Privacy and Security Notice

Start_Run_3982,Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Vertical,targetpol_pol=65.2,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production with new cell Maureen at 12uA, happex run#30470


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:44:32 on November 27, 2008

    Entry number 251073

    keyword=Start_Run_3982,Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Vertical,targetpol_pol=65.2,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production with new cell Maureen at 12uA, happex run#30470
    Run Timestamp:       Thu Nov 27 19:43:57 EST 2008
    Beginning-of-run EPICS data for Run Number 3982 at Thu Nov 27 19:44:04 EST 2008
    
    
    
    Run_type=Production
    target_type=Polarized 3He
    targetpol_poldir=Vertical
    targetpol_pol=65.2
    beam_e0=5.892
    beam_raster=on
    leftarm_p=2.35
    leftarm_theta=16
    leftarm_sieve=out
    bbarm_i=710
    bbarm_theta=30
    bbarm_sieve=out
    bbarm_zoff=0
    comment_text=Production with new cell Maureen at 12uA, happex run#30470
    
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Total shower
    ; T2 = BigBite Total shower + Cerenkov overlap
    ; T3 = L-HRS Singles (S1.and.S2)	
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = BigBite Total shower 2nd trigger
    ; T7 = BigBite Cerenkov onyl
    ; T8 = 1024 Hz pulser
    ; T9 = BigBite cosmics(front-back)
    ; T10 = BigBite cosmics(top-down)
    ; String should be one line, no spaces, ending in carriage return
    ; WE WANT AT LEAST 10HZ OF T8 IN EVERY RUN
    ;production
    ps1=2100,ps2=16777215,ps3=27,ps4=16777215,ps5=1,ps6=100,ps7=65535,ps8=100
    
    
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14992
    Left Arm Q2 power supply current : 1011.98
    Left Arm Q2 momentum : 2.35016
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.503
    Left Arm D1 momentum : 2.35005
    Left Arm D1 NMR : 0.869669
    Left Arm Q3 power supply current : 935.548
    Left Arm Q3 momentum : 2.34992
    Left Arm Q3 gauss meter : -0.47198
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -0.8386
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Left Arm Top VDC Current : 5.27344
    Left Arm Bottom VDC Current : -0.537109
    Left Arm Top VDC voltage : 4.00879
    Left Arm Bottom VDC voltage : 4.00586
    -----
    RICH Vmon 16 : 2204.4
    RICH Imon 16 : 0.04
    RICH Vmon 17 : 201
    RICH Imon 17 : 0.01
    RICH Radiator Oxygen : -0.878906
    RICH Radiator Moisture : 332.422
    RICH Radiator Pressure : 9.86328
    RICH Condensor temperature : -9.42578
    RICH Gas Oxygen : 3.71094
    RICH Gas Moisture : 13.0859
    RICH Argon Flow : 0.683594
    RICH Methane Flow : 1547.95
    RICH A Volts : 3.80762
    RICH B Volts : 3.88037
    -----
    Average current of the two cavities : 12.0565
    Current on Unser monitor : 4.69701
    Current on Upstream bcm : 12.0414
    Current on Downstream bcm : 12.0716
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 12.1414
    Hall C Current : 2.98163
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.08
    Hall A momentum orbit correction (dpp) : 3.8903e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.08
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 3.78229
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 3
    Raster Y width : 4
    -----
    HacL_HPE1313A:0_Ch58 : -0.181641
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : 0.0810547
    Left Arm Angle Floor Angle : 16
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89697
    Left VDC -DISC LVL Bottom : 3.96191
    Left VDC -DISC LVL Voltage1 : 4.97314
    Left VDC -DISC LVL Voltage2 : -5.06299
    -----
    IPM1C12.XPOS : 0.00575837
    IPM1C12.YPOS : 0.305726
    IPM1H04A.XPOS : 0.190165
    IPM1H04A.YPOS : 1.73504
    IPM1H04B.XPOS : -1.51015
    IPM1H04B.YPOS : 1.19537
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 20.72
    Laser attenuation Hall A : 168
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    RTD1 (upstream) : 42.1973
    RTD2 : 58.9844
    RTD3 : 160.381
    RTD4 : 71.084
    RTD5 (downstream) : 41.3477
    RTD6 (pump cell up) : 240.352
    RTD7 (pump cell down) : 247.207
    HacAi_hpchan7: Temp at Ref. Cell : 39.4727
    HacAi_hpchan8: Temp at Ref. Cell : 55.7617
    HacAi_hpchan9: Temp at Ref. Cell : 38.75
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.9
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.8
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0021
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -0.359
    DDM45_2disp1_read : 0.329
    DDM45_3disp1_read : 0.329
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 262
    haPolHe3_Flip_Count : 88
    haPolHe3_EPR_ID : 11261016
    haPolHe3_EPR_POL : 64.0811
    haPolHe3_Last_Flip_Start : 19:30:22 11/27/2008it!
