Privacy and Security Notice

End_of_Run_4068


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:02:07 on November 30, 2008

    Entry number 251499

    keyword=End_of_Run_4068
    ****************************
     Run Number: 4068
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production with new config CRAMS_MAX_CHAN = 240 - Happex Run 30486
     
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 104817       [++]: 13775        [--]: 37570        [+-]: 13616        [-+]: 37729        
    TIME     : [ 0]: 7.131 mins  [++]: 0.796 mins  [--]: 2.702 mins  [+-]: 0.794 mins  [-+]: 2.709 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.97889 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  14.39%      [++]:  14.65%      [--]:  14.03%      [+-]:  16.33%      [-+]:  13.99%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :37.0/77599.2 Hz   T2[ 0] : 0.0/12.8 Hz   T3[ 0] :41.7/1125.8 Hz   T4[ 0] : 0.0/36.5 Hz   T5[ 0] :37.2/37.2 Hz   T6[ 0] :161.6/16157.5 Hz   T7[ 0] : 0.0/12.9 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :44.3/92953.4 Hz   T2[++] : 0.0/12.2 Hz   T3[++] :49.6/1339.1 Hz   T4[++] : 0.0/41.9 Hz   T5[++] :41.9/41.9 Hz   T6[++] :193.4/19342.1 Hz   T7[++] : 0.0/12.7 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :34.7/72882.4 Hz   T2[--] : 0.0/12.8 Hz   T3[--] :39.2/1058.7 Hz   T4[--] : 0.0/35.0 Hz   T5[--] :35.0/35.0 Hz   T6[--] :151.8/15175.7 Hz   T7[--] : 0.0/13.0 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :44.4/93249.9 Hz   T2[+-] : 0.0/13.5 Hz   T3[+-] :49.9/1347.9 Hz   T4[+-] : 0.0/41.2 Hz   T5[+-] :44.3/44.3 Hz   T6[+-] :194.4/19437.4 Hz   T7[+-] : 0.0/13.4 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :34.6/72724.8 Hz   T2[-+] : 0.0/12.6 Hz   T3[-+] :39.2/1058.3 Hz   T4[-+] : 0.0/34.8 Hz   T5[-+] :35.8/35.8 Hz   T6[-+] :151.4/15142.1 Hz   T7[-+] : 0.0/12.7 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :  15809/33200327  T2[ 0] :      0/5457     T3[ 0] :  17839/481677   T4[ 0] :      0/15625    T5[ 0] :  15910/15910    T6[ 0] :  69128/6912891  T7[ 0] :      0/5517     T8[ 0] :   4381/438112   
    T1[++] :   2115/4442066  T2[++] :      0/583      T3[++] :   2370/63994    T4[++] :      0/2003     T5[++] :   2002/2002     T6[++] :   9243/924323   T7[++] :      0/606      T8[++] :    489/48935    
    T1[--] :   5626/11816338  T2[--] :      0/2080     T3[--] :   6356/171638   T4[--] :      0/5669     T5[--] :   5677/5677     T6[--] :  24604/2460424  T7[--] :      0/2103     T8[--] :   1660/166020   
    T1[+-] :   2116/4444306  T2[+-] :      0/645      T3[+-] :   2379/64240    T4[+-] :      0/1963     T5[+-] :   2110/2110     T6[+-] :   9263/926390   T7[+-] :      0/639      T8[+-] :    488/48804    
    T1[-+] :   5629/11822537  T2[-+] :      0/2050     T3[-+] :   6371/172037   T4[-+] :      0/5661     T5[-+] :   5815/5815     T6[-+] :  24615/2461580  T7[-+] :      0/2059     T8[-+] :   1664/166467   
    
    AVERAGE CURRENT
    BCM x1 : 9.9741 uA  BCM x3 : 9.9733 uA  BCM x10: 9.3934 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    316.9 ppm     BCM u3 :    142.6 ppm     BCM u10:    130.8 ppm     
    BCM d1 :    252.2 ppm     BCM d3 :    877.8 ppm     BCM d10:    301.5 ppm     
    
