Privacy and Security Notice

End_of_Run_4072


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:21:42 on November 30, 2008

    Entry number 251519

    keyword=End_of_Run_4072
    ****************************
     Run Number: 4072
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production run, Happex Run 30487
     
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 996988       [++]: 177286       [--]: 312787       [+-]: 176766       [-+]: 313256       
    TIME     : [ 0]: 61.482 mins  [++]: 10.496 mins  [--]: 19.749 mins  [+-]: 10.472 mins  [-+]: 19.812 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.96985 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   9.71%      [++]:   9.79%      [--]:   9.70%      [+-]:   9.87%      [-+]:   9.61%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :38.8/81543.2 Hz   T2[ 0] : 0.0/12.7 Hz   T3[ 0] :43.8/1181.8 Hz   T4[ 0] : 0.0/38.3 Hz   T5[ 0] :38.5/38.5 Hz   T6[ 0] :169.5/16954.5 Hz   T7[ 0] : 0.0/12.9 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :40.6/85248.6 Hz   T2[++] : 0.0/12.9 Hz   T3[++] :45.6/1232.0 Hz   T4[++] : 0.0/39.9 Hz   T5[++] :39.9/39.9 Hz   T6[++] :177.3/17725.3 Hz   T7[++] : 0.0/12.9 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :37.8/79396.7 Hz   T2[--] : 0.0/12.6 Hz   T3[--] :42.7/1152.0 Hz   T4[--] : 0.0/37.4 Hz   T5[--] :37.9/37.9 Hz   T6[--] :165.2/16522.2 Hz   T7[--] : 0.0/12.8 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :40.7/85514.1 Hz   T2[+-] : 0.0/12.6 Hz   T3[+-] :45.8/1235.8 Hz   T4[+-] : 0.0/39.6 Hz   T5[+-] :39.5/39.5 Hz   T6[+-] :177.5/17753.6 Hz   T7[+-] : 0.0/12.8 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :37.7/79222.2 Hz   T2[-+] : 0.0/12.9 Hz   T3[-+] :42.6/1150.5 Hz   T4[-+] : 0.0/37.5 Hz   T5[-+] :37.7/37.7 Hz   T6[-+] :164.8/16476.7 Hz   T7[-+] : 0.0/13.0 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] : 143240/300805959  T2[ 0] :      0/46979    T3[ 0] : 161460/4359443  T4[ 0] :      0/141281   T5[ 0] : 141982/141982   T6[ 0] : 625436/62543694  T7[ 0] :      0/47599    T8[ 0] :  37774/3777451  
    T1[++] :  25565/53688323  T2[++] :      0/8124     T3[++] :  28736/775898   T4[++] :      0/25135    T5[++] :  25149/25149    T6[++] : 111631/11163159  T7[++] :      0/8146     T8[++] :   6449/644900   
    T1[--] :  44801/94082534  T2[--] :      0/14944    T3[--] :  50560/1365124  T4[--] :      0/44259    T5[--] :  44875/44875    T6[--] : 195782/19578294  T7[--] :      0/15170    T8[--] :  12134/1213407  
    T1[+-] :  25584/53727638  T2[+-] :      0/7946     T3[+-] :  28756/776415   T4[+-] :      0/24888    T5[+-] :  24797/24797    T6[+-] : 111543/11154381  T7[+-] :      0/8072     T8[+-] :   6433/643369   
    T1[-+] :  44844/94174277  T2[-+] :      0/15286    T3[-+] :  50653/1367651  T4[-+] :      0/44549    T5[-+] :  44792/44792    T6[-+] : 195864/19586431  T7[-+] :      0/15420    T8[-+] :  12172/1217265  
    
    AVERAGE CURRENT
    BCM x1 : 10.5052uA  BCM x3 : 10.5049uA  BCM x10: 9.8934 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    242.8 ppm     BCM u3 :    58.01 ppm     BCM u10:    48.27 ppm     
    BCM d1 :    165.7 ppm     BCM d3 :    775.7 ppm     BCM d10:    211.9 ppm     
    