    haPolHe3_Last_Flip_End : 19:30:27 11/27/2008it!
    haPolHe3_FLIP_NMR_PHASE : 181.496
    haPolHe3_FLIP_NMR_Mag : 11.8304
    haPolHe3_FLIP_NMR_Pol : 61.9301
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0970738
    SLI Energy spread *10^5 : 2.42684
    SLI x position : 1.49068
    SLI vert. size mm : 0.0822906
    SLI y position : 1.63005
    -----
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1889.9
    S2 Slot0 ch1 Left : -1872
    S2 Slot0 ch2 Left : -2240.2
    S2 Slot0 ch3 Left : -2045.7
    S2 Slot0 ch4 Left : -2124.3
    S2 Slot0 ch5 Left : -1828.9
    S2 Slot0 ch6 Left : -2017.9
    S2 Slot0 ch7 Left : -1932.1
    S2 Slot0 ch8 Left : -1871.2
    S2 Slot0 ch9 Left : -2055.6
    S2 Slot0 ch10 Left : -2189.9
    S2 Slot0 ch11 Left : -2010.6
    S2 Slot13 ch0 Left : -2190.9
    S2 Slot13 ch1 Left : -2166.3
    S2 Slot13 ch2 Left : -1897.3
    S2 Slot13 ch3 Left : -1743.2
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1767.2
    S2 Slot12 ch1 Right : -1781.5
    S2 Slot12 ch2 Right : -1968.6
    S2 Slot12 ch3 Right : -1847.5
    S2 Slot12 ch4 Right : -1984.6
    S2 Slot12 ch5 Right : -1903.7
    S2 Slot12 ch6 Right : -1959.1
    S2 Slot12 ch7 Right : -1898.8
    S2 Slot12 ch8 Right : -2014.9
    S2 Slot12 ch9 Right : -1988.7
    S2 Slot12 ch10 Right : -2040.6
    S2 Slot12 ch11 Right : -1709.4
    S2 Slot13 ch4 Right : -1756.1
    S2 Slot13 ch5 Right : -1879.1
    S2 Slot13 ch6 Right : -1858.7
    S2 Slot13 ch7 Right : -1833.5
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1800.4
    S1 Slot1 ch1 : -1797.6
    S1 Slot1 ch2 : -1807.8
    S1 Slot1 ch3 : -1840.8
    S1 Slot1 ch4 : -1718.2
    S1 Slot1 ch5 : -1890.6
    S1 Slot1 ch6 : -1946.8
    S1 Slot1 ch7 : -1720.7
    S1 Slot1 ch8 : -1954.9
    S1 Slot1 ch9 : -1772.3
    S1 Slot1 ch10 : -1824.4
    S1 Slot1 ch11 : -1743.7
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1521.5
    GCER Slot2 ch1 : -1452.3
    GCER Slot2 ch2 : -1515.8
    GCER Slot2 ch3 : -1431
    GCER Slot2 ch4 : -1781.1
    GCER Slot2 ch5 : -1984.4
    GCER Slot2 ch6 : -1663.4
    GCER Slot2 ch7 : -1724.8
    GCER Slot2 ch8 : -1993.8
    GCER Slot2 ch9 : -1538.1
    GCER Slot2 ch10 : -14.2
    GCER Slot2 ch11 : -22.8
    -----
    Left A1 Cerenkov HV
    A1 CER Slot14 ch0 : 2490.5
    A1 CER Slot14 ch1 : 2530.6
    A1 CER Slot14 ch2 : 2430
    A1 CER Slot14 ch3 : 2456.1
    A1 CER Slot14 ch4 : 2405.1
    A1 CER Slot14 ch5 : 2098.1
    A1 CER Slot14 ch6 : 2526.4
    A1 CER Slot14 ch7 : 2611.1
    A1 CER Slot14 ch8 : 2466
    A1 CER Slot14 ch9 : 2511.2
    A1 CER Slot14 ch10 : 2476.2
    A1 CER Slot14 ch11 : 2320.6
    -----
    A1 CER Slot15 ch0 : 2495.6
    A1 CER Slot15 ch1 : 2439.8
    A1 CER Slot15 ch2 : 2405
    A1 CER Slot15 ch3 : 2409.9
    A1 CER Slot15 ch4 : 2506.2
    A1 CER Slot15 ch5 : 2366
    A1 CER Slot15 ch6 : 2464.9
    A1 CER Slot15 ch7 : 2475.6
    A1 CER Slot15 ch8 : 2490.2
    A1 CER Slot15 ch9 : 2435.4
    A1 CER Slot15 ch10 : 2366.5
    A1 CER Slot15 ch11 : 2170.9
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -900.3
