Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:47:24 on October 4, 2008

    Entry number 243498

    keyword=Start_Run_1658,Run_type=Test,target_type=Empty,beam_e0=1.192,beam_raster=off,leftarm_p=0.6955,leftarm_theta=53,leftarm_sieve=,bbarm_i=0,bbarm_theta=35,bbarm_sieve=,bbarm_zoff=0,comment_text=
    Run Timestamp:       Sat Oct  4 14:46:26 EDT 2008
    Beginning-of-run EPICS data for Run Number 1658 at Sat Oct 4 14:46:35 EDT 2008
    
    
    
    Run_type=Test
    target_type=Empty
    beam_e0=1.192
    beam_raster=off
    leftarm_p=0.6955
    leftarm_theta=53
    leftarm_sieve=
    bbarm_i=0
    bbarm_theta=35
    bbarm_sieve=
    bbarm_zoff=0
    comment_text=
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)	
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=1,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65335,ps7=65335,ps8=1 
    
    
    Left Arm Q1 momentum : 0.223491
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.014593
    Left Arm Q2 power supply current : -0.000284529
    Left Arm Q2 momentum : -6.60773e-07
    Left Arm Q2 gauss meter : -8.81e-05
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.40455
    Left Arm D1 momentum : 0.0157448
    Left Arm D1 NMR : 0.989647
    Left Arm Q3 power supply current : -5.64232e-05
    Left Arm Q3 momentum : -1.41724e-07
    Left Arm Q3 gauss meter : 0.00151129
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.005656
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : -0.002831
    -----
    Left Arm Top VDC Current : -1.61133
    Left Arm Bottom VDC Current : 4.58984
    Left Arm Top VDC voltage : 3.98975
    Left Arm Bottom VDC voltage : 3.99707
    -----
    RICH Vmon 16 :
    RICH Imon 16 :
    RICH Vmon 17 :
    RICH Imon 17 :
    RICH Radiator Oxygen : -1.95312
    RICH Radiator Moisture : 243.652
    RICH Radiator Pressure : 13.6987
    RICH Condensor temperature : -14.3086
    RICH Gas Oxygen : -1.17188
    RICH Gas Moisture : -1.17188
    RICH Argon Flow : 0.195312
    RICH Methane Flow : 1549.51
    RICH A Volts : 7.96045
    RICH B Volts : 4.44922
    -----
    Average current of the two cavities : 0.0295556
    Current on Unser monitor : -7.25789
    Current on Upstream bcm : 0.0433775
    Current on Downstream bcm : 0.0157336
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.00360757
    Hall C Current : 0.379265
    Hall A momentum (Tiefenbach) (HALLA:p) : 2398.71
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 2399.64
    Hall A energy (halla_MeV) : 2398.71
    Hall C energy (hallc_MeV) : 5896.91
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 599383
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 2
    Raster Y width : 2
    -----
    HacL_HPE1313A:0_Ch58 : -0.220703
    HacL_HPE1313A:0_Ch55 : 25.0977
    HacL_HPE1313A:0_Ch54 : 0.0927734
    Left Arm Angle Floor Angle : 0
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.89648
    Left VDC -DISC LVL Bottom : 3.95947
    Left VDC -DISC LVL Voltage1 : 4.96924
    Left VDC -DISC LVL Voltage2 : -5.06006
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 98
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    RTD1 (upstream) : 0
    RTD2 : 0
    RTD3 : 0
    RTD4 : 0
    RTD5 (downstream) : 0
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) : 0
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell : 0
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -23.46
    Oven Air Flow : HacOMEGA_RTD --- Invalid channel name