    Target -
    BCM u1 :    114.9 ppm     BCM u3 :    153.5 ppm     BCM u10:    141.2 ppm     
    BCM d1 :    206.8 ppm     BCM d3 :    152.9 ppm     BCM d10:      250 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.03916        BCM u3 [ 0]:0.03915        BCM u10[ 0]:0.03463        
    BCM u1 [++]:0.00698        BCM u3 [++]:0.006979       BCM u10[++]:0.006174       
    BCM u1 [--]:0.01227        BCM u3 [--]:0.01226        BCM u10[--]:0.01084        
    BCM u1 [+-]:0.006977       BCM u3 [+-]:0.006978       BCM u10[+-]:0.006174       
    BCM u1 [-+]:0.01227        BCM u3 [-+]:0.01226        BCM u10[-+]:0.01085        
    
    BCM d1 [ 0]:0.03834        BCM d3 [ 0]:0.03835        BCM d10[ 0]:0.03836        
    BCM d1 [++]:0.006837       BCM d3 [++]:0.00685        BCM d10[++]:0.006843       
    BCM d1 [--]:0.012          BCM d3 [--]:0.01201        BCM d10[--]:0.01201        
    BCM d1 [+-]:0.006835       BCM d3 [+-]:0.006839       BCM d10[+-]:0.00684        
    BCM d1 [-+]:0.01201        BCM d3 [-+]:0.01201        BCM d10[-+]:0.01202        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4072 at Sun Nov 30 19:21:23 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.1
    HALLA:dpp : 7.47077e-06
    Tiefenbach Hall A energy : 5892.1
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 1.41602
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14993
    Left Arm Q2 gauss meter : 0.5323
    Left Arm Q2 power supply current : 1011.99
    Left Arm Q2 momentum : 2.35018
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47196
    Left Arm Q3 power supply current : 935.552
    Left Arm Q3 momentum : 2.34993
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 11.935
    Current on Unser monitor : 4.46684
    Current on Upstream bcm : 11.9458
    Current on Downstream bcm : 11.9241
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 11.9872
    Hall C Current : 3.07641
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.1
    Hall A momentum orbit correction (dpp) : 7.47077e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.1
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.61562
    IPM1C12.XPOS : 0.0278227
    IPM1H04A.XPOS : 0.18336
    IPM1H04A.YPOS : 1.57593
    IPM1H04B.XPOS : -1.50067
    IPM1H04B.YPOS : 1.20692
    -----
    HacL_HPE1313A:0_Ch58 : -0.182617
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : 0.0825195
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89697
    Left VDC -DISC LVL Bottom : 3.96387
    Left VDC -DISC LVL Voltage1 : 4.97461
    Left VDC -DISC LVL Voltage2 : -5.0625
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 204
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2204.2
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.878906
    RICH Radiator Moisture : 322.07
    RICH Radiator Pressure : 9.75049
    RICH Condensor temperature : -9.03516
    RICH Gas Oxygen : 7.12891
    RICH Gas Moisture : 11.1328
    RICH Argon Flow : 0.390625
    RICH Methane Flow : 1530.18
    RICH A Volts : 3.80762
    RICH B Volts : 3.88184
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0855338
    SLI Energy spread *10^5 : 2.13835
    SLI x position : 1.43106
    SLI vert. size mm : 0.115174
    SLI y position : 1.65258
    -----
    Polarized 3He Target
    RTD1 (upstream) : 42.4023
    RTD2 : 57.7148
    RTD3 : 157.5
    RTD4 : 79.3652
    RTD5 (downstream) : 42.998
    RTD6 (pump cell up) : 244.395
    RTD7 (pump cell down) : 257.812
    HacAi_hpchan7: Temp at Ref. Cell : 38.7891
    HacAi_hpchan8: Temp at Ref. Cell : 56.4648
    HacAi_hpchan9: Temp at Ref. Cell : 38.8379
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.4
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.3
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.233
    DDM45_3disp1_read : 6.233
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 133
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 19:20:43 11/30/2008nit
    haPolHe3_Last_Flip_End : 19:20:48 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : 178.637
    haPolHe3_FLIP_NMR_Mag : 22.3023
    haPolHe3_FLIP_NMR_Pol : 65.0604
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----