    PRL1 Slot3 ch1 : -815.1
    PRL1 Slot3 ch2 : -931.9
    PRL1 Slot3 ch3 : -985.8
    PRL1 Slot3 ch4 : -787.1
    PRL1 Slot3 ch5 : -886.9
    PRL1 Slot3 ch6 : -1095
    PRL1 Slot3 ch7 : -1012.6
    PRL1 Slot3 ch8 : -834.9
    PRL1 Slot3 ch9 : -816.1
    PRL1 Slot3 ch10 : -886.6
    PRL1 Slot3 ch11 : -809.5
    PRL1 Slot4 ch0 : -901.1
    PRL1 Slot4 ch1 : -931.4
    PRL1 Slot4 ch2 : -768.2
    PRL1 Slot4 ch3 : -942
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -824.3
    PRL1 Slot4 ch6 : -837.5
    PRL1 Slot4 ch7 : -829.5
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -1039.2
    PRL1 Slot4 ch10 : -1079.5
    PRL1 Slot4 ch11 : -877.4
    PRL1 Slot5 ch0 : -1075.5
    PRL1 Slot5 ch1 : -902.4
    PRL1 Slot5 ch2 : -945.2
    PRL1 Slot5 ch3 : -764.9
    PRL1 Slot5 ch4 : -917.5
    PRL1 Slot5 ch5 : -823.3
    PRL1 Slot5 ch6 : -838.7
    PRL1 Slot5 ch7 : -891.8
    PRL1 Slot5 ch8 : -786.7
    PRL1 Slot5 ch9 : -840.6
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -900.6
    PRL2 Slot9 ch1 : -918.8
    PRL2 Slot9 ch2 : -794.8
    PRL2 Slot9 ch3 : -883.7
    PRL2 Slot9 ch4 : -811.6
    PRL2 Slot9 ch5 : -930.8
    PRL2 Slot9 ch6 : -852.2
    PRL2 Slot9 ch7 : -886.7
    PRL2 Slot9 ch8 : -827.5
    PRL2 Slot9 ch9 : -777.6
    PRL2 Slot9 ch10 : -834
    PRL2 Slot9 ch11 : -842.2
    PRL2 Slot10 ch0 : -754.2
    PRL2 Slot10 ch1 : -798.9
    PRL2 Slot10 ch2 : -861.1
    PRL2 Slot10 ch3 : -881.2
    PRL2 Slot10 ch4 : -969.2
    PRL2 Slot10 ch5 : -805.9
    PRL2 Slot10 ch6 : -796.1
    PRL2 Slot10 ch7 : -821.8
    PRL2 Slot10 ch8 : -773
    PRL2 Slot10 ch9 : -721.1
    PRL2 Slot10 ch10 : -901.8
    PRL2 Slot10 ch11 : -795.7
    PRL2 Slot11 ch0 : -989.2
    PRL2 Slot11 ch1 : -922.7
    PRL2 Slot11 ch2 : -863.6
    PRL2 Slot11 ch3 : -1079.1
    PRL2 Slot11 ch4 : -1053.3
    PRL2 Slot11 ch5 : -805.4
    PRL2 Slot11 ch6 : -858.9
    PRL2 Slot11 ch7 : -1007.6
    PRL2 Slot11 ch8 : -903.7
    PRL2 Slot11 ch9 : -863.5
    PRL2 Slot11 ch10 : -3.7
    PRL2 Slot11 ch11 : -11.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1325  -1518 
      2 :  -1298  -1407 
      3 :  -1284  -1532 
      4 :  -1585  -1611 
      5 :  -1363  -1381 
      6 :  -1524  -1494 
      7 :  -1274  -1232 
      8 :  -1323  -1420 
      9 :  -1151  -1771 
     10 :  -1654  -1181 
     11 :  -1565  -1522 
     12 :  -1292  -1639 
     13 :  -1643  -1604 
     14 :  -1251  -1587 
     15 :  -1458  -1653 
     16 :  -1432  -1298 
     17 :  -1112  -1629 
     18 :  -1432  -1295 
     19 :  -1431  -1388 
     20 :  -1334  -1539 
     21 :  -1484  -1499 
     22 :  -1573  -1699 
     23 :  -1621  -1445 
     24 :  -1557  -1294 
    # Map  BB_DE  Measured Current
      1 :   -134   -170 
      2 :   -139   -157 
      3 :   -135   -173 
      4 :   -168   -180 
      5 :   -144   -148 
      6 :   -167   -164 
      7 :   -140   -133 
      8 :   -142   -154 
      9 :   -124   -195 
     10 :   -176   -126 
     11 :   -166   -165 
     12 :   -142   -184 
     13 :   -180   -171 
     14 :   -135   -174 
     15 :   -158   -182 
     16 :   -154   -138 
