Privacy and Security Notice

End_of_Run_4069


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:12:14 on November 30, 2008

    Entry number 251504

    keyword=End_of_Run_4069
    ****************************
     Run Number: 4069
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production with new config CRAMS_MAX_CHAN = 180 - Happex Run 30486
     RUN STOPPED FOR BIG BITE SHOWER TRIP
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 87870        [++]: 43367        [--]: 0            [+-]: 43198        [-+]: 0            
    TIME     : [ 0]: 7.604 mins  [++]: 3.756 mins  [--]: 0.017 mins  [+-]: 3.747 mins  [-+]: 0.017 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.13090 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  10.55%      [++]:  10.46%      [--]:   0.00%      [+-]:  10.66%      [-+]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :24.8/52037.5 Hz   T2[ 0] : 0.0/12.7 Hz   T3[ 0] :43.2/1165.2 Hz   T4[ 0] : 0.0/37.7 Hz   T5[ 0] :29.1/29.1 Hz   T6[ 0] :109.1/10913.3 Hz   T7[ 0] : 0.0/12.8 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :24.7/51917.6 Hz   T2[++] : 0.0/12.7 Hz   T3[++] :43.1/1163.2 Hz   T4[++] : 0.0/38.0 Hz   T5[++] :29.2/29.2 Hz   T6[++] :108.9/10889.0 Hz   T7[++] : 0.0/12.8 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] : 0.0/0.0  Hz   T4[--] : 0.0/0.0  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] : 0.0/0.0  Hz   
    T1[+-] :24.8/52014.1 Hz   T2[+-] : 0.0/12.6 Hz   T3[+-] :43.1/1164.2 Hz   T4[+-] : 0.0/37.3 Hz   T5[+-] :29.0/29.0 Hz   T6[+-] :109.1/10909.7 Hz   T7[+-] : 0.0/12.7 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] : 0.0/0.0  Hz   T4[-+] : 0.0/0.0  Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :  11305/23742358  T2[ 0] :      0/5775     T3[ 0] :  19689/531612   T4[ 0] :      0/17194    T5[ 0] :  13295/13295    T6[ 0] :  49792/4979260  T7[ 0] :      0/5819     T8[ 0] :   4672/467205   
    T1[++] :   5570/11698658  T2[++] :      0/2855     T3[++] :   9707/262096   T4[++] :      0/8570     T5[++] :   6569/6569     T6[++] :  24536/2453621  T7[++] :      0/2876     T8[++] :   2307/230739   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :      0/0        T4[--] :      0/0        T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :      0/0        
    T1[+-] :   5568/11693821  T2[+-] :      0/2842     T3[+-] :   9693/261734   T4[+-] :      0/8382     T5[+-] :   6518/6518     T6[+-] :  24527/2452718  T7[+-] :      0/2853     T8[+-] :   2302/230216   
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :      0/0        T4[-+] :      0/0        T5[-+] :      0/0        T6[-+] :      0/0        T7[-+] :      0/0        T8[-+] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 10.3532uA  BCM x3 : 10.3528uA  BCM x10: 9.7502 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    291.9 ppm     BCM u3 :    116.5 ppm     BCM u10:    105.5 ppm     
    BCM d1 :    216.6 ppm     BCM d3 :    823.8 ppm     BCM d10:      266 ppm     
    
    Target -
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.004771       BCM u3 [ 0]:0.004769       BCM u10[ 0]:0.004219       
    BCM u1 [++]:0.002351       BCM u3 [++]:0.00235        BCM u10[++]:0.002079       
    BCM u1 [--]:0              BCM u3 [--]:0              BCM u10[--]:0              
    BCM u1 [+-]:0.00235        BCM u3 [+-]:0.002349       BCM u10[+-]:0.002078       
    BCM u1 [-+]:0              BCM u3 [-+]:0              BCM u10[-+]:0              
    
    BCM d1 [ 0]:0.004676       BCM d3 [ 0]:0.004678       BCM d10[ 0]:0.004678       
    BCM d1 [++]:0.002304       BCM d3 [++]:0.002308       BCM d10[++]:0.002305       
    BCM d1 [--]:0              BCM d3 [--]:0              BCM d10[--]:0              
    BCM d1 [+-]:0.002303       BCM d3 [+-]:0.002304       BCM d10[+-]:0.002304       
    BCM d1 [-+]:0              BCM d3 [-+]:0              BCM d10[-+]:0              
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4069 at Sun Nov 30 16:11:52 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.1
    HALLA:dpp : 7.14542e-06
    Tiefenbach Hall A energy : 5892.1
    Left Arm Top VDC Current : -1.66016
    Left Arm Bottom VDC Current : 2.49023
    -----
    Left Arm Q1 momentum : 2.35034
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14994
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply current : 1011.98
    Left Arm Q2 momentum : 2.35017
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47195
    Left Arm Q3 power supply current : 935.548
    Left Arm Q3 momentum : 2.34992
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 12.0289
    Current on Unser monitor : 4.69577
    Current on Upstream bcm : 12.0644
    Current on Downstream bcm : 11.9935
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 11.9845
    Hall C Current : 2.65388
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.08
    Hall A momentum orbit correction (dpp) : 4.78174e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.08
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.62765
    IPM1C12.XPOS : 0.00134036
    IPM1H04A.XPOS : 0.199962
    IPM1H04A.YPOS : 1.58258
    IPM1H04B.XPOS : -1.48335
    IPM1H04B.YPOS : 1.20169
    -----
    HacL_HPE1313A:0_Ch58 : -0.182129
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : 0.0820312
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.896
    Left VDC -DISC LVL Bottom : 3.96094
    Left VDC -DISC LVL Voltage1 : 4.97314
    Left VDC -DISC LVL Voltage2 : -5.06348
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 194
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2204.6
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201.4
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -1.26953
    RICH Radiator Moisture : 321.973
    RICH Radiator Pressure : 9.75146
    RICH Condensor temperature : -9.03516
    RICH Gas Oxygen : 6.34766
    RICH Gas Moisture : 11.4258
    RICH Argon Flow : 0.585938
    RICH Methane Flow : 1525.49
    RICH A Volts : 3.80908
    RICH B Volts : 3.88184
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0758845
    SLI Energy spread *10^5 : 1.89711
    SLI x position : 1.43106
    SLI vert. size mm : 0.109935
    SLI y position : 1.65258
    -----
    Polarized 3He Target
    RTD1 (upstream) : 40.791
    RTD2 : 57.2363
    RTD3 : 156.816
    RTD4 : 79.043
    RTD5 (downstream) : 43.0664
    RTD6 (pump cell up) : 244.277
    RTD7 (pump cell down) : 257.52
    HacAi_hpchan7: Temp at Ref. Cell : 39.0527
    HacAi_hpchan8: Temp at Ref. Cell : 56.0059
    HacAi_hpchan9: Temp at Ref. Cell : 39.043
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 230.1
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.0
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 24.9635
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.232
    DDM45_3disp1_read : 6.232
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 123
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 15:59:51 11/30/2008nit
    haPolHe3_Last_Flip_End : 15:59:56 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : 179.354
    haPolHe3_FLIP_NMR_Mag : 22.0601
    haPolHe3_FLIP_NMR_Pol : 64.3541
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----