053 09/10/08 01:00 a-onl Start_Run_1451,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BigBite Wire Chamber, threshold scan 5.0 + 9 + 9
243052 09/10/08 00:59 a-onl End_of_Run_1450
Tuesday
243051 09/09/08 21:03 a-onl Start_Run_1450,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=BigBite Wire Chamber, threshold scan
243050 09/09/08 18:41 a-onl End_of_Run_1449
243049 09/09/08 18:33 a-onl Start_Run_1449,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config
243048 09/09/08 18:31 a-onl End_of_Run_1448
243047 09/09/08 18:22 a-onl Start_Run_1448,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config ped. suppression off
243046 09/09/08 18:19 a-onl End_of_Run_1447
243045 09/09/08 18:11 a-onl Start_Run_1447,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243044 09/09/08 18:10 a-onl End_of_Run_1446
243043 09/09/08 18:09 a-onl Start_Run_1446,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243042 09/09/08 18:06 a-onl End_of_Run_1445
243041 09/09/08 17:42 a-onl Start_Run_1445,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243040 09/09/08 17:41 a-onl End_of_Run_1444
243039 09/09/08 17:09 a-onl Start_Run_1444,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243038 09/09/08 17:08 a-onl End_of_Run_1443
243037 09/09/08 16:27 a-onl Start_Run_1443,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243036 09/09/08 16:27 a-onl End_of_Run_1443
243035 09/09/08 16:22 a-onl Start_Run_1442,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243034 09/09/08 16:22 a-onl End_of_Run_1441
243033 09/09/08 16:18 a-onl Start_Run_1441,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243032 09/09/08 16:17 a-onl End_of_Run_1440
243031 09/09/08 16:09 a-onl Start_Run_1440,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243030 09/09/08 15:59 a-onl End_of_Run_1439
243029 09/09/08 15:57 a-onl Start_Run_1439,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243028 09/09/08 15:56 a-onl End_of_Run_1438
243027 09/09/08 15:55 a-onl Start_Run_1438,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243026 09/09/08 15:54 a-onl End_of_Run_1437
243025 09/09/08 15:54 a-onl Start_Run_1437,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243024 09/09/08 15:52 a-onl End_of_Run_1436
243023 09/09/08 15:51 a-onl Start_Run_1436,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243022 09/09/08 15:50 a-onl End_of_Run_1435
243021 09/09/08 15:48 a-onl Start_Run_1435,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243020 09/09/08 15:45 a-onl Start_Run_1434,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243019 09/09/08 15:43 a-onl End_of_Run_1433
243018 09/09/08 15:42 a-onl Start_Run_1433,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243017 09/09/08 15:42 a-onl End_of_Run_1433
243016 09/09/08 15:28 a-onl Start_Run_1432,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243015 09/09/08 15:27 a-onl End_of_Run_1431
243014 09/09/08 15:19 a-onl Start_Run_1431,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243013 09/09/08 15:18 a-onl End_of_Run_1430
243012 09/09/08 15:08 a-onl Start_Run_1430,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243011 09/09/08 15:06 a-onl End_of_Run_1429
243010 09/09/08 14:57 a-onl Start_Run_1429,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243009 09/09/08 14:56 a-onl End_of_Run_1428
243008 09/09/08 14:52 a-onl Start_Run_1428,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243007 09/09/08 14:50 a-onl End_of_Run_1427
243006 09/09/08 14:33 a-onl Start_Run_1427,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243005 09/09/08 14:26 a-onl Start_Run_1426,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,comment_text=Two arm config test
243004 09/09/08 11:57 a-onl End_of_Run_1425
243003 09/09/08 11:11 a-onl Start_Run_1425,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two arm config test
243002 09/09/08 11:10 a-onl End_of_Run_1424
243001 09/09/08 10:48 a-onl Start_Run_1424,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
243000 09/09/08 10:37 a-onl Start_Run_1423,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242999 09/09/08 10:34 a-onl End_of_Run_1422
242998 09/09/08 09:45 a-onl Start_Run_1422,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242997 09/09/08 09:45 a-onl End_of_Run_1421
242996 09/09/08 09:44 a-onl Start_Run_1421,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242995 09/09/08 09:44 a-onl End_of_Run_1420
242994 09/09/08 09:40 a-onl Start_Run_1420,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242993 09/09/08 09:40 a-onl End_of_Run_1419
242992 09/09/08 09:33 a-onl Start_Run_1419,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242991 09/09/08 09:32 a-onl End_of_Run_1418
242990 09/09/08 09:05 a-onl Start_Run_1418,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242989 09/09/08 08:54 a-onl End_of_Run_1417
Monday
242988 09/08/08 23:00 Jin Huang Replay Dir Built for Transversity
242987 09/08/08 20:41 adev BigBite WireChamber Threshold change!