     17 :   -120   -171 
     18 :   -162   -137 
     19 :   -159   -147 
     20 :   -149   -171 
     21 :   -160   -160 
     22 :   -177   -158 
     23 :   -180   -157 
     24 :   -168   -138 
    # Map  BB_E  Measured Voltage
      1 :  -1537  -1534 
      2 :  -1587  -1248 
      3 :  -1313  -1361 
      4 :  -1218  -1274 
      5 :  -1343  -1614 
      6 :  -1436  -1537 
      7 :  -1556  -1241 
      8 :  -1371  -1530 
      9 :  -1234  -1571 
     10 :  -1231  -1218 
     11 :  -1714  -1536 
     12 :  -1263  -1545 
     13 :  -1581  -1390 
     14 :  -1268  -1484 
     15 :  -1676  -1257 
     16 :  -1273  -1593 
     17 :  -1578  -1364 
     18 :  -1069  -1281 
     19 :  -1359  -1606 
     20 :  -1555  -1526 
     21 :  -1356  -1549 
     22 :  -1580  -1123 
     23 :  -1382  -1206 
     24 :  -1189    -24 
    # Map  BB_E  Measured Current
      1 :   -161   -163 
      2 :   -173   -130 
      3 :   -139   -149 
      4 :   -134   -139 
      5 :   -145   -172 
      6 :   -153   -170 
      7 :   -167   -136 
      8 :   -144   -166 
      9 :   -132   -168 
     10 :   -131   -128 
     11 :   -182   -163 
     12 :   -135   -164 
     13 :   -170   -144 
     14 :   -133   -151 
     15 :   -184   -125 
     16 :   -139   -151 
     17 :   -171   -150 
     18 :   -117   -131 
     19 :   -142   -159 
     20 :   -166   -166 
     21 :   -145   -160 
     22 :   -167   -115 
     23 :   -149   -122 
     24 :   -126      0 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1174 
      2 :  -1118 
      3 :  -1160 
      4 :  -1127 
      5 :  -1173 
      6 :  -1178 
      7 :  -1239 
      8 :  -1091 
      9 :  -1155 
     10 :  -1200 
     11 :  -1277 
     12 :  -1140 
     13 :  -1264 
    # Map  BB_SC_R  Measured Current
      1 :   -445 
      2 :   -422 
      3 :   -438 
      4 :   -426 
      5 :   -445 
      6 :   -445 
      7 :   -471 
      8 :   -412 
      9 :   -447 
     10 :   -454 
     11 :   -483 
     12 :   -432 
     13 :   -480 
    # Map  BB_DC  Measured Voltage
      1 :  -1611  -1610  -1651  -1648 
      2 :  -1650  -1651  -1707  -1703 
      3 :  -1642  -1641  -1692  -1690 
    # Map  BB_DC  Measured Current
      1 :    -11    -11   -103    -98 
      2 :    -18    -18   -155   -147 
      3 :    -14    -15   -129   -126 
    # Map  BB_PS_R  Measured Voltage
      1 :   -871 
      2 :   -835 
      3 :   -848 
      4 :   -849 
      5 :   -902 
      6 :   -874 
      7 :   -852 
      8 :   -859 
      9 :   -926 
     10 :   -921 
     11 :   -896 
     12 :   -891 
     13 :   -893 
     14 :   -882 
     15 :   -878 
     16 :   -974 
     17 :   -861 
     18 :   -903 
     19 :   -888 
     20 :   -902 
     21 :   -883 
     22 :   -861 
     23 :   -882 
     24 :   -905 
     25 :   -839 
     26 :   -899 
     27 :   -902 
    # Map  BB_PS_R  Measured Current
      1 :   -222 
      2 :   -215 
      3 :   -216 
      4 :   -217 
      5 :   -230 
      6 :   -225 
      7 :   -217 
      8 :   -220 
      9 :   -236 
     10 :   -235 
     11 :   -230 