    Over Heater Temperature : HacDP41_READ --- Invalid channel name
    -----
    HaGenTargBrake : disabled
    HaGenTargBrake : disabled
    HacOMEGA_AL1 : HacOMEGA_AL1 --- Invalid channel name
    HacOMEGA_READ :
    HacOMEGA_SP1 :
    HacOMEGA_PROP1 :
    HacOMEGA_RST1 :
    HacOMEGA_RATE :
    pol3heSmallCoilCurrent :
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR :
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR :
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 :
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP :
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP :
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0
    SLI vert. size mm : 0
    SLI y position : 0
    -----
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1890.6
    S2 Slot0 ch1 Left : -1884.9
    S2 Slot0 ch2 Left : -2200.7
    S2 Slot0 ch3 Left : -2031.1
    S2 Slot0 ch4 Left : -2122.8
    S2 Slot0 ch5 Left : -1816.6
    S2 Slot0 ch6 Left : -2017.9
    S2 Slot0 ch7 Left : -1931.3
    S2 Slot0 ch8 Left : -1901.5
    S2 Slot0 ch9 Left : -2079.9
    S2 Slot0 ch10 Left : -2200.8
    S2 Slot0 ch11 Left : -1997.6
    S2 Slot13 ch0 Left : -2166.4
    S2 Slot13 ch1 Left :
    S2 Slot13 ch2 Left : -1926.4
    S2 Slot13 ch3 Left : -1726.3
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1776.3
    S2 Slot12 ch1 Right : -1803.6
    S2 Slot12 ch2 Right : -1991.1
    S2 Slot12 ch3 Right : -1868.9
    S2 Slot12 ch4 Right : -2021
    S2 Slot12 ch5 Right : -1945.8
    S2 Slot12 ch6 Right : -1983.7
    S2 Slot12 ch7 Right : -1953.7
    S2 Slot12 ch8 Right : -2050.7
    S2 Slot12 ch9 Right : -2010.7
    S2 Slot12 ch10 Right : -2089.3
    S2 Slot12 ch11 Right : -1738
    S2 Slot13 ch4 Right : -1791.3
    S2 Slot13 ch5 Right : -1891.3
    S2 Slot13 ch6 Right : -1859.5
    S2 Slot13 ch7 Right : -1871.6
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.2
    S1 Slot1 ch1 : -1809.8
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1820
    S1 Slot1 ch4 : -1700.7
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.9
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1799.2
    S1 Slot1 ch11 : -1709.1
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -22.5
    GCER Slot2 ch1 : -17.6
    GCER Slot2 ch2 : -23
    GCER Slot2 ch3 : -22.2
    GCER Slot2 ch4 : -21
    GCER Slot2 ch5 : -24.2
    GCER Slot2 ch6 : -20.2
    GCER Slot2 ch7 : -22
    GCER Slot2 ch8 : -24.6
    GCER Slot2 ch9 : -22.7
    GCER Slot2 ch10 : -20.3
    GCER Slot2 ch11 : -22.1
    -----
    Left A1 Cerenkov HV
    A1 CER Slot14 ch0 : 2480.6
    A1 CER Slot14 ch1 : 2525.3
    A1 CER Slot14 ch2 : 2425.5
    A1 CER Slot14 ch3 : 2450.7
    A1 CER Slot14 ch4 : 2400.6
    A1 CER Slot14 ch5 : 2088.2
    A1 CER Slot14 ch6 : 2521.1
    A1 CER Slot14 ch7 : 2606.5
    A1 CER Slot14 ch8 : 2455.3
    A1 CER Slot14 ch9 : 2505.9
    A1 CER Slot14 ch10 : 2470.9
    A1 CER Slot14 ch11 : 2220.6
    -----
    A1 CER Slot15 ch0 : 2490.2
    A1 CER Slot15 ch1 : 2434.5
    A1 CER Slot15 ch2 : 2405
    A1 CER Slot15 ch3 : 2394.6
    A1 CER Slot15 ch4 : 2500.8
    A1 CER Slot15 ch5 : 2360.6
    A1 CER Slot15 ch6 : 2460.3
    A1 CER Slot15 ch7 : 2465.7
    A1 CER Slot15 ch8 : 2484.9
    A1 CER Slot15 ch9 : 2430.8
    A1 CER Slot15 ch10 : 2361.1
    A1 CER Slot15 ch11 : 2155.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -980.5
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -831.8
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750
    PRL1 Slot4 ch3 : -895.1
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -835.2