242986 09/08/08 20:34 a-onl Start_Run_1417,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242985 09/08/08 20:33 a-onl End_of_Run_1416
242984 09/08/08 20:26 a-onl Start_Run_1416,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!! 1600V + 4.5+9+9V
242983 09/08/08 20:25 a-onl End_of_Run_1415
242982 09/08/08 20:20 adev BigBite WireChamber Threshold change!
242981 09/08/08 20:18 a-onl Start_Run_1415,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!! 1600V + 4.5+8+8V
242980 09/08/08 20:17 a-onl End_of_Run_1414
242979 09/08/08 20:15 a-onl Start_Run_1414,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!! 1600V + 4.8+9.0+9.0V
242978 09/08/08 20:13 a-onl End_of_Run_1413
242977 09/08/08 20:11 a-onl Start_Run_1413,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!! 1600V + 3.4 + 5 + 5
242976 09/08/08 20:10 adev BigBite WireChamber Threshold change!
242975 09/08/08 20:07 a-onl End_of_Run_1412
242974 09/08/08 19:59 adev BigBite WireChamber Measured Voltage change!
242973 09/08/08 19:53 a-onl Start_Run_1412,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!! 1600V
242972 09/08/08 19:51 a-onl End_of_Run_1411
242971 09/08/08 19:46 a-onl Start_Run_1411,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!!
242970 09/08/08 19:46 a-onl End_of_Run_1410
242969 09/08/08 19:38 a-onl Start_Run_1410,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!!
242968 09/08/08 19:38 a-onl End_of_Run_1409
242967 09/08/08 19:22 a-onl Start_Run_1409,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test!!!
242966 09/08/08 19:15 a-onl End_of_Run_1408
242965 09/08/08 18:29 a-onl Start_Run_1408,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS tests
242964 09/08/08 18:23 a-onl End_of_Run_1407
242963 09/08/08 18:10 a-onl Start_Run_1407,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS tests
242962 09/08/08 18:08 a-onl End_of_Run_1406
242961 09/08/08 17:37 a-onl Start_Run_1406,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242960 09/08/08 17:13 a-onl End_of_Run_1405
242959 09/08/08 17:04 a-onl Start_Run_1405,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242958 09/08/08 17:03 a-onl End_of_Run_1404
242957 09/08/08 17:02 a-onl Start_Run_1404,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242956 09/08/08 16:15 a-onl Start_Run_1403,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242955 09/08/08 16:13 a-onl End_of_Run_1402
242954 09/08/08 16:00 a-onl Start_Run_1402,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242953 09/08/08 15:59 a-onl End_of_Run_1401
242952 09/08/08 15:47 a-onl Start_Run_1401,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Two Arm configuration tests
242951 09/08/08 15:44 a-onl End_of_Run_1400
242950 09/08/08 15:21 a-onl Start_Run_1400,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Left HRS test for S2M
242949 09/08/08 15:20 a-onl End_of_Run_1399
242948 09/08/08 14:56 a-onl Start_Run_1399,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Left HRS test for S2M
242947 09/08/08 14:41 a-onl End_of_Run_1398
242946 09/08/08 14:35 a-onl Start_Run_1398,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Left HRS test for S2M
242945 09/08/08 14:27 a-onl End_of_Run_1397
242944 09/08/08 13:25 adev BigBite WireChamber HVGUI Start!