     12 :   -227 
     13 :   -230 
     14 :   -224 
     15 :   -227 
     16 :   -249 
     17 :   -221 
     18 :   -232 
     19 :   -225 
     20 :   -232 
     21 :   -227 
     22 :   -219 
     23 :   -227 
     24 :   -231 
     25 :   -214 
     26 :   -230 
     27 :   -232 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1293 
      2 :  -1410 
      3 :  -1190 
      4 :  -1274 
      5 :  -1289 
      6 :  -1329 
      7 :  -1364 
      8 :  -1190 
      9 :  -1303 
     10 :  -1296 
     11 :  -1350 
     12 :  -1194 
     13 :  -1235 
    # Map  BB_SC_L  Measured Current
      1 :   -463 
      2 :   -471 
      3 :   -449 
      4 :   -435 
      5 :   -433 
      6 :   -476 
      7 :   -493 
      8 :   -428 
      9 :   -451 
     10 :   -474 
     11 :   -501 
     12 :   -452 
     13 :   -469 
    # Map  BB_CER  Measured Voltage
      1 :      5      6 
      2 :      4      3 
      3 :      5      4 
      4 :      3      5 
      5 :      4      5 
      6 :      5      4 
      7 :      4      4 
      8 :      4      5 
      9 :      3      4 
     10 :      4      5 
    # Map  BB_CER  Measured Current
      1 :      2      1 
      2 :      2      3 
      3 :      2      2 
      4 :      2      2 
      5 :      1      0 
      6 :      2      2 
      7 :      2      2 
      8 :      2      1 
      9 :      1      3 
     10 :      1      2 
    # Map  BB_PS_L  Measured Voltage
      1 :   -926 
      2 :   -917 
      3 :   -856 
      4 :   -931 
      5 :   -922 
      6 :   -915 
      7 :   -904 
      8 :   -863 
      9 :   -921 
     10 :   -946 
     11 :   -920 
     12 :   -926 
     13 :   -921 
     14 :   -980 
     15 :   -953 
     16 :   -921 
     17 :   -872 
     18 :   -891 
     19 :   -834 
     20 :   -853 
     21 :   -833 
     22 :   -828 
     23 :   -828 
     24 :   -864 
     25 :   -868 
     26 :   -830 
     27 :   -851 
    # Map  BB_PS_L  Measured Current
      1 :   -237 
      2 :   -235 
      3 :   -219 
      4 :   -238 
      5 :   -237 
      6 :   -235 
      7 :   -232 
      8 :   -221 
      9 :   -236 
     10 :   -243 
     11 :   -237 
     12 :   -238 
     13 :   -236 
     14 :   -250 
     15 :   -245 
     16 :   -236 
     17 :   -223 
     18 :   -229 
     19 :   -214 
     20 :   -218 
     21 :   -213 
     22 :   -211 
     23 :   -214 
     24 :   -220 
     25 :   -223 
     26 :   -213 
     27 :   -218 
    # Map  BB_SH  Measured Voltage
      1 :  -1325  -1298  -1284  -1585  -1741  -1737  -1354 
      2 :  -1363  -1524  -1274  -1495  -1390  -1366  -1615 
      3 :  -1323  -1151  -1654  -1565  -1543  -1563  -1521 
      4 :  -1292  -1643  -1251  -1660  -1434  -1809  -1677 
      5 :  -1458  -1432  -1112  -1432  -1522  -1455  -1511 
      6 :  -1431  -1334  -1484  -1715  -1780  -1431  -1352 
      7 :  -1573  -1621  -1557  -1518  -1707  -1565  -1653 
      8 :  -1407  -1532  -1611  -1090  -1592  -1650  -1356 
      9 :  -1381  -1494  -1232  -1420  -1595  -1243  -1474 
     10 :  -1771  -1181  -1522  -1224  -1298  -1312  -1542 
