Privacy and Security Notice

End_of_Run_4070


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 17:13:25 on November 30, 2008

    Entry number 251510

    keyword=End_of_Run_4070
    ****************************
     Run Number: 4070
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production back to the standard config CRAMS_MAX_CHAN = 120 - Happex Run 30486
     
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 997543       [++]: 225304       [--]: 264814       [+-]: 225889       [-+]: 264926       
    TIME     : [ 0]: 59.121 mins  [++]: 13.117 mins  [--]: 15.994 mins  [+-]: 13.085 mins  [-+]: 16.042 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.96687 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   9.65%      [++]:   9.84%      [--]:   9.55%      [+-]:   9.74%      [-+]:   9.56%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :40.5/85030.9 Hz   T2[ 0] : 0.0/12.8 Hz   T3[ 0] :45.5/1227.6 Hz   T4[ 0] : 0.0/39.3 Hz   T5[ 0] :39.8/39.8 Hz   T6[ 0] :176.9/17688.0 Hz   T7[ 0] : 0.0/13.0 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :41.4/86889.4 Hz   T2[++] : 0.0/12.8 Hz   T3[++] :46.3/1250.8 Hz   T4[++] : 0.0/39.9 Hz   T5[++] :40.4/40.4 Hz   T6[++] :180.8/18076.8 Hz   T7[++] : 0.0/13.0 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :39.6/83217.0 Hz   T2[--] : 0.0/12.8 Hz   T3[--] :44.5/1202.7 Hz   T4[--] : 0.0/38.7 Hz   T5[--] :38.9/38.9 Hz   T6[--] :173.3/17331.1 Hz   T7[--] : 0.0/13.0 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :41.5/87162.1 Hz   T2[+-] : 0.0/12.8 Hz   T3[+-] :46.6/1258.6 Hz   T4[+-] : 0.0/40.0 Hz   T5[+-] :40.9/40.9 Hz   T6[+-] :181.1/18112.9 Hz   T7[+-] : 0.0/13.0 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :39.5/83051.3 Hz   T2[-+] : 0.0/12.7 Hz   T3[-+] :44.5/1200.7 Hz   T4[-+] : 0.0/38.5 Hz   T5[-+] :38.9/38.9 Hz   T6[-+] :172.7/17274.4 Hz   T7[-+] : 0.0/12.9 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] : 143632/301627626  T2[ 0] :      0/45343    T3[ 0] : 161285/4354717  T4[ 0] :      0/139349   T5[ 0] : 141042/141042   T6[ 0] : 627441/62744145  T7[ 0] :      0/45981    T8[ 0] :  36324/3632404  
    T1[++] :  32564/68384926  T2[++] :      0/10100    T3[++] :  36461/984458   T4[++] :      0/31430    T5[++] :  31806/31806    T6[++] : 142270/14227088  T7[++] :      0/10203    T8[++] :   8059/805923   
    T1[--] :  38028/79859237  T2[--] :      0/12284    T3[--] :  42746/1154168  T4[--] :      0/37147    T5[--] :  37323/37323    T6[--] : 166317/16631757  T7[--] :      0/12437    T8[--] :   9826/982682   
    T1[+-] :  32586/68432309  T2[+-] :      0/10058    T3[+-] :  36599/988177   T4[+-] :      0/31397    T5[+-] :  32109/32109    T6[+-] : 142207/14220715  T7[+-] :      0/10195    T8[+-] :   8039/803958   
    T1[-+] :  38066/79939120  T2[-+] :      0/12265    T3[-+] :  42802/1155666  T4[-+] :      0/37072    T5[-+] :  37433/37433    T6[-+] : 166270/16627039  T7[-+] :      0/12399    T8[-+] :   9856/985628   
    
    AVERAGE CURRENT
    BCM x1 : 10.9237uA  BCM x3 : 10.9232uA  BCM x10: 10.2871uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    191.9 ppm     BCM u3 :    19.48 ppm     BCM u10:    8.726 ppm     
    BCM d1 :    130.8 ppm     BCM d3 :    741.5 ppm     BCM d10:    174.2 ppm     
    