242943 09/08/08 11:13 V. Sulkosky Replaced 1877 TDC in ROC 3, Slot 16
242942 09/08/08 10:02 adev Start_Run_20037,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242941 09/08/08 10:01 adev End_of_Run_20037
242940 09/08/08 09:29 Jack Check valve on right argon cylinder cracked
242939 09/08/08 03:43 a-onl Start_Run_1397,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back sci c2 (all 3 chambers) mixed T7 and T8 mixed
242938 09/08/08 03:31 a-onl End_of_Run_1396
242937 09/08/08 03:21 a-onl Start_Run_1396,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test random sci c2 only
242936 09/08/08 03:11 a-onl End_of_Run_1395
242935 09/08/08 03:03 a-onl Start_Run_1395,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test random sci c2+c1+c3 only
242934 09/08/08 03:00 a-onl End_of_Run_1394
242933 09/08/08 02:51 a-onl Start_Run_1394,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci c2+c1+c3 only
242932 09/08/08 02:47 a-onl End_of_Run_1393
242931 09/08/08 02:39 a-onl Start_Run_1393,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci c2+c1+c3 only
242930 09/08/08 02:34 a-onl End_of_Run_1392
242929 09/08/08 02:25 a-onl Start_Run_1392,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci c2+c1 only
242928 09/08/08 02:21 a-onl End_of_Run_1391
242927 09/08/08 02:18 a-onl Start_Run_1391,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci c2 only
242926 09/08/08 02:16 a-onl End_of_Run_1390
242925 09/08/08 01:29 a-onl Start_Run_1390,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back c2 c1+c3 off
242924 09/08/08 01:21 a-onl End_of_Run_1389
242923 09/08/08 00:36 a-onl Start_Run_1389,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back c1+c2 c3 off
242922 09/08/08 00:31 a-onl End_of_Run_1388
Sunday
242921 09/07/08 21:52 a-onl Start_Run_1388,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back c1+c2+c3
242920 09/07/08 21:20 a-onl End_of_Run_1387
242919 09/07/08 21:15 a-onl Start_Run_1387,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back c1+c2
242918 09/07/08 21:10 a-onl End_of_Run_1386
242917 09/07/08 20:44 a-onl Start_Run_1386,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back c1+c2
242916 09/07/08 20:29 a-onl End_of_Run_1385
242915 09/07/08 19:52 a-onl Start_Run_1385,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front+back
242914 09/07/08 19:38 a-onl End_of_Run_1384
242913 09/07/08 19:28 a-onl Start_Run_1384,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci only
242912 09/07/08 19:16 a-onl End_of_Run_1383
242911 09/07/08 19:06 a-onl Start_Run_1383,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci only
242910 09/07/08 18:59 a-onl End_of_Run_1382
242909 09/07/08 18:57 a-onl Start_Run_1382,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci only
242908 09/07/08 18:51 a-onl End_of_Run_1381
242907 09/07/08 18:50 a-onl Start_Run_1381,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test front sci only
242906 09/07/08 18:46 a-onl End_of_Run_1380
242905 09/07/08 18:42 a-onl Start_Run_1380,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test pulser trigger
242904 09/07/08 18:38 a-onl End_of_Run_1379
242903 09/07/08 17:49 a-onl Start_Run_1379,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242902 09/07/08 17:35 a-onl End_of_Run_1378
242901 09/07/08 17:27 a-onl Start_Run_1378,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242900 09/07/08 17:26 a-onl End_of_Run_1377
242899 09/07/08 17:07 a-onl Start_Run_1377,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242898 09/07/08 17:04 a-onl End_of_Run_1376
242897 09/07/08 16:49 a-onl Start_Run_1376,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242896 09/07/08 16:44 a-onl End_of_Run_1375
242895 09/07/08 16:24 a-onl Start_Run_1375,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242894 09/07/08 16:23 a-onl End_of_Run_1374
242893 09/07/08 15:21 a-onl Start_Run_1374,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242892 09/07/08 15:20 a-onl End_of_Run_1373
242891 09/07/08 15:10 a-onl Start_Run_1373,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242890 09/07/08 15:06 a-onl End_of_Run_1372
242889 09/07/08 14:53 a-onl Start_Run_1372,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242888 09/07/08 14:32 a-onl End_of_Run_1371
242887 09/07/08 00:07 a-onl Start_Run_1371,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
242886 09/07/08 00:06 adev BigBite WireChamber Measured Voltage change!