    Target -
    BCM u1 :    19.09 ppm     BCM u3 :    58.14 ppm     BCM u10:    41.41 ppm     
    BCM d1 :    109.6 ppm     BCM d3 :    54.38 ppm     BCM d10:      146 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.004309       BCM u3 [ 0]:0.004307       BCM u10[ 0]:0.003811       
    BCM u1 [++]:0.0005734      BCM u3 [++]:0.0005741      BCM u10[++]:0.0005081      
    BCM u1 [--]:0.001538       BCM u3 [--]:0.001536       BCM u10[--]:0.001358       
    BCM u1 [+-]:0.000573       BCM u3 [+-]:0.0005739      BCM u10[+-]:0.000508       
    BCM u1 [-+]:0.001538       BCM u3 [-+]:0.001536       BCM u10[-+]:0.001359       
    
    BCM d1 [ 0]:0.004225       BCM d3 [ 0]:0.004227       BCM d10[ 0]:0.004227       
    BCM d1 [++]:0.000563       BCM d3 [++]:0.0005644      BCM d10[++]:0.0005638      
    BCM d1 [--]:0.001507       BCM d3 [--]:0.001507       BCM d10[--]:0.001507       
    BCM d1 [+-]:0.0005627      BCM d3 [+-]:0.0005634      BCM d10[+-]:0.0005635      
    BCM d1 [-+]:0.001507       BCM d3 [-+]:0.001507       BCM d10[-+]:0.001507       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4068 at Sun Nov 30 16:01:49 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.08
    HALLA:dpp : 4.56511e-06
    Tiefenbach Hall A energy : 5892.08
    Left Arm Top VDC Current : 3.85742
    Left Arm Bottom VDC Current : 1.36719
    -----
    Left Arm Q1 momentum : 2.35034
    Left Arm Q1 power supply : 1768.24
    Left Arm Q1 gauss meter : -0.14992
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply current : 1011.99
    Left Arm Q2 momentum : 2.35018
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47197
    Left Arm Q3 power supply current : 935.551
    Left Arm Q3 momentum : 2.34993
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2139
    -----
    Average current of the two cavities : 11.9637
    Current on Unser monitor : 5.22208
    Current on Upstream bcm : 12.0107
    Current on Downstream bcm : 11.9168
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 12.0814
    Hall C Current : 2.4575
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.09
    Hall A momentum orbit correction (dpp) : 6.25206e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.09
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.62609
    IPM1C12.XPOS : -0.00332901
    IPM1H04A.XPOS : 0.187927
    IPM1H04A.YPOS : 1.5764
    IPM1H04B.XPOS : -1.49582
    IPM1H04B.YPOS : 1.19973
    -----
    HacL_HPE1313A:0_Ch58 : -0.181152
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : 0.0820312
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89648
    Left VDC -DISC LVL Bottom : 3.9624
    Left VDC -DISC LVL Voltage1 : 4.97363
    Left VDC -DISC LVL Voltage2 : -5.06201
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 193
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2204.2
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0.01
    RICH Radiator Oxygen : -0.78125
    RICH Radiator Moisture : 326.367
    RICH Radiator Pressure : 9.76465
    RICH Condensor temperature : -9.08398
    RICH Gas Oxygen : 5.46875
    RICH Gas Moisture : 11.3281
    RICH Argon Flow : 0.585938
    RICH Methane Flow : 1543.95
    RICH A Volts : 3.80859
    RICH B Volts : 3.88037
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0722822
    SLI Energy spread *10^5 : 1.80706
    SLI x position : 1.43106
    SLI vert. size mm : 0.124215
    SLI y position : 1.64507
    -----
    Polarized 3He Target
    RTD1 (upstream) : 42.0996
    RTD2 : 57.4707
    RTD3 : 156.826
    RTD4 : 79.0137
    RTD5 (downstream) : 42.7637
    RTD6 (pump cell up) : 244.512
    RTD7 (pump cell down) : 257.754
    HacAi_hpchan7: Temp at Ref. Cell : 38.9062
    HacAi_hpchan8: Temp at Ref. Cell : 55.7715
    HacAi_hpchan9: Temp at Ref. Cell : 38.8672
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 230
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.0
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25.0348
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.233
    DDM45_3disp1_read : 6.233
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 123
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 15:59:51 11/30/2008nit
    haPolHe3_Last_Flip_End : 15:59:56 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : 179.354
    haPolHe3_FLIP_NMR_Mag : 22.0601
    haPolHe3_FLIP_NMR_Pol : 64.3541
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----