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -1071.9
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1040.4
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -17.3
    PRL1 Slot5 ch11 : -26.4
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -901.2
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -891
    PRL2 Slot11 ch7 : -1051.2
    PRL2 Slot11 ch8 : -956.4
    PRL2 Slot11 ch9 : -901
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1339  -1503 
      2 :  -1336  -1418 
      3 :  -1244  -1476 
      4 :  -1588  -1593 
      5 :  -1410  -1273 
      6 :  -1482  -1444 
      7 :  -1284  -1196 
      8 :  -1345  -1452 
      9 :  -1194  -1595 
     10 :  -1607  -1296 
     11 :  -1536  -1539 
     12 :  -1330  -1554 
     13 :  -1626  -1559 
     14 :  -1217  -1544 
     15 :  -1436  -1588 
     16 :  -1405  -1324 
     17 :  -1139  -1585 
     18 :  -1466  -1288 
     19 :  -1381  -1417 
     20 :  -1397  -1599 
     21 :  -1471  -1500 
     22 :  -1531  -1680 
     23 :  -1583  -1459 
     24 :  -1509  -1270 
    # Map  BB_DE  Measured Current
      1 :   -136   -168 
      2 :   -142   -156 
      3 :   -132   -164 
      4 :   -166   -176 
      5 :   -150   -136 
      6 :   -162   -158 
      7 :   -141   -129 
      8 :   -143   -156 
      9 :   -126   -176 
     10 :   -170   -140 
     11 :   -162   -166 
     12 :   -146   -172 
     13 :   -177   -163 
     14 :   -132   -171 
     15 :   -154   -173 
     16 :   -152   -139 
     17 :   -122   -165 
     18 :   -163   -136 
     19 :   -153   -150 
     20 :   -155   -176 
     21 :   -159   -158 
     22 :   -174   -157 
     23 :   -170   -156 
     24 :   -167   -136 
    # Map  BB_E  Measured Voltage
      1 :  -1523  -1578 
      2 :  -1623  -1299 
      3 :  -1316  -1384 
      4 :  -1235  -1271 
      5 :  -1361  -1608 
      6 :  -1437  -1548 
      7 :  -1602  -1311 
      8 :  -1346  -1509 
      9 :  -1340  -1545 
     10 :  -1300  -1265 
     11 :  -1681  -1537 
     12 :  -1286  -1584 
     13 :  -1676  -1419 
     14 :  -1289  -1459 
     15 :  -1641  -1291 
     16 :  -1310  -1588 
     17 :  -1532  -1430 
     18 :  -1066  -1290 
     19 :  -1379  -1648 
     20 :  -1558  -1500 
     21 :  -1332  -1586 
     22 :  -1578  -1176 
     23 :  -1419  -1251 
     24 :  -1196    -24 
    # Map  BB_E  Measured Current
      1 :   -160   -168 
      2 :   -175   -138 
      3 :   -139   -150 
      4 :   -136   -138 
      5 :   -148   -171 
      6 :   -152   -170 
      7 :   -170   -142 
      8 :   -145   -164 
      9 :   -141   -164 
     10 :   -137   -131 
     11 :   -177   -161 
     12 :   -136   -168 
     13 :   -180   -145 
     14 :   -135   -150 
     15 :   -180   -134 
     16 :   -142   -152 
     17 :   -165   -157 
     18 :   -116   -131 
     19 :   -145   -166 
     20 :   -165   -164 
     21 :   -140   -163 
     22 :   -167   -121 
     23 :   -149   -132 
     24 :   -126     -1 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1176 
      2 :  -1154 
      3 :  -1174 
      4 :  -1159 
      5 :  -1190 
      6 :  -1201 
      7 :  -1267 
      8 :  -1126 
      9 :  -1196 
     10 :  -1274 
     11 :  -1306 
     12 :  -1176 
     13 :  -1293 
    # Map  BB_SC_R  Measured Current
      1 :   -444 
      2 :   -437 
      3 :   -444 
      4 :   -436 
      5 :   -451 
      6 :   -455 
      7 :   -480 
      8 :   -424 
      9 :   -462 
     10 :   -483 
     11 :   -495 