242885 09/07/08 00:04 a-onl End_of_Run_1370
242884 09/07/08 00:01 a-onl Start_Run_1370,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wire chamber test
Saturday
242883 09/06/08 23:56 adev BigBite WireChamber Measured Voltage change!
242882 09/06/08 14:05 a-onl Start_Run_1369,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242881 09/06/08 13:56 a-onl End_of_Run_1368
242880 09/06/08 09:49 a-onl Start_Run_1368,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
Friday
242879 09/05/08 18:08 a-onl End_of_Run_1367
242878 09/05/08 15:52 a-onl Start_Run_1367,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242877 09/05/08 14:47 Jin Huang Target: Spin Signal Recovered
242876 09/05/08 14:23 Jin Huang Target: Spin Signal Temporarily Out
242875 09/05/08 14:00 adev BigBite WireChamber Measured Voltage change!
242874 09/05/08 13:50 adev BigBite WireChamber Measured Voltage change!
242873 09/05/08 13:36 a-onl End_of_Run_1366
242872 09/05/08 11:15 a-onl Start_Run_1366,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=LHRS test
242871 09/05/08 11:09 R. Michaels L-HRS DAQ problems fixed, some issues remain
242870 09/05/08 11:04 a-onl Start_Run_1365,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242869 09/05/08 11:03 a-onl End_of_Run_1364
242868 09/05/08 10:59 a-onl Start_Run_1364,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242867 09/05/08 10:47 a-onl End_of_Run_1362
Thursday
242866 09/04/08 17:22 Kalyan Scaler gates ready
242865 09/04/08 16:55 a-onl Start_Run_1362,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242864 09/04/08 16:53 a-onl End_of_Run_1361
242863 09/04/08 16:32 adev Start_Run_20035,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242862 09/04/08 16:24 adev Start_Run_20034,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242861 09/04/08 16:19 adev Start_Run_20033,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242860 09/04/08 16:14 adev Start_Run_20032,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242859 09/04/08 16:04 adev End_of_Run_20032
242858 09/04/08 15:46 a-onl Start_Run_1361,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242857 09/04/08 15:45 a-onl End_of_Run_1360
242856 09/04/08 15:44 adev Start_Run_20031,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242855 09/04/08 15:38 adev Start_Run_20030,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242854 09/04/08 15:31 a-onl Start_Run_1360,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242853 09/04/08 15:31 a-onl End_of_Run_1359
242852 09/04/08 15:17 a-onl Start_Run_1359,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242851 09/04/08 15:16 a-onl End_of_Run_1358
242850 09/04/08 15:13 a-onl Start_Run_1358,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242849 09/04/08 15:11 a-onl End_of_Run_1357
242848 09/04/08 15:04 adev Start_Run_20028,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242847 09/04/08 14:03 a-onl Start_Run_1357,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Wire chamber test
242846 09/04/08 13:57 a-onl Start_Run_1356,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Left HRS test
242845 09/04/08 13:29 adev Start_Run_20026,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242844 09/04/08 13:21 adev Start_Run_20025,Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=nothing.
242843 09/04/08 11:15 a-onl End_of_Run_1355
Wednesday
242842 09/03/08 19:12 adev BigBite WireChamber HVGUI Start!