     11 :  -1639  -1604  -1587  -1653  -1399  -1479  -1242 
     12 :  -1298  -1629  -1295  -1530  -1463  -1538  -1588 
     13 :  -1388  -1539  -1499  -1699  -1278  -1436  -1579 
     14 :  -1445  -1294  -1537  -1335  -1552  -1596  -1591 
     15 :  -1587  -1313  -1218  -1343  -1545  -1472  -1447 
     16 :  -1436  -1556  -1371  -1582  -1445  -1637  -1231 
     17 :  -1234  -1231  -1714  -1263  -1420  -1509  -1650 
     18 :  -1581  -1268  -1676  -1181  -1699  -1506  -1449 
     19 :  -1273  -1578  -1069  -1359  -1443  -1688  -1384 
     20 :  -1555  -1356  -1580  -1291  -1571  -1303  -1524 
     21 :  -1382  -1189  -1534  -1248  -1578  -1396  -1267 
     22 :  -1361  -1274  -1614  -1414  -1512  -1571  -1500 
     23 :  -1537  -1241  -1530  -1571  -1653  -1086  -1328 
     24 :  -1218  -1536  -1545  -1510  -1323  -1486  -1477 
     25 :  -1390  -1484  -1257  -1593  -1320  -1228  -1595 
     26 :  -1364  -1281  -1606  -1236  -1189  -1568  -1581 
     27 :  -1526  -1549  -1123  -1206  -1160  -1427  -1503 
    # Map  BB_SH  Measured Current
      1 :   -134   -139   -135   -168   -187   -187   -143 
      2 :   -144   -167   -140   -160   -146   -145   -177 
      3 :   -142   -124   -176   -166   -163   -166   -161 
      4 :   -142   -180   -135   -176   -152   -182   -175 
      5 :   -158   -154   -120   -162   -143   -160   -155 
      6 :   -159   -149   -160   -179   -186   -146   -148 
      7 :   -177   -180   -168   -170   -181   -156   -178 
      8 :   -157   -173   -180   -118   -168   -182   -143 
      9 :   -148   -164   -133   -154   -175   -134   -157 
     10 :   -195   -126   -165   -134   -141   -140   -163 
     11 :   -184   -171   -174   -182   -152   -157   -136 
     12 :   -138   -171   -137   -161   -156   -163   -170 
     13 :   -147   -171   -160   -158   -137   -152   -167 
     14 :   -157   -138   -161   -141   -166   -175   -169 
     15 :   -173   -139   -134   -145   -164   -161   -154 
     16 :   -153   -167   -144   -170   -153   -174   -130 
     17 :   -132   -131   -182   -135   -145   -161   -178 
     18 :   -170   -133   -184   -126   -185   -163   -155 
     19 :   -139   -171   -117   -142   -156   -181   -145 
     20 :   -166   -145   -167   -143   -165   -138   -163 
     21 :   -149   -126   -163   -130   -167   -150   -135 
     22 :   -149   -139   -172   -152   -162   -168   -163 
     23 :   -170   -136   -166   -168   -177   -118   -140 
     24 :   -128   -163   -164   -166   -139   -159   -160 
     25 :   -144   -151   -125   -151   -139   -131   -171 
     26 :   -150   -131   -159   -134   -126   -172   -166 
     27 :   -166   -160   -115   -122   -121   -154   -162 
    Threshold for 'mwdc_front' is +3.503 V  (2526)
    Threshold for 'mwdc_middle' is +4.397 V  (2648)
    Threshold for 'mwdc_back' is +4.397 V  (2648)
    Threshold for 'BB_Sh' is -0.120 V  (1833)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Sh_2' is -0.080 V  (1925)
    Threshold for 'BB_Cer' is -0.300 V  (1454)
    CODA config : config TwoArmRICH
    HAPPEX run : 30470