     12 :   -443 
     13 :   -489 
    # Map  BB_DC  Measured Voltage
      1 :  -1600  -1600  -1600  -1600 
      2 :  -1601  -1600  -1600  -1600 
      3 :  -1600  -1601  -1601  -1600 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :   -868 
      2 :   -832 
      3 :   -846 
      4 :   -848 
      5 :   -860 
      6 :   -855 
      7 :   -840 
      8 :   -846 
      9 :   -903 
     10 :   -901 
     11 :   -859 
     12 :   -853 
     13 :   -860 
     14 :   -862 
     15 :   -833 
     16 :   -918 
     17 :   -816 
     18 :   -845 
     19 :   -852 
     20 :   -838 
     21 :   -840 
     22 :   -818 
     23 :   -837 
     24 :   -826 
     25 :   -789 
     26 :   -858 
     27 :   -865 
    # Map  BB_PS_R  Measured Current
      1 :   -223 
      2 :   -212 
      3 :   -215 
      4 :   -216 
      5 :   -220 
      6 :   -219 
      7 :   -214 
      8 :   -215 
      9 :   -231 
     10 :   -230 
     11 :   -219 
     12 :   -218 
     13 :   -220 
     14 :   -221 
     15 :   -214 
     16 :   -232 
     17 :   -208 
     18 :   -216 
     19 :   -216 
     20 :   -215 
     21 :   -216 
     22 :   -209 
     23 :   -214 
     24 :   -212 
     25 :   -203 
     26 :   -220 
     27 :   -221 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1233 
      2 :  -1271 
      3 :  -1214 
      4 :  -1150 
      5 :  -1162 
      6 :  -1268 
      7 :  -1316 
      8 :  -1122 
      9 :  -1201 
     10 :  -1243 
     11 :  -1317 
     12 :  -1230 
     13 :  -1242 
    # Map  BB_SC_L  Measured Current
      1 :   -446 
      2 :   -423 
      3 :   -454 
      4 :   -396 
      5 :   -390 
      6 :   -456 
      7 :   -465 
      8 :   -402 
      9 :   -412 
     10 :   -448 
     11 :   -486 
     12 :   -463 
     13 :   -469 
    # Map  BB_CER  Measured Voltage
      1 :      6      6 
      2 :      4      4 
      3 :      5      5 
      4 :      4      6 
      5 :      4      4 
      6 :      6      5 
      7 :      4      5 
      8 :      4      6 
      9 :      5      5 
     10 :      5      6 
    # Map  BB_CER  Measured Current
      1 :      2      1 
      2 :      2      2 
      3 :      2      3 
      4 :      2      2 
      5 :      1      2 
      6 :      2      2 
      7 :      2     -1 
      8 :      2      2 
      9 :      1      1 
     10 :      2      3 
    # Map  BB_PS_L  Measured Voltage
      1 :   -931 
      2 :   -916 
      3 :   -860 
      4 :   -938 
      5 :   -904 
      6 :   -917 
      7 :   -905 
      8 :   -865 
      9 :   -920 
     10 :   -945 
     11 :   -919 
     12 :   -926 
     13 :   -923 
     14 :   -913 
     15 :   -949 
     16 :   -918 
     17 :   -862 
     18 :   -880 
     19 :   -814 
     20 :   -846 
     21 :   -823 
     22 :   -819 
     23 :   -816 
     24 :   -855 
     25 :   -857 
     26 :   -823 
     27 :   -840 
    # Map  BB_PS_L  Measured Current
      1 :   -240 
      2 :   -235 
      3 :   -220 
      4 :   -240 
      5 :   -233 
      6 :   -237 
      7 :   -230 
      8 :   -220 
      9 :   -236 
     10 :   -242 
     11 :   -236 
     12 :   -238 
     13 :   -236 
     14 :   -234 
     15 :   -243 
     16 :   -232 
     17 :   -220 
     18 :   -226 
     19 :   -211 
     20 :   -214 
     21 :   -212 
     22 :   -210 
     23 :   -207 
     24 :   -220 
     25 :   -220 
     26 :   -211 
     27 :   -216 
    # Map  BB_SH  Measured Voltage
      1 :  -1339  -1336  -1244  -1588  -1634  -1763  -1325 