242841 09/03/08 19:01 a-onl Start_Run_1355,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242840 09/03/08 19:00 a-onl End_of_Run_1354
242839 09/03/08 18:21 a-onl Start_Run_1354,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242838 09/03/08 18:10 a-onl End_of_Run_1353
242837 09/03/08 17:55 a-onl Start_Run_1353,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242836 09/03/08 17:10 Chiranjib HV back to the original values
242835 09/03/08 17:08 a-onl End_of_Run_1352
242834 09/03/08 17:07 Chiranjib NO ADC histograms
242833 09/03/08 17:03 a-onl Start_Run_1352,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242832 09/03/08 17:02 a-onl End_of_Run_1351
242831 09/03/08 16:50 a-onl Start_Run_1351,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242830 09/03/08 16:49 a-onl End_of_Run_1350
242829 09/03/08 16:44 Chiranjib HV change
242828 09/03/08 16:31 a-onl Start_Run_1350,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242827 09/03/08 16:28 a-onl End_of_Run_1349
242826 09/03/08 16:26 Jin Huang Target: Simulated Spin Signal to 30s/flip
242825 09/03/08 16:25 a-onl Start_Run_1349,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242824 09/03/08 14:36 a-onl Start_Run_1348,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242823 09/03/08 13:29 a-onl End_of_Run_1347
242822 09/03/08 12:08 R. Michaels L-HRS scalers ready (but waiting for target state)
242821 09/03/08 11:51 a-onl Start_Run_1347,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242820 09/03/08 11:12 a-onl End_of_Run_1346
242819 09/03/08 11:10 a-onl Start_Run_1346,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
Tuesday
242818 09/02/08 23:47 Jin Huang Target: Spin Signal is Back
242817 09/02/08 23:30 a-onl Start_Run_1345,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242816 09/02/08 23:27 a-onl End_of_Run_1344
242815 09/02/08 22:52 a-onl Start_Run_1344,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242814 09/02/08 22:52 a-onl End_of_Run_1343
242813 09/02/08 22:19 a-onl Start_Run_1343,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242812 09/02/08 22:07 a-onl End_of_Run_1342
242811 09/02/08 22:06 a-onl Start_Run_1342,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242810 09/02/08 18:49 a-onl Start_Run_1341,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242809 09/02/08 18:47 a-onl End_of_Run_1339
242808 09/02/08 18:21 a-onl Start_Run_1339,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test kalyan spilled coffee on his computation notebook
242807 09/02/08 18:20 a-onl End_of_Run_1338
242806 09/02/08 18:18 a-onl Start_Run_1338,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242805 09/02/08 18:16 a-onl End_of_Run_1337
242804 09/02/08 17:54 a-onl Start_Run_1337,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242803 09/02/08 17:48 a-onl End_of_Run_1336
242802 09/02/08 17:36 a-onl Start_Run_1336,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242801 09/02/08 17:35 a-onl End_of_Run_1335
242800 09/02/08 17:30 a-onl Start_Run_1335,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242799 09/02/08 17:27 a-onl Start_Run_1334,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242798 09/02/08 17:27 a-onl End_of_Run_1334
242797 09/02/08 17:17 Moffit BBDAQ: ROC5 changes. Removed software limit on pulser prescale.
242796 09/02/08 17:12 a-onl End_of_Run_1332
242795 09/02/08 17:10 a-onl End_of_Run_1331
242794 09/02/08 17:03 a-onl Start_Run_1331,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242793 09/02/08 16:54 a-onl Start_Run_1330,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
242792 09/02/08 15:31 fansler Q2/Q3 LN2 readbacks
Monday
242791 09/01/08 17:39 a-onl Start_Run_1329,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=on,leftarm_p=0.6955,leftarm_theta=53,leftarm_colli=out,bbarm_i=700,bbarm_theta=35,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=wirechamber test
Earlier months at hallaweb.jlab.org/adaq (archive). The HALOG was generated by version HA1.41
If you have any comments or problems, please contact:
Robert Michaels
rom@jlab.org
(757) 269-7410