    Target -
    BCM u1 :    82.04 ppm     BCM u3 :    115.3 ppm     BCM u10:      103 ppm     
    BCM d1 :    166.5 ppm     BCM d3 :      112 ppm     BCM d10:    213.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.03913        BCM u3 [ 0]:0.03912        BCM u10[ 0]:0.0346         
    BCM u1 [++]:0.008871       BCM u3 [++]:0.008867       BCM u10[++]:0.007844       
    BCM u1 [--]:0.01037        BCM u3 [--]:0.01037        BCM u10[--]:0.009168       
    BCM u1 [+-]:0.008867       BCM u3 [+-]:0.008867       BCM u10[+-]:0.007844       
    BCM u1 [-+]:0.01037        BCM u3 [-+]:0.01037        BCM u10[-+]:0.00917        
    
    BCM d1 [ 0]:0.03836        BCM d3 [ 0]:0.03838        BCM d10[ 0]:0.03838        
    BCM d1 [++]:0.008698       BCM d3 [++]:0.008713       BCM d10[++]:0.008704       
    BCM d1 [--]:0.01016        BCM d3 [--]:0.01017        BCM d10[--]:0.01017        
    BCM d1 [+-]:0.008695       BCM d3 [+-]:0.0087         BCM d10[+-]:0.008701       
    BCM d1 [-+]:0.01017        BCM d3 [-+]:0.01017        BCM d10[-+]:0.01017        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4070 at Sun Nov 30 17:13:07 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.08
    HALLA:dpp : 4.14744e-06
    Tiefenbach Hall A energy : 5892.08
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 2.19727
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.24
    Left Arm Q1 gauss meter : -0.14991
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply current : 1011.98
    Left Arm Q2 momentum : 2.35017
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47197
    Left Arm Q3 power supply current : 935.549
    Left Arm Q3 momentum : 2.34993
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 11.8891
    Current on Unser monitor : 3.54119
    Current on Upstream bcm : 11.8941
    Current on Downstream bcm : 11.8841
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 12.001
    Hall C Current : 4.52516
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.07
    Hall A momentum orbit correction (dpp) : 1.59215e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.07
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.62049
    IPM1C12.XPOS : -0.0111964
    IPM1H04A.XPOS : 0.175028
    IPM1H04A.YPOS : 1.57921
    IPM1H04B.XPOS : -1.51415
    IPM1H04B.YPOS : 1.20025
    -----
    HacL_HPE1313A:0_Ch58 : -0.182617
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : 0.0825195
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89502
    Left VDC -DISC LVL Bottom : 3.95801
    Left VDC -DISC LVL Voltage1 : 4.97217
    Left VDC -DISC LVL Voltage2 : -5.06348
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 198
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2203.8
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0.01
    RICH Radiator Oxygen : -0.976562
    RICH Radiator Moisture : 325.684
    RICH Radiator Pressure : 9.73828
    RICH Condensor temperature : -9.13281
    RICH Gas Oxygen : 5.27344
    RICH Gas Moisture : 11.4258
    RICH Argon Flow : 0.390625
    RICH Methane Flow : 1507.03
    RICH A Volts : 3.80811
    RICH B Volts : 3.88135
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0632908
    SLI Energy spread *10^5 : 1.58227
    SLI x position : 1.43106
    SLI vert. size mm : 0.114968
    SLI y position : 1.64507
    -----
    Polarized 3He Target
    RTD1 (upstream) : 42.1973
    RTD2 : 57.168
    RTD3 : 156.318
    RTD4 : 79.1895
    RTD5 (downstream) : 42.4707
    RTD6 (pump cell up) : 244.219
    RTD7 (pump cell down) : 257.344
    HacAi_hpchan7: Temp at Ref. Cell : 38.8086
    HacAi_hpchan8: Temp at Ref. Cell : 56.2402
    HacAi_hpchan9: Temp at Ref. Cell : 38.9648
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.3
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.8
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.232
    DDM45_3disp1_read : 6.232
    ----
    haPolHe3_Spin_State : -1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 126
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 17:00:07 11/30/2008nit
    haPolHe3_Last_Flip_End : 17:00:12 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : -1.23495
    haPolHe3_FLIP_NMR_Mag : 22.386
    haPolHe3_FLIP_NMR_Pol : 65.3047
    HaGenTargSpin1 : enabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.37
    ----