      2 :  -1410  -1482  -1284  -1473  -1385  -1324  -1589 
      3 :  -1345  -1194  -1607  -1536  -1529  -1556  -1524 
      4 :  -1330  -1626  -1217  -1624  -1376  -1842  -1593 
      5 :  -1436  -1405  -1139  -1466  -1502  -1426  -1493 
      6 :  -1381  -1397  -1471  -1632  -1696  -1452  -1334 
      7 :  -1531  -1583  -1509  -1503  -1656  -1570  -1632 
      8 :  -1418  -1476  -1593  -1088  -1586  -1700  -1386 
      9 :  -1273  -1444  -1196  -1452  -1524  -1280  -1495 
     10 :  -1595  -1296  -1539  -1196  -1276  -1302  -1520 
     11 :  -1554  -1559  -1544  -1588  -1409  -1426  -1256 
     12 :  -1324  -1585  -1288  -1477  -1404  -1556  -1616 
     13 :  -1417  -1599  -1500  -1680  -1250  -1460  -1614 
     14 :  -1459  -1270  -1523  -1304  -1545  -1555  -1577 
     15 :  -1623  -1316  -1235  -1361  -1534  -1440  -1470 
     16 :  -1437  -1602  -1346  -1669  -1471  -1604  -1228 
     17 :  -1340  -1300  -1681  -1286  -1465  -1536  -1592 
     18 :  -1676  -1289  -1641  -1175  -1673  -1533  -1450 
     19 :  -1310  -1532  -1066  -1379  -1430  -1687  -1389 
     20 :  -1558  -1332  -1578  -1302  -1542  -1324  -1507 
     21 :  -1419  -1196  -1578  -1299  -1594  -1426  -1270 
     22 :  -1384  -1271  -1608  -1363  -1454  -1534  -1454 
     23 :  -1548  -1311  -1509  -1545  -1662  -1192  -1386 
     24 :  -1265  -1537  -1584  -1465  -1332  -1504  -1418 
     25 :  -1419  -1459  -1291  -1588  -1368  -1293  -1628 
     26 :  -1430  -1290  -1648  -1318  -1272  -1596  -1612 
     27 :  -1500  -1586  -1176  -1251  -1314  -1463  -1478 
    # Map  BB_SH  Measured Current
      1 :   -136   -141   -132   -170   -175   -188   -144 
      2 :   -149   -161   -141   -154   -147   -137   -174 
      3 :   -143   -128   -169   -165   -162   -165   -161 
      4 :   -145   -178   -132   -168   -148   -186   -165 
      5 :   -155   -150   -123   -162   -142   -150   -155 
      6 :   -153   -160   -158   -170   -177   -147   -146 
      7 :   -172   -169   -166   -169   -175   -162   -172 
      8 :   -159   -163   -177   -117   -166   -189   -146 
      9 :   -137   -160   -128   -155   -166   -138   -158 
     10 :   -175   -139   -165   -131   -138   -137   -160 
     11 :   -172   -165   -168   -174   -153   -152   -134 
     12 :   -139   -167   -136   -155   -148   -166   -172 
     13 :   -149   -178   -158   -158   -132   -154   -169 
     14 :   -155   -135   -160   -138   -165   -169   -164 
     15 :   -175   -140   -132   -148   -162   -158   -156 
     16 :   -152   -172   -141   -176   -154   -172   -128 
     17 :   -141   -137   -176   -139   -150   -162   -170 
     18 :   -180   -135   -180   -127   -184   -167   -152 
     19 :   -142   -165   -116   -145   -154   -179   -147 
     20 :   -165   -140   -167   -140   -161   -140   -161 
     21 :   -149   -126   -168   -138   -169   -150   -135 
     22 :   -150   -138   -171   -144   -156   -164   -155 
     23 :   -170   -142   -164   -164   -178   -130   -147 
     24 :   -131   -161   -168   -161   -140   -160   -154 
     25 :   -145   -150   -134   -152   -144   -137   -173 
     26 :   -157   -131   -166   -143   -135   -172   -173 
     27 :   -164   -163   -121   -132   -137   -156   -158 
    Threshold for 'mwdc_front' is +3.503 V  (2526)
    Threshold for 'mwdc_middle' is +3.503 V  (2526)
    Threshold for 'mwdc_back' is +3.503 V  (2526)
    Threshold for 'BB_Sh' is -0.040 V  (1997)
    Threshold for 'BB_PSh' is -0.040 V  (1997)
    Threshold for 'BB_Cer' is -0.010 V  (2048)