     Run Number: 4062
     End of Run Comment:
    Run_type=Other,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Pedestal Run for RICH at HV=2150V - Happex Run 30485
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 5369         [++]: 348          [--]: 2229         [+-]: 344          [-+]: 2314         
    TIME     : [ 0]: 3.470 mins  [++]: 0.220 mins  [--]: 1.473 mins  [+-]: 0.220 mins  [-+]: 1.474 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         1.79901 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  16.49%      [++]:  14.09%      [--]:  18.04%      [+-]:  15.70%      [-+]:  15.65%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/15.0 Hz   T2[ 0] : 0.0/12.5 Hz   T3[ 0] :20.6/20.6 Hz   T4[ 0] : 0.0/8.8  Hz   T5[ 0] :12.5/12.5 Hz   T6[ 0] : 0.0/13.4 Hz   T7[ 0] : 0.0/12.5 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/14.2 Hz   T2[++] : 0.0/11.8 Hz   T3[++] :20.5/20.5 Hz   T4[++] : 0.0/8.5  Hz   T5[++] :11.8/11.8 Hz   T6[++] : 0.0/12.8 Hz   T7[++] : 0.0/11.8 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/14.8 Hz   T2[--] : 0.0/12.5 Hz   T3[--] :20.5/20.5 Hz   T4[--] : 0.0/9.2  Hz   T5[--] :12.5/12.5 Hz   T6[--] : 0.0/13.1 Hz   T7[--] : 0.0/12.5 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/15.8 Hz   T2[+-] : 0.0/13.1 Hz   T3[+-] :20.7/20.7 Hz   T4[+-] : 0.0/7.7  Hz   T5[+-] :13.1/13.1 Hz   T6[+-] : 0.0/14.2 Hz   T7[+-] : 0.0/13.1 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/15.3 Hz   T2[-+] : 0.0/12.5 Hz   T3[-+] :20.8/20.8 Hz   T4[-+] : 0.0/8.6  Hz   T5[-+] :12.5/12.5 Hz   T6[-+] : 0.0/13.6 Hz   T7[-+] : 0.0/12.5 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/3128     T2[ 0] :      0/2603     T3[ 0] :   4297/4297     T4[ 0] :      0/1837     T5[ 0] :   2603/2603     T6[ 0] :      0/2780     T7[ 0] :      0/2603     T8[ 0] :   2132/213222   
    T1[++] :      0/188      T2[++] :      0/156      T3[++] :    270/270      T4[++] :      0/112      T5[++] :    156/156      T6[++] :      0/169      T7[++] :      0/156      T8[++] :    135/13512    
    T1[--] :      0/1309     T2[--] :      0/1103     T3[--] :   1815/1815     T4[--] :      0/815      T5[--] :   1103/1103     T6[--] :      0/1161     T7[--] :      0/1103     T8[--] :    904/90489    
    T1[+-] :      0/208      T2[+-] :      0/173      T3[+-] :    273/273      T4[+-] :      0/102      T5[+-] :    173/173      T6[+-] :      0/188      T7[+-] :      0/173      T8[+-] :    135/13510    
    T1[-+] :      0/1352     T2[-+] :      0/1109     T3[-+] :   1838/1838     T4[-+] :      0/759      T5[-+] :   1109/1109     T6[-+] :      0/1199     T7[-+] :      0/1109     T8[-+] :    905/90540    
    
    AVERAGE CURRENT
    BCM x1 : 0.0172 uA  BCM x3 : 0.0132 uA  BCM x10: 0.0198 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :     1977 ppm     BCM u3 :    801.9 ppm     BCM u10:    54.17 ppm     
    BCM d1 :   -714.8 ppm     BCM d3 :     4121 ppm     BCM d10:    400.7 ppm     
    
    Target -
    BCM u1 :     1486 ppm     BCM u3 :     1611 ppm     BCM u10:    468.9 ppm     
    BCM d1 :     4164 ppm     BCM d3 :     3980 ppm     BCM d10:     2354 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:1.421E-06      BCM u3 [ 0]:5.922E-07      BCM u10[ 0]:3.771E-06      
    BCM u1 [++]:9.004E-08      BCM u3 [++]:3.757E-08      BCM u10[++]:2.39E-07       
    BCM u1 [--]:6.029E-07      BCM u3 [--]:2.509E-07      BCM u10[--]:1.6E-06        
    BCM u1 [+-]:8.969E-08      BCM u3 [+-]:3.751E-08      BCM u10[+-]:2.39E-07       
    BCM u1 [-+]:6.047E-07      BCM u3 [-+]:2.517E-07      BCM u10[-+]:1.602E-06      
    
    BCM d1 [ 0]:5.723E-06      BCM d3 [ 0]:4.91E-06       BCM d10[ 0]:4.484E-06      
    BCM d1 [++]:3.625E-07      BCM d3 [++]:3.122E-07      BCM d10[++]:2.849E-07      
    BCM d1 [--]:2.418E-06      BCM d3 [--]:2.075E-06      BCM d10[--]:1.898E-06      
    BCM d1 [+-]:3.63E-07       BCM d3 [+-]:3.097E-07      BCM d10[+-]:2.846E-07      
    BCM d1 [-+]:2.438E-06      BCM d3 [-+]:2.092E-06      BCM d10[-+]:1.907E-06      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4062 at Sun Nov 30 11:59:38 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.06
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 5892.06
    Left Arm Top VDC Current : -1.9043
    Left Arm Bottom VDC Current : 0.195312
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14994
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply current : 1011.98
    Left Arm Q2 momentum : 2.35017
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47196
    Left Arm Q3 power supply current : 935.553
    Left Arm Q3 momentum : 2.34994
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 0.0336054
    Current on Unser monitor : -7.49726
    Current on Upstream bcm : 0.0489044
    Current on Downstream bcm : 0.0183064
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.516922
    Hall C Current : 2.5076
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.06
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.06
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.6076
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.181152
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : 0.0820312
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89746
    Left VDC -DISC LVL Bottom : 3.96484
    Left VDC -DISC LVL Voltage1 : 4.97461
    Left VDC -DISC LVL Voltage2 : -5.06104
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 173
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2153.8
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.585938
    RICH Radiator Moisture : 326.074
    RICH Radiator Pressure : 9.78369
    RICH Condensor temperature : -9.23047
    RICH Gas Oxygen : 4.78516
    RICH Gas Moisture : 11.2305
    RICH Argon Flow : 0.390625
    RICH Methane Flow : 1547.95
    RICH A Volts : 3.80859
    RICH B Volts : 3.88135
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.46087
    SLI vert. size mm : 0
    SLI y position : 0.51831
    -----
    Polarized 3He Target
    RTD1 (upstream) : 41.709
    RTD2 : 55.752
    RTD3 : 155.557
    RTD4 : 77.0898
    RTD5 (downstream) : 42.4609
    RTD6 (pump cell up) : 244.512
    RTD7 (pump cell down) : 257.695
    HacAi_hpchan7: Temp at Ref. Cell : 39.043
    HacAi_hpchan8: Temp at Ref. Cell : 55.918
    HacAi_hpchan9: Temp at Ref. Cell : 38.8965
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 230.2
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.3
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9981
    ntc3_temp : 25.0417
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.62
    DDM45_2disp1_read : 6.231
    DDM45_3disp1_read : 6.231
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 111
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 11:58:49 11/30/2008nit
    haPolHe3_Last_Flip_End : 11:58:54 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : 178.554
    haPolHe3_FLIP_NMR_Mag : 22.0873
    haPolHe3_FLIP_NMR_Pol : 64.